8
Installation (continued)
3A
Making electrical connections
(+) Line
Black
White
Lighting
Fixture
Green
(-) Common
Ground
3/8 in.
Non-Dimming Wiring Diagram
(+) Line
Black
White
Lighting
Fixture
Green
(-) Common
Purple
(+)DIM V+
Gray
(-)DIM V-
Ground
0−10V Dimming Wiring Diagram
(APPLICABLE FOR ROUND PIPE / TENON
MOUNTING ONLY)
□
If necessary, strip 3/8 in. of insulation from the junction box
or fixture (A) wires.
ON/OFF Wiring (Non Dimming) Method:
□
Connect the fixture black wire to the supply black wire ((+)
line), and fixture white wire to the supply white wire ((-)
common) by twisting the exposed wires together and using
the wire nuts (BB). Ensure there are no loose wires.
□
Connect the supply ground wire to the green fixture ground
wire by twisting the exposed wires together and using the
wire nuts (BB).
0-10V Dimmable Wiring Method:
□
Connect the fixture black wire to the supply black wire ((+)
line), and fixture white wire to the supply white wire ((-)
common) by twisting the exposed wires together and using
the wire nuts (BB). Ensure there are no loose wires.
□
Connect the supply ground wire to the green fixture ground
wire by twisting the exposed wires together and using the
wire nuts (BB).
□
Connect the purple wire to the (V+) DIM wire and the
gray wire with (V-) DIM wire by twisting the exposed wire
together and using the wire nuts (BB).
NOTE:
Hold stripped ends near each other and align any
frayed strands (do not twist wires).
Push the wires into wire nut (BB) and use your fingers to
twist the wire nut clockwise until tight. Check for tightness by
pulling wires.