4.7  Release the left and right 12W adapters to install the 

continuity strap. 

Note

:  Make  sure  the  PVC  tape  has  no  contact  with  gel 

port. 

 

 

4.8  Check if all cable outer jacket ends  contact the port 

end-face.   

 

4.9  Close the 12W adapter and secure the 12W cable in 

drop port and 26W cable by a tie wrap as shown.   

Note:  The  tie  wrap  knot  is  located  at  the  closure 

outer surface. (refer to 4.10) 

 

 

4.10  Tie wrap knot location.   

 

Closing of the closure 

5.1  Close the closure and check if the screws are in the 

right position.   

   

 

5.2  Close the wedge until a click. 

 

 

5.3  Tighten the screws at closure two sides to close the 

closure. 

 

 

 

Содержание MDCC

Страница 1: ...re external dimension 370 135 50mm Cable outer diameter 1W 1 way cable 7 2mm and 9 0mm 12W 12 way cable 23mm 26W 26 way cable 36mm 4W 4 way cable 14 8mm 7W 7 way cable 18mm 1 2 Kit content 4 Way kit 7 way kit 1 Closure body 2 Wedge 3 Dummy rods 4 6 port gel block 5 12W drop gel block 6 6 port gel block cover 7 12W adapter left 8 12W adapter right 9 Tie wraps 10 Cleaning tissue 11 Continuity strap ...

Страница 2: ... 7 way cable in drop port 2 Cable preparation 2 1 Remove the cable sheath and cut the micro ducts for each cable type as indicated below 1 way 2 1 1 1 way cable 9mm 2 1 2 1 way cable 7 2mm 2 1 2 1 Remove 150mm 7 2mm jacket and as below 2 1 2 2 Remove 50mm rib on 7 2mm jacket as below make sure no further damage for 7 2mm outer jacket 12 way cable 2 1 3 For 12W cable used in Application 2 220mm 320...

Страница 3: ...Application 3 3 Closure installation 3 1 Push the clip and then use the screw driver to open the closure 3 2 1W cable installation 3 2 1 Install the 3pcs 1W cables or dummy rods onto the 6 port gel block underside 3 2 1 1 For 9 0mm tube as below Note Make sure the outer jacket contacts gel port end surface as shown 3 2 1 2 For 7 2mm tube as blow Note Make sure the outer jacket exceed gel port end ...

Страница 4: ...ote Fit the dummy rod tabs at the slots as shown 3 2 4 Install the 6 port gel block cover Click in as shown 3 3 4W 7W cable installation 3 3 1 Install the 1pc 1W cables or dummy rods onto the 4 way gel block underside Note Make sure the outer jacket contacts gel port end surface as shown 3 3 2 Install the 4W or 7W gel block assembly onto the closure with hooking the gel block two sides as shown ...

Страница 5: ...is suitable for the original gel block in closure cover 3 4 12W cable installation 12W cable in drop cable port 3 4 1 Install the 12W drop gel block with click two snaps 3 4 2 Position the cable onto the closure Note Always make sure the outer jacket end meets the gel port surface 12W cable in main cable port 3 4 3 Install the left and right 12W adapters onto the closure 3 4 4 Position the 12W cab...

Страница 6: ... as shown 4 Micro Duct Connections 4 1 Install connectors from bottom side micro ducts 4 2 Install the connectors onto the feeder cable micro ducts 4 3 Mark the drop cable at the connector 4 4 Cut the micro ducts at the mark 4 5 Connect the micro ducts with connectors 4 6 Repeat steps 4 1 4 5 to connect all the feeder micro ducts to drop micro ducts ...

Страница 7: ... 4 9 Close the 12W adapter and secure the 12W cable in drop port and 26W cable by a tie wrap as shown Note The tie wrap knot is located at the closure outer surface refer to 4 10 4 10 Tie wrap knot location 5 Closing of the closure 5 1 Close the closure and check if the screws are in the right position 5 2 Close the wedge until a click 5 3 Tighten the screws at closure two sides to close the closu...

Страница 8: ...ale CommScope expressly disclaims any implied warranty regarding the information contained herein including but not limited to the implied warranties of merchantability or fitness for a particular purpose 2017 CommScope Inc All rights reserved This product is covered by one or more U S patents or their foreign equivalents For patents see www commscope com ProductPatent ProductPatent aspx To obtain...

Отзывы: