This manual describes the configuration of the Wireless Enterprise 
WEA524i and its installation procedures.

WEA524i (Indoor) Quick Installation Manual

Introduction

 What is the WEA524i? 

The Samsung WEA524i is an Access Point (AP) which has been designed for 
connecting a UE such as a smart phone, a tablet PC or a laptop that supports the 
wireless LAN to a wired network. 
WEA524i supports the following features:
- IEEE 802.11a/b/g/n/ac standards
- PoE (Power over Ethernet) IEEE 802.3af/802.3at
- 4 × 4 MU-MIMO (Multi User-Multiple Input Multiple Output)
- 2.4 GHz and 5 GHz concurrent radios

 Components 

After unpacking the WEA524i, confirm that all of the following items have been included.

WEA524i

Package Contents

Mounting Bracket

5 M3 × L6 screws

(Including 1 spare)

Installation Manual

Security Torx (T10) Screw

Plastic 4 anchors

4 M4 × L28 screws

- It is recommended to keep all packaging materials and the box.
- The power adaptor is sold separately. If necessary, contact the retailer.

Functions

 

Front View

Status LED

 

Rear View

 

DC Input

Ethernet Port (PoE)

Ethernet Port

Factory Reset Switch

USB Port

Console Port

 

Interface

Port Name

Description

Status LED

Displays the operational status of the WEA524i via LED.

DC Input

This is for connecting the power adapter.

Ethernet Port (PoE) 

Supports 1000 BASE-T Gigabit Ethernet and PoE IEEE 
802.3af/802.3at.

Ethernet Port 

Supports 1000 BASE-T Gigabit Ethernet.

Console Port 

Used for checking the operational status of the WEA524i 
and for CLI input.

Factory Reset Switch

Used to reset the WEA524i to the initial factory settings.

USB Port

Supports USB 2.0

Status LED

LED

Status 

Description 

System start 
status

White On 

Initial LED status

Blue On

Device reset and test in progress

Red On

Booting failure (Device reset failure)

Normal operation 
status

Green On 

When there is no connected wireless UE

Blue On 

When there is a connected wireless UE

Upgrade 

Green blinking 

Software upgrade in progress

Error status 

Red blinking 

Physical connection error of network

Yellow blinking

IP address conflict

Violet blinking 

Dynamic IP address allocation failure

Red, green and off 
repeated

Wireless interface error

Installation

The WEA524i can be installed on ceilings or walls.
Please confirm that all of the components have been included before installation.

 Before Installation 

Safety Requirements

Carefully observe the following safety warnings in order to avoid the risk of damage or 
injury. For safe use, make sure to be well-informed. 

- There is a risk of electrical shock. Make sure that the 

power is turned off during installation. Do not proceed 
with the installation if there is any electrical current 
leaking. It may cause a serious electric shock.

- Wear anti-static gloves or take an appropriate action to 

prevent ESD when handling the product.

- Do not connect a phone line to an Ethernet port.  

This may damage the product.

- This product must be connected to a power supply 

in compliance with IEEE 802.3af/at or connected to a 
limited power supply in compliance with IEC/EN/UL 
60950-1.

- This product must be installed or removed by only appropriately trained 

service personnel.

- This product operates in the Safety Extra Low Voltage (SELV) state in 

compliance with IEC/EN/UL 60950-1.

- All the connected equipment including this product must be installed 

inside of the same building.  
For more details, refer to the Environment A of IEEE 802.3af/at standards.

- During installation, this product must be installed at least 3 m or more 

apart from WiMAX/3G/4G repeater or antenna.

Installation Instructions

The following instructions must be carefully observed during installation. 
- The system must be installed in a place that is easily accessible for product installation, 

cable connections, and maintenance.

- The PoE cable must be always installed away from any electrical interference source 

such as power lines, fluorescent lights or transmitters.

- The PoE cable must be CAT 5e or higher.
- When PoE is unavailable, a power adapter (sold separately) can be used.  

The 3-pin (including ground) power socket that supplies 100~240 V AC, 50~60 Hz 
must be located within 2 m from each equipment and the power must be supplied 
through an independent circuit breaker.  
It is recommended to use the equipment that uses a filter or a surge protector.

 Installation on Ceilings (When the ceiling type is T-bar)

- When incorrectly installed on the ceiling, the WEA524i may drop onto a 

person or equipment. Therefore, make sure to fix it firmly.

- If the ceiling type is not T-bar, please refer to the ‘Installation Manual’ 

provided separately. For this installation manual, please contact the 
dealer. 

1.

Remove the holding tape that was attached to fix the ceiling clip.

                         

Holding tape

 

Отзывы: