Installation (continued)

4B

Mounting the extension arm

AA

HH

GG

GG

GG

DD

IMPORTANT:

 Pay attention to threading the wire through the 

center hole in the bolster plate (HH), the pole, the round pole 
adapter plate (DD), and the extension arm (AA).

For Square Pole Only:

 

Align the extension arm (AA) holes with the holes drilled on 
the pole.

 

Attach the extension arm (AA) by inserting the two hex 
head bolts (GG) through the extension (AA), the pole and 
the bolster plate (HH), which is inside the pole (fig 1).

 

Tighten the two bolts (GG) to 140 in-lbs (16 Nm). 

For Round Pole Only:

 

Use the round pole adapter plate (DD) between the pole 
and the extension arm (AA).

 

Insert the two hex head bolts (GG) through the extension 
arm (AA), round pole adapter plate (DD), the pole and the 
bolster plate (HH), which is placed inside the pole (fig 2).

 

Tighten the two bolts (GG) to 140 in-lbs (16 Nm). 

For Direct to Wall:

 

Align the extension arm (AA) holes with the holes pre-
drilled in the wall.

 

Use proper bolts or wall anchors for the type of wall, and 
tighten to sufficient torque setting.

 

Consult with a qualified electrician to determine the best 
mounting method and bolts for wall mount.

 

Place electrical wires through the center hole in the 
extension arm (AA).

CAUTION:

 Do not use the bolts included in the hardware 

kit for direct to wall mounting (they are intended for pole 
mounting). Use bolts or screws and anchors suitable for the 
wall’s surface material. Consult with a qualified electrician to 
help determine the best mounting method and bolts for wall 
mount.

NOTE:

 The light fixture has precision Type IV forward throw 

optics so when using the extension arm mount keep the 
fixture in the 0° position.

Содержание 1003 943 420

Страница 1: ...your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Commercial Electric USE AND CARE GUIDE NOVA COMMERCIAL LED AREA LIGHT Quest...

Страница 2: ...and 2 this device must accept any interference received including any interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A...

Страница 3: ...Installation PLANNING INSTALLATION Before installing the light fixture ensure that all parts are present Compare parts with the Hardware Included and Package Contents sections If any part is missing o...

Страница 4: ...Flat washers 3 DD Adapter plate for round pole 1 EE Photocell black cover label 1 FF Allen key 3 GG Hex head lag bolts 2 HH Bolster plate 1 PACKAGE CONTENTS D B C A B E Part Description Quantity A Li...

Страница 5: ...t to a wall using the extension arm supplied separately in the package To ensure proper dusk to dawn operation ensure the photocell is oriented at the top for a wall mount installation in an area that...

Страница 6: ...sticker EE on the photocell window Place the photocell E onto the receptacle B on top of the fixture Twist the photocell E in the direction of the arrow indicated on the photocell until it locks into...

Страница 7: ...4A to complete the wiring and use wire nuts BB on the connections Fig 1 Place the knuckle arm on the pole and use the allen key FF to tighten the two bolts and fix the fixture on the pole Fig 2 SLIPFI...

Страница 8: ...ground wire to the green fixture ground wire by twisting the exposed wires together and using the wire nuts BB 0 10V Dimmable Wiring Method Connect the fixture black wire to the supply black wire line...

Страница 9: ...ued 4A Adjusting the fixture head orientation C FF Fig 1 Fig 2 Fig 3 Remove the plug from the side of the knuckle arm C Fig 1 Use the allen key FF to loosen the screw and adjust the angle to desired o...

Страница 10: ...loosen the screw to remove the bottom handle Fig 1 2 Remove the four screws from the slipfitter upper handle by using the larger allen key FF to remove the knuckle mounting arm C completely Fig 3 Thr...

Страница 11: ...es into the pole or surface as this figure shows Extension Arm Usages Use the extension arm to mount the fixture direct to a surface like square pole round pole or a wall IMPORTANT Please refer to the...

Страница 12: ...the pole and the bolster plate HH which is placed inside the pole fig 2 Tighten the two bolts GG to 140 in lbs 16 Nm For Direct to Wall Align the extension arm AA holes with the holes pre drilled in t...

Страница 13: ...nsure there are no loose wires Connect the supply ground wire to the green fixture ground wire by twisting the exposed wires together and using the wire nuts BB 0 10V Dimmable Wiring Method Connect th...

Страница 14: ...t all times to enable dusk to dawn functionality to operate automatically IMPORTANT To test if the light fixture A and photocell E works properly run power to the fixture and cover the photocell to tu...

Страница 15: ...eflected light Relocate the light fixture to a location where there is no reflected light OR place the optional photocell cover over the photocell light sensor and use the wall switch to turn the ligh...

Страница 16: ...Questions problems missing parts Before returning to the store call Commercial Electric Customer Service 9 a m 5 p m EST Monday Friday 1 844 548 3776 HOMEDEPOT COM Retain this manual for future use...

Отзывы: