background image

5

5.6  

Splice the incoming fibers with 900µm pigtails and store the 

overlength in the tray

5.10  Installed box

5.7  

Slide the cover into the lateral guide slots in the base and push 

the cover downwards.

5.8  

To open the box with the cover in place, use a tool such as a 

screwdriver. Insert the screwdriver in the recess of the cover and push 
the grooved area of the lid.

Содержание FOWB

Страница 1: ...additional metal base plate can be used to secure bigger cables Ø 7 14 mm outside of the box The box provides cable entrances Ø 7mm on the top and bottom side of the box An additional cover is provided to protect the connectors from accidental disconnection A fold away splice cassette inside can support a maximum of 24 crimp splices 24 heat shrinkable splices or 12 mechanical splices 2 Kit content...

Страница 2: ... Wall mounting 2 3 2 To release the cassette push the hook in the middle of the cassette to the right side and push the splice cassette upwards The cassette will lock in place at an angle of approximately 90 degrees 4 1 The box can be mounted on to a wall 3x mounting holes or on to the supplied wall mounting plate with an additional strain relief for cables 4 2 Place the base plate at the required...

Страница 3: ...box downwards until the snap hook of the box engages with the hole in the base plate A Incoming cable with a diameter Ø 7 14 mm 4 4 To release the box push the snap hook as shown 100 mm 4 6 Adjust the cable with the base plate and mark the cable jacket 5mm below the edge of the base plate Strip the cable jacket Then strip the inner tube at the length of 100mm from the end of the cable jacket 4 7 S...

Страница 4: ...id micro bends in the fiber 5 1 Remove all the plugs from the adapters 5 4 Remove the second splice holder before inserting the splices B Incoming cable with a diameter Ø 3 6 5 mm Tie Inner tube 4 8 Top cable entrance Secure the cable with tie wrap at the marked position The tie wrap should only be slightly tightened to avoid micro bends in the fiber Tie Inner tube 5 Fiber management 5 2 Plug in a...

Страница 5: ... the tray 5 10 Installed box 5 7 Slide the cover into the lateral guide slots in the base and push the cover downwards 5 8 To open the box with the cover in place use a tool such as a screwdriver Insert the screwdriver in the recess of the cover and push the grooved area of the lid ...

Страница 6: ...y specifications or warranties relating to CommScope products or services This product is covered by one or more U S patents or their foreign equivalents For patents see www commscope com ProductPatent ProductPatent aspx To find out more about CommScope products visit us on the web at www commscope com For technical assistance customer service or to report any missing damaged parts visit us at htt...