![CommScope FST-T Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/commscope/fst-t/fst-t_installation-instructions-manual_2643851005.webp)
Page 5 of 10
© 2019 CommScope, Inc. All Rights Reserved
6.4.
HMFOC Plug Fiber Layout and Alignment to Drop Cable Ports
Figure 7
BLU ORAGRE BRO SLA WHI RED BLA YEL VIO ROS AQU
4
1
5
2
2
1
7
6
7
3
8
9
10
12
3
4
5
6
3
4
1
2
5
6
1
2
3
4
1
2
8
11
6.5.
Connecting Feeder Cable to FST-T HMFOC Cable
Remove the dust caps, inspect and clean the feeder cable connectors. Connect the feeder cable to the
FST-T ensuring both key-ways line up. Finger tighten locking threads to secure.
Figure 8
6.6.
Installing FST-T in Hand Hole / Pit
FST-T can be fixed to the side of a hand hole/pit using self-tapping screw (not included in kit).