6
Cable bonding and grounding
6.1
For cable with shielding, remove a section of the outer sheath 180⁰ around the cable by
1.0”
in length measured
from the end of the outer sheath in order to expose cable shielding. See photo 82.
Photo 82
6.2
For grounding, press ground bar into slot in closure.
6.3
If using Inline configuration, install inline ground bar and secure with bolt. See photo 83.
Photo 83
6.4
External ground connection is to be placed in designated location.
6.5
The ground wire is to be secured using the same bolt that is used to secure the cable retention assembly or
secured with bolt. See photo 84.
Caution: Do not use braided or stranded ground wire when installing a ground through a port on the Mini-OTE
300 closure. A solid ground wire is required to prevent a leak path and make a proper seal.
Photo 84