8.1. 

DLX connector

8.1.1. 

Align the DLX-connectors as shown in Figure below. The protrusions on the drop cable connector should line up  

with the arrow on the FST-R adapter. Insert the drop cable connector into the FST-R adapter until it slides freely  into place 

and latches. Thread the drop cable connector coupling nut into the optical port and tighten coupling nut until fi nger tight.

8.1.2. 

Thread the optical port dust cap into the drop cable dust cap as shown below and then tighten both dust caps 

fi nger tight. This ensures that both dust caps will stay clean when not in use.

8.2. 

Full size hardened-connector

8.2.1. 

Align the Full size hardened-connectors as shown in Figure below. The pointer on the drop cable connector should  

line up with the notch on the FST-R adapter. Insert the drop cable connector into the optical port and tighten    

coupling nut until fi nger tight.

8.2.2. 

Thread the optical port dust cap into the drop cable dust cap as shown below and then tighten both dust caps 

fi nger tight. This ensures that both dust caps will stay clean when not in use.

COUPLING

NUT

NOTE: ORIENT CONNECTOR

SO ARROW IS ALIGNED

WITH PROTRUSIONS.

ARROW

PROTRUSIONS

OPTICAL PORT

DUST CAP

DROP CABLE

DUST CAP

ORIENT CONNECTOR

SO ARROW IS ALIGNED

WITH NOTCH

COUPLING

NUT

DROP CABLE

DUST CAP

OPTICAL PORT

DUST CAP

Содержание FST-R

Страница 1: ...al product information The FST R is a compact sealed terminal with hardened connectivity for reliable plug n play distribution to customer premises Featuring pre connectorized hardened full size or DLX adapter drops and a round loose tube feeder cable dia5 5mm to splice CommScope s FST R enables FTTH deployment in brown field and green field applications Primarily designed for hand hole applicatio...

Страница 2: ...alled in a site satisfying the following conditions 3 1 Avoid locations where temperature is too high or low FST R normally operates in an environment with the following conditions Operating temperature 20ºC 65ºC 3 2 Keep the product surroundings clean and dust free both during and after installation 4 Required Tools Standard tools to mount the FST R and cable preparation tools for splicing fibers...

Страница 3: ...t Dimension mm 6 2 Installing FST R in Hand Hole Pit wall pole 6 2 1 FST R can be fixed to the side of a hand hole pit wall using self tapping screw not included in kit 6 2 2 Ensure FST R is located in the pit with feeder situated below the customer ports to allow easy installer access ...

Страница 4: ...eeder cable to FST R Remove the cable jacket using the correct tools and RIP cord in the cable and handle the cable per standard local practice in the previous network element ex enclosure terminal or hub Cable OD 5 5 mm Loose tube OD 2 5 mm 8 Installing Drop cable Ensure you remove the dust caps Use the 216B key tool accessory to unscrew the dust cap from the optical port inspect and clean them i...

Страница 5: ... that both dust caps will stay clean when not in use 8 2 Full size hardened connector 8 2 1 Align the Full size hardened connectors as shown in Figure below The pointer on the drop cable connector should line up with the notch on the FST R adapter Insert the drop cable connector into the optical port and tighten coupling nut until finger tight 8 2 2 Thread the optical port dust cap into the drop c...

Страница 6: ...aning Note The drop cable connector uses angled SC type connectors Make sure the connector end face is point ing in the correct direction before starting the cleaning motion 9 1 1 5 With light pressure slide the connector end face once across the tape in the direction shown using a smooth linear motion Do not press too hard and do not repeat the cleaning motion with the same tape 9 1 1 6 Release t...

Страница 7: ...nnector end face once across the tape in the direction shown using a smooth linear motion Do not press too hard and do not repeat the cleaning motion with the same tape 9 2 1 6 Release the lever on the underside of the cassette to close the tape shutter 9 2 1 7 Repeat Step 9 2 1 3 through Step 9 2 1 6 until the connector has been cleaned three times 9 2 2 Full size hardened adapter cleaning 9 2 2 ...

Страница 8: ... a number of CommScope s facilities across the globe certified in accordance with international standards including ISO 9001 TL 9000 and ISO 14001 Further information regarding CommScope s commitment can be found at www commscope com About Us Corporate Responsibility and Sustainability 11 Contact information Visit our website or contact your local CommScope representative for more information For ...

Отзывы: