2) Wiring

Please pay attention to the polarity of the wires. Units will not work properly when mis-wired 

- When using a UTP(CAT.5) cable, be sure to check the connection of the color of the wires

as shown in the picture above.

- Within 20m between Build Distributor and Multi Entry Panel, the power is supplied from the 

Building Distributor.

- Greater than 20m to less than 100m between Build distributor and Multi entry panel, 

the Multi Entry Panel requires separate power source
(In this case, there is no power line connection between the Build Distributor and 

the Multi Entry Panel) 

- The allotted ID of the Multi Entry Unit should match with the assigned number of 

the connection terminal of Building Distributor (CCU-BS) 

- When wiring, please use a tool like a screwdriver.

Multi Entry Panel

Build distributor

ID : 1

Terminal 1

ID : 2

Terminal 2

ID : 3

Terminal 3

ID : 4

Terminal 4

1

Warnings and caution

Features

Part names and Functions

Calling In-house unite by resident Number

Calling In-house unite by the listed resident names

Calling / talking duration

Open the entrance with PIN Number

Setting the ID for Multi-Entry Panel

Setting In-House unit aas master and Sub Units

Changing the  password

Connectable Products

Resident registration program

Wiring and System Diagram

Specification

2

Table of Contents

4

6

7

7

10

8

9

8

7

11

11

15

17

Содержание DRC-MSB

Страница 1: ...In Korea 2007 12 Thank you for purchasing our COMMAX product Please carefully read this User s Guide in particular precautions for safety before using the product and follow the instructions to use y...

Страница 2: ...5Lux 3 Lux DC24 DC28V 5A powered by building distributor Wiring Power voltage Screen dimension Standby 60mA Maximum operation 450mA Max WhenpowersourceissuppliedfromBuildingDistributor Lessthan20m Wh...

Страница 3: ...ti Entry Panel The allotted ID of the Multi Entry Unit should match with the assigned number of the connection terminal of Building Distributor CCU BS When wiring please use a tool like a screwdriver...

Страница 4: ...yusingadryclothto preventanybreakdownorelectric shock Do not install the product in a humid place It may cause an electric shock or a fire Do not forcibly pull out the cord from the socket If the cord...

Страница 5: ...1 txt shown above Name list shown below will not take priority to be saved over the existing data AptNo1 txt If the socket holes are larger than normal do not put the plug It may cause an electric sho...

Страница 6: ...allation all wiring can be used with UTP cable CAT 5 2 Connect up to 4 Multi Entry Panels per building 3 Connect up to 4 residences per single Floor distributor CCU FS 4 Connect Multi Entry Panels wit...

Страница 7: ...6 Select the port connecting with the computer in Select Port 7 Select Add to enter a resident number and name 5 8 Screen display duration lasts for 30 seconds after receiving a call 9 Talking duratio...

Страница 8: ...of download cable to the serial port of the PC and Connect other side 3P connector to RS232 Port of Building Distributor 11 1 Building Distributor CCU BS one Building Distributor is connected to up t...

Страница 9: ...e unit s case 2 While pressing SW2 turn on the Building Distributor and the password will initialize to 4321 and the Lamp will blink for 3 seconds 10 Changing the password 7 1 Press the buttons accord...

Страница 10: ...ntry Panel when you press the Door release button on an in house unit 5 Then register the ID of the shown residence and press button to hear a sound of completion 6 The registration is complete when y...

Отзывы: