Maintenance of FST-R Terminals

Maintenance for the FST-R terminal is limited to cleaning the hardened adapters as needed to maintain optimal   

performance.

9.1. 

DLX Cable Connector and adapter Cleaning Procedure

Clean both the optical port adapter and the drop cable connector (requires accessory kit FHD-ACC-CLNKIT1) as specified in 

ADCP-96-163. 

9.1.1. 

 

DLX connector cleaning

9.1.1.1.  Examine the end of the drop cable connector, note the position of the protrusions on the connector. 

9.1.1.2.  Locate the cleaning tape cassette that is provided with the cleaning kit.

9.1.1.3.  Open the tape shutter by squeezing the lever on the underside of the cassette and then keep the shutter  

   

open by continuing to squeeze the lever. 

9.1.1.4. Hold connector facing you with the protrusions  

 

 

 

perpendicular to the length of the cleaning cassette, tilt  

 

 

the connector to the right (no more than 8-degrees) this  

 

 

places the connector in the correct position for cleaning. 

 

Note: The drop cable connector uses angled SC type 

connectors. Make sure the connector end-face is point-

ing in the correct direction before starting the cleaning 

motion. 

9.1.1.5. With light pressure, slide the connector end-face once  

 

 

across the tape in the direction shown using a smooth  

 

 

linear motion. Do not press too hard and do not repeat  

 

 

the cleaning motion with the same tape. 

9.1.1.6. Release the lever on the underside of the cassette to  

 

 

close the tape shutter. 

9.1.1.7. Repeat Step 9.1.1.3 through Step 9.1.1.6

 

until the    

 

 

connector has been cleaned three times.

9.1.2. 

 

DLX adapter cleaning

9.1.2.1.  Locate the dry swabs that are provided with the connector/adapter cleaning kit.
9.1.2.2.  Insert a dry swab into the adapter as shown on picture below.

 

                          Note: Do not apply alcohol to the swab or the adapter.

9.1.2.3.  While applying light pressure against the connector end-face, rotate the dry swab 360º three times.
9.1.2.4.  Dispose of the dry swab after use.
9.1.2.5.  When connector end-face and adapter are clean, install the drop cable connector into the optical port.

CASSETTE

CLEANING

TAPE

DIRECTION

OF CONNECTOR

MOTION

ANGLED CONNECTOR

DETAIL DRAWING

PROTRUSIONS

PROTRUSIONS

Cleaning Tools

Содержание FST-R

Страница 1: ...al product information The FST R is a compact sealed terminal with hardened connectivity for reliable plug n play distribution to customer premises Featuring pre connectorized hardened full size or DLX adapter drops and a round loose tube feeder cable dia5 5mm to splice CommScope s FST R enables FTTH deployment in brown field and green field applications Primarily designed for hand hole applicatio...

Страница 2: ...alled in a site satisfying the following conditions 3 1 Avoid locations where temperature is too high or low FST R normally operates in an environment with the following conditions Operating temperature 20ºC 65ºC 3 2 Keep the product surroundings clean and dust free both during and after installation 4 Required Tools Standard tools to mount the FST R and cable preparation tools for splicing fibers...

Страница 3: ...t Dimension mm 6 2 Installing FST R in Hand Hole Pit wall pole 6 2 1 FST R can be fixed to the side of a hand hole pit wall using self tapping screw not included in kit 6 2 2 Ensure FST R is located in the pit with feeder situated below the customer ports to allow easy installer access ...

Страница 4: ...eeder cable to FST R Remove the cable jacket using the correct tools and RIP cord in the cable and handle the cable per standard local practice in the previous network element ex enclosure terminal or hub Cable OD 5 5 mm Loose tube OD 2 5 mm 8 Installing Drop cable Ensure you remove the dust caps Use the 216B key tool accessory to unscrew the dust cap from the optical port inspect and clean them i...

Страница 5: ... that both dust caps will stay clean when not in use 8 2 Full size hardened connector 8 2 1 Align the Full size hardened connectors as shown in Figure below The pointer on the drop cable connector should line up with the notch on the FST R adapter Insert the drop cable connector into the optical port and tighten coupling nut until finger tight 8 2 2 Thread the optical port dust cap into the drop c...

Страница 6: ...aning Note The drop cable connector uses angled SC type connectors Make sure the connector end face is point ing in the correct direction before starting the cleaning motion 9 1 1 5 With light pressure slide the connector end face once across the tape in the direction shown using a smooth linear motion Do not press too hard and do not repeat the cleaning motion with the same tape 9 1 1 6 Release t...

Страница 7: ...nnector end face once across the tape in the direction shown using a smooth linear motion Do not press too hard and do not repeat the cleaning motion with the same tape 9 2 1 6 Release the lever on the underside of the cassette to close the tape shutter 9 2 1 7 Repeat Step 9 2 1 3 through Step 9 2 1 6 until the connector has been cleaned three times 9 2 2 Full size hardened adapter cleaning 9 2 2 ...

Страница 8: ... a number of CommScope s facilities across the globe certified in accordance with international standards including ISO 9001 TL 9000 and ISO 14001 Further information regarding CommScope s commitment can be found at www commscope com About Us Corporate Responsibility and Sustainability 11 Contact information Visit our website or contact your local CommScope representative for more information For ...

Отзывы: