COMITRONIC-BTI SM1 Series Скачать руководство пользователя страница 2

SM1 AND SM2 SERIES

Hold and interlock

CONTENTS

SM1 and SM2___________________________________________________________________

  

1. Benefits_______________________________________________________________

 

2. Precautions for use _____________________________________________________

 

3. Principle_______________________________________________________________

 

3.1. Sticking with power off (machine) or sticking with power on (fire) _____________

 

3.2. Interlocking __________________________________________________________

 

4. Operation of OP versions________________________________________________

 

4.1. EOP Version : interlocking with power off_________________________________

 

4.2. ROP Version : interlocking with power on_________________________________

 

5. Operation of versions E and R____________________________________________

 

5.1. Version E : holding force with power off___________________________________

 

5.2. Version R : holding force with power on___________________________________

 

6. Summary of applications_________________________________________________

 

7. Main Features__________________________________________________________

 

8. Assembly Instructions___________________________________________________

 

8.1. SM1-PL and SM1-OX __________________________________________________

 

8.2. SM2_________________________________________________________________

 

9. SM1 Model dimensions__________________________________________________

 

10. SM2 Model dimensions_________________________________________________

 

11. EPB handle dimensions_________________________________________________

 

12. Complete solution of interlocking machine with inertia_______________________

 

13. Recommendations______________________________________________________

 

14. Periodic inspection ____________________________________________________

 

15. Item code_____________________________________________________________

DECLARATION OF CONFORMITY_________________________________________________

THE DEVICES OF MONITORING AWAX SERIES (extract)________________________________

2

3

3

3

4

4

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

8

9

9

10

11

12

Содержание SM1 Series

Страница 1: ...RS OF DANGEROUS MACHINES new generation Made in France SIL 2 CAT 3 Pld contacts 2A 48V 2 million operations at full load 3 year guarantee INNOVATION IS OUR DRIVING FORCE ADAPTABILITY IS OUR CULTURE CO...

Страница 2: ..._______________________________ 6 Summary of applications_________________________________________________ 7 Main Features__________________________________________________________ 8 Assembly Instruct...

Страница 3: ...sion R sticking with power on fire EOP version sticking with power off and compatible with ISO 14119 machine ROP version sticking with power on and compatible with ISO 14119 machine Stainless steel 31...

Страница 4: ...f 4 Door closed and locked Open request closed door Door open EOP 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact open 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact closed 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24...

Страница 5: ...cations by model Door closed and locked Open request closed door Door open R 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact open 1 5 4 6 3 24 VDC 2 7 LATCH 8 0V 24V contact closed 1 5 4 6 3 24 VDC 2 7 LA...

Страница 6: ...i baseplate Stainless steel 316L PUR polyether Weight with packaging 1110 g 700 g 2000 g Screw mounting 2 x M4 2 x M4 2 x M6 7 Main Features 6 8 Assembly Instructions 8 1 SM1 PL and SM1 OX a Drill the...

Страница 7: ...ld and interlock 144 117 2 6 39 S c r e w c o v e r 11 EPB handle dimensions optional item M8 for handle attachment center distance 117 mm PL OX 82 5 72 R 50 31 5 6 1 5 20 5 3 2 F4 3 Antibacterial han...

Страница 8: ...26XXL monitoring on off management B22 CV 1OL RGO D3T10 BU MKT opening command SPEEDTRONIC zero speed control FKT 5 m 10 m or 15 m connection FKT cord Brown Blue White Pink Yellow Gray Green Red 1 5 4...

Страница 9: ...t the LED turns off Check that contacts 1 5 and 4 6 are open Check that contact 3 is closed supply voltage Approach the transmitter at 4 mm SM1 Observe that the LED lights up Check that contacts 1 5 a...

Страница 10: ...2017 Authorized signature Christophe Pays Technical Manager EU DECLARATION OF CONFORMITY This document is the conformity declaration concerning safety switches and relays conforming to the Machine Di...

Страница 11: ...14 Rue Pierre Paul de Riquet 33610 Can jan 33 5 64 10 04 52 www comitronic bti com COMITRONIC BTI SMEN_250618_v0 0...