![COMITRONIC-BTI SM1 Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/comitronic-bti/sm1-series/sm1-series_instruction-manual_2642139006.webp)
SM1
SM2
OX
PL-AC
OX
Supply voltage
21.6 VDC to 26.4 VDC
Power supply without magnet action
40 mA to 24 VDC
Power supply with magnet action
Type E
Type R
670 mA
150 mA
0.21 A
0.075 A
1.35 A
0.3 A
Connection
8 x 0.25 mm²
Rmin > 50
M12 male 8 pin
baseplate
8 x 0.25 mm²
Rmin> 50
LED lighting
Yes
No
Specifications of contacts
Safety: 2 x 40 V/300 mA, Diagnostics: 40 V/300 mA
Operating temperature
-25°C to +50°C (-13° to +122° F)
Detection distances
Sn (typical distance)
Sao (ensured activation distance)
Sar (ensured rupture distance)
Offset
5 mm
4 mm
8 mm
Centering and parallelism to be performed
Holding force
R
E
~ 500 N
~ 400 N
~ 500 N
~ 300 N
~ 936 N
~ 820 N
Water tightness
IP 69K box
IP 67 connector
IP 54
IP 69K box
IP 67 connector
Box/housing material
Cable or connector
Stainless steel
316L
PUR polyether
PA6
Cu/Ni baseplate
Stainless steel
316L
PUR polyether
Weight with packaging
1110 g
700 g
2000 g
Screw mounting
2 x M4
2 x M4
2 x M6
7. Main Features
6
8. Assembly Instructions
8.1 SM1-PL and SM1-OX
a) Drill the holes of the mounting bracket at
F
= 4.5 mm, with a center distance of 72 mm.
b) Use the stainless steel washers supplied with the product in order to preserve the box's casing
c) With the door closed, the distance between the polar plate and the suction cup should ideally be 0.
The polar plate is flexible which makes it possible to compensate for function
d) The bending radius of the cable must be greater than 50 mm.
e) Use tamper-proof screws
8.2 SM2
a) Drill the holes of the mounting bracket at
F
= 6.5 mm, with a center distance of 163 mm.
b) c) d) e) Same as in §7.1
f) The transmitter can be equipped with the EPB handle. The advantage is to ensure a pulling force in
the axis of the suction cups and thus obtain the maximum force by avoiding the leverage effect.
SM1 AND SM2 SERIES
Hold and interlock