COMITRONIC-BTI SM1 Series Скачать руководство пользователя страница 6

SM1

SM2

OX

PL-AC

OX

Supply voltage

21.6 VDC to 26.4 VDC

Power supply without magnet action

40 mA to 24 VDC

Power supply with magnet action

Type E

Type R

670 mA

150 mA

0.21 A

0.075 A

1.35 A

0.3 A

Connection

8 x 0.25 mm²

Rmin > 50

M12 male 8 pin 

baseplate

8 x 0.25 mm² 

Rmin> 50

LED lighting

Yes

No

Specifications of contacts

Safety: 2 x 40 V/300 mA, Diagnostics: 40 V/300 mA

Operating temperature

-25°C to +50°C (-13° to +122° F)

Detection distances

Sn (typical distance)

Sao (ensured activation distance) 

Sar (ensured rupture distance)

Offset

5 mm

4 mm

8 mm

Centering and parallelism to be performed

Holding force

R

E

~ 500 N

~ 400 N

~ 500 N

~ 300 N

~ 936 N

~ 820 N

Water tightness

IP 69K box

IP 67 connector

IP 54

IP 69K box

IP 67 connector

Box/housing material

Cable or connector

Stainless steel 

316L

PUR polyether

PA6

Cu/Ni baseplate

Stainless steel 

316L

PUR polyether

Weight with packaging

1110 g

700 g

2000 g

Screw mounting

2 x M4

2 x M4

2 x M6

7. Main Features

6

8. Assembly Instructions

8.1 SM1-PL and SM1-OX

a) Drill the holes of the mounting bracket at 

F

= 4.5 mm, with a center distance of 72 mm.

b) Use the stainless steel washers supplied with the product in order to preserve the box's casing

c) With the door closed, the distance between the polar plate and the suction cup should ideally be 0. 

The polar plate is flexible which makes it possible to compensate for function

d) The bending radius of the cable must be greater than 50 mm.

e) Use tamper-proof screws

8.2 SM2

a) Drill the holes of the mounting bracket at 

F

= 6.5 mm, with a center distance of 163 mm.

b) c) d) e) Same as in §7.1

f) The transmitter can be equipped with the EPB handle. The advantage is to ensure a pulling force in 

the axis of the suction cups and thus obtain the maximum force by avoiding the leverage effect.

SM1 AND SM2 SERIES

Hold and interlock

Содержание SM1 Series

Страница 1: ...RS OF DANGEROUS MACHINES new generation Made in France SIL 2 CAT 3 Pld contacts 2A 48V 2 million operations at full load 3 year guarantee INNOVATION IS OUR DRIVING FORCE ADAPTABILITY IS OUR CULTURE CO...

Страница 2: ..._______________________________ 6 Summary of applications_________________________________________________ 7 Main Features__________________________________________________________ 8 Assembly Instruct...

Страница 3: ...sion R sticking with power on fire EOP version sticking with power off and compatible with ISO 14119 machine ROP version sticking with power on and compatible with ISO 14119 machine Stainless steel 31...

Страница 4: ...f 4 Door closed and locked Open request closed door Door open EOP 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact open 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact closed 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24...

Страница 5: ...cations by model Door closed and locked Open request closed door Door open R 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact open 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact closed 1 5 4 6 3 24 VDC 2 7 LA...

Страница 6: ...i baseplate Stainless steel 316L PUR polyether Weight with packaging 1110 g 700 g 2000 g Screw mounting 2 x M4 2 x M4 2 x M6 7 Main Features 6 8 Assembly Instructions 8 1 SM1 PL and SM1 OX a Drill the...

Страница 7: ...ld and interlock 144 117 2 6 39 S c r e w c o v e r 11 EPB handle dimensions optional item M8 for handle attachment center distance 117 mm PL OX 82 5 72 R 50 31 5 6 1 5 20 5 3 2 F4 3 Antibacterial han...

Страница 8: ...26XXL monitoring on off management B22 CV 1OL RGO D3T10 BU MKT opening command SPEEDTRONIC zero speed control FKT 5 m 10 m or 15 m connection FKT cord Brown Blue White Pink Yellow Gray Green Red 1 5 4...

Страница 9: ...t the LED turns off Check that contacts 1 5 and 4 6 are open Check that contact 3 is closed supply voltage Approach the transmitter at 4 mm SM1 Observe that the LED lights up Check that contacts 1 5 a...

Страница 10: ...2017 Authorized signature Christophe Pays Technical Manager EU DECLARATION OF CONFORMITY This document is the conformity declaration concerning safety switches and relays conforming to the Machine Di...

Страница 11: ...14 Rue Pierre Paul de Riquet 33610 Can jan 33 5 64 10 04 52 www comitronic bti com COMITRONIC BTI SMEN_250618_v0 0...

Отзывы: