background image

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT.  MULTIPLE POWER SOURCES MAY BE PRESENT.  FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

27

WIRING DIAGRAMS

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

TO +VDC

TO

MICRO

TO

R

GND (4)

+ VDC (1)

RX (2)

TX (3)

CIRCULATOR

INDOOR

AIR

BLWR

RD

GY

BL

BK

PROPERLY POLARIZED

HUMIDIFIER

GND

PROTECTION DEVICE

HEAT OFF 

DELAY

BURNER COMPARTMENT

24 V 
3 A

BL

POWER SUPPLY WITH

LINE

12

TO

C

2

BK

RD

UNUSED

DISCONNECT POWER

4

IGNITER

FLAME SENSOR

INTEGRATED CONTROL MODULE

POWER BEFORE

YL

TERMINAL

HI

OR ORANGE

MVH (14)

CO

NN

E

C

T

O

R

PM

ECM MTR 

HARNESS

NO

24 VAC

HI VOLTAGE FIELD

115kBTU MODELS

AUTO RESET PRIMARY 

LIMIT CONTROL

BEFORE SERVICING.

RD

PS1 (2)

3

YL YELLOW

CIRCULATOR

BK

BR BROWN

4

BK

 OVERCURRENT

24V HUM.

0140F00660        REV. A

IGNITER

115 VAC/ 1

BLOWER COMPARTMENT

24

BK

PM

1

WH WHITE

FUSE

15

INDUCED

DRAFT 

BLOWER

EAC

C

3

BL BLUE

6

115 VAC

INDUCTOR COIL

WH

GND

5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST 
   RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE 
   IN STANDBY (NO THERMOSTAT INPUTS)

Ø /60 HZ POWER SUPPLY WITH

ADJUST

TO 115VAC/ 1

BK BLACK

DEHUM

5

HEAT

LINE

GND

24V HUM.

2

BK

HOT

SURFACE

IGNITER

MVC (8)

2

NEUTRAL

RD

WH

DOOR

LOW FIRE PRESS. 
SWITCH

4

3

2

WH

VAC

GND

LOW VOLTAGE  (24V)

2 CIRCUIT
CONNECTOR

HUM

DEHUM

2

HI VOLTAGE (115V)

OVERCURRENT

PSO (7)

WH

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE 
   USED WHEN SERVICING.

ONLY

C

AIR CLEANER

TWO STAGE

GAS VALVE

(HONEY WELL)

DISCONNECT

HIGH FIRE 
PRESS. SWTICH

INDOOR

HUMIDIFIER

Ø /60 HZ

PK PINK

N

9

MANUAL RESET ROLLOUT 
LIMIT CONTROLS

IND LO

14

40 VA

AUTO RESET AUXILIARY LIMIT 

CONTROLS

HU

M

YL

JUNCTION

BLWR

PU  PURPLE

1

CIRCULATOR 
BLOWER

R

1

GND

JUNCTION BOX

SWITCH (TEMP.)

NEUTRAL

115kBTU MODELS

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
 DOOR OPEN)

C

LINE

BK

YL

NEUTRAL

4

NEUTRAL

POLARIZED AND

11

C

FS

2

PLUG CONNECTION

DISCONNECT

PU

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE 
   FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH  
   WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT 
   LEAST 105 C. USE COPPER CONDUCTORS ONLY.

IN
T

E

G

R

A

T

E

D

 

CO

N

T

RO

L

 

MO

D

U

L

E

RD

INTEGRATED CONTROL

PROT. DEVICE

8

HIGH FIRE 

PRESSURE 

SWITCH

WH

ONLY

24 V THERMOSTAT CONNECTIONS

W1

       INTERNAL TO

70kBTU,90kBTU,

NO

EQUIPMENT GND

MVL (13)

O

SERVICING. WIRING

2ND STG DLY

WH

RD

YL

ID BLOWER TWO-STAGE PRESSURE 

SWITCH ASSEMBLY

BL

5

GND (5)

BK

IND HI

IGN

PK

HLO (10)

70kBTU,90kBTU,

NOTES:

PU

L

AIR

WH

MANUAL RESET ROLLOUT LIMIT 

CONTROLS 

Y1

GY GRAY

ELECTRONIC

RD RED

Y2

RD

NEUTRAL

1

HLI (1)

WH

SWITCH

AUTO RESET PRIMARY 

LIMIT CONTROL

NO

TRANSFORMER

MUST BE PROPERLY

13

BL

3

OVERCURRENT PROTECTION DEVICE

T-STAT

5

BR

BK

2

GROUNDED.

LOW VOLTAGE  FIELD

W2

DELAY

WARNING:

7

FIELD GND

FIELD SPLICE

SWITCH (PRESS.)

W2

WH

115

NEUTRAL

BLWR

3

GND

FS

1

AND GROUNDED.

4

GAS 
VALVE

PU

INDUCTOR COIL

TH (4)

C

HI

2

4

V

 H

U

M

.

TO UNIT MUST BE

VAC

G

YL

C

TR (11)

YL

GR

GN GREEN

HOT SURFACE

FLAME
SENSOR

PS2 (12)

LOW FIRE 

PRESSURE 

SWITCH

1

COLOR CODES:

L

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO 
   N.E.C. AND LOCAL CODES.

DIAGNOSTIC 

LED'S

RD

3

10

WIRING TO  UNIT

OR

NO

NEUTRAL

N

SEE 
NOTE 5

BR

COOL

40 VA
TRANSFORMER

ID

TO 
MICRO

WARNING:DISCONNECT

PU

AUTO RESET
AUXILIARY
LIMIT CONTROL

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

FUSE 3 A

2

2

4

V

 T

H

E

R

M

O

S

T

A

T

 C

O

N

N

E

C

T

IO

N

S

5 C

IRC
UI
T

 C
O

NN

E

C

T

O

R

E

A

C

BK

4

 CIR

CUI

T

 M
O

T

O

3

T

W
O

-S

T

A

G

E

1

DE

H

U

M

YL

YL

WH

R

IN

T

E

G

R

A

T

E

D

 C

O

N

T

R

O

L

 M

O

D

U

L

E

GN

W1

JUNC

T

IO

N

 B
O

X

WH

OR

BL

CHA

S

S

IS

 G
R

O

UND

BK

IN

T

E

G

R

A

T

E

D

 C

O

N

T

R

O

L

 M

O

D

U

L

E

G

Y2

O

2

1

YL

BR

WH

DI
P

 S
W
IT

CH

E

S

Y1

WH

RD

1

C

*MVC8***AB, *DVC8***AA Models

Содержание ADVC8

Страница 1: ...to improper service procedures performed by an unqualified person ADVC8 AMVC8 GMVC8 80 Gas Furnace Units Refer to Service Manual RS6200004 for installation operation and troubleshooting information Al...

Страница 2: ...ge personal injury or death Goodman will not be responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you ass...

Страница 3: ...uld questions arise contact your local EPA office WARNING WARNING Do not connect or use any device that is not design certified by Goodman for use with this unit Serious property damage personal injur...

Страница 4: ...ower door is not in place Keep the blower access doors in place except for inspection and maintenance These furnaces are also equipped with a self diagnosing elec tronic control module In the event a...

Страница 5: ...ONVERSIONKITREQUIR ED Tableddataisbaseduponthefurnaceinputbeingreducedforaltitudesabovesealevel U S 4 per1 000feet Canada10 deratefor2 000 4 000feet ELEVA TIONA BOVESEA LEVEL FEET INPUTPERBURN ER 22 5...

Страница 6: ...Door Interlock Switch Transformer Circulator Blower 1 2 3 4 5 6 7 8 9 Inductor 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Draft Blower 5 Gas Line Entrance 6 Gas Valve...

Страница 7: ...r Blower Inductor Pressure Switch 2 Gas Line Entrance Alternate Tubular Heat Exchanger 1 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Draft Blower 5 Gas Line Entrance 6...

Страница 8: ...8_____X Alt Gas Inlet High Voltage Inlet Low Voltage Alt Gas Inlet Alt High Voltage Alt LowVoltage MODELS A B AMVC80704BX GMVC80704BX 17 1 2 16 AMVC80905CX AMVC81155CX GMVC80905CX GMVC81155CX 21 19 1...

Страница 9: ...S 33 3 8 A B 28 High Voltage Electrical Low Voltage Electrical Gas Inlet MODEL A B NON COMBUSTIBLE FLOOR BASE ADVC80703BX 17 1 2 16 SBT17 ADVC80905CX ADVC81155CX 21 19 1 2 SBT21 All dimensions are in...

Страница 10: ...0 3 B X 1 A D V C 8 0 9 0 5 C X 1 A D V C 8 1 1 5 5 C X 1 A U X I L I A R Y L I M I T S W I T C H E S MODEL TRIP POINT ID BLOWER PRESSURE SWITCH LOW STAGE TRIP POINT ID BLOWER PRESSURE SWITCH HIGH STA...

Страница 11: ...CAUF equivalent All CHPF coils in B C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor un...

Страница 12: ...mine filter area requirement NOTE Filters can also be installed elsewhere in the duct system such as a central return FURNACE INPUT FILTER SIZE TYPE 45M 160 in2 permanent 70M 241 in2 permanent 90M 320...

Страница 13: ...owing downflow top return filter sizes depending on cabinet size Refer to Minimum Filter Area tables to determine filter area requirement NOTE Filters can also be installed elsewhere in the duct syste...

Страница 14: ...ted External Static w c 10 50 10 50 10 50 Temperature Rise F 20 50 20 50 25 55 High Stage Pressure Switch Trip Point w c 0 65 0 60 0 60 Low Stage Pressure Switch Trip Point w c 0 30 0 30 0 30 Blower W...

Страница 15: ...0 50 25 55 High S tage P res s ure S witc h Trip P oint w c 0 65 0 60 0 60 Low S tage P res s ure S witc h Trip P oint w c 0 30 0 30 0 30 B lower W heel D x W 10 x 8 10 x 10 10 x 10 B lower Hors epowe...

Страница 16: ...80 Rated External Static w c 10 50 10 50 10 50 Temperature Rise F 30 60 35 65 35 65 High Stage Pressure Switch Trip Point w c 0 55 0 55 0 55 Low Stage Pressure Switch Trip Point w c 0 30 0 30 0 30 Bl...

Страница 17: ...g Speed Tap Adjust Tap Low Stage CFM High Stage CFM Rise F Minus 790 1125 46 Minus 945 1350 49 Normal 875 1250 41 Normal 1050 1500 44 Plus 960 1375 38 Plus 1155 1650 40 Minus 850 1215 43 Minus 1010 14...

Страница 18: ...Minus 540 Minus 720 Minus 720 Normal 600 Normal 800 Normal 800 Plus 660 Plus 880 Plus 880 Minus 720 Minus 990 Minus 990 Normal 800 Normal 1100 Normal 1100 Plus 880 Plus 1210 Plus 1210 Minus 990 Minus...

Страница 19: ...w c and 0 8 w c is tabulated for cooling purposes only 6 Motor CFM maximum ADVC8 Continuous Fan Speed Chart AMVC8 GMVC8 Continuous Fan Speed Chart Model Furnace Maximum CFM Continuous Fan Speed 1 2 A...

Страница 20: ...e CFM Rise F Heating Speed Tap Adjust Tap Low Stage CFM High Stage CFM Rise F Minus 660 945 55 Minus 850 1215 55 Normal 735 1050 49 Normal 945 1350 49 Plus 810 1155 45 Plus 1040 1485 45 Minus 725 1035...

Страница 21: ...ng Speed Tap Adjust Tap CFM 1 Minus 540 Minus 720 Minus 765 Normal 600 Normal 800 Normal 850 Plus 660 Plus 880 Plus 935 Minus 720 Minus 990 Minus 1035 Normal 800 Normal 1100 Normal 1150 Plus 880 Plus...

Страница 22: ...ximum CFM capaibility is 1760 CFM the continuous fan speed will be 0 30 X 1760 CFM 530 CFM Example If the furnace maximum CFM capaibility is 1760 CFM the continuous fan speed will be 0 30 X 1760 CFM 5...

Страница 23: ...FF ramping profiles These profiles may be used to enhance cooling performance and increase comfort level The ramping profiles are selected using DIP switches 5 and 6 Refer to the following figure for...

Страница 24: ...shown on rating plate 5 Do not operate above 0 5 w c ESP in heating mode Operating between 0 5 w c and 0 8 w c is tabulated for cooling purposes only 6 Motor CFM maximum 100 CFM OFF OFF Profile C ramp...

Страница 25: ...30 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU...

Страница 26: ...IFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING ONLY C AIR CLEANER HIGH FIRE PRESS SWTICH INDOOR HUMIDIFIER PK PINK WH 9 IND LO 14 Y2 40 VA 3 HUM YL JUNCTION BLWR PU PURPLE 1 CIRCULATOR BLOW ER R...

Страница 27: ...NTROLS HUM YL JUNCTION BLWR PU PURPLE 1 CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN C LINE BK YL NEUTRAL 4 NEUTRAL POLA...

Страница 28: ...0 AUTOMATIC IGNITION SYSTEM 24VAC 60Hz 0 8 A MAX 15 12 GND 13 9 G TX 2 O G 1 59 4715 REV F Y2 7 W1 3 W2 C IND LO 2 RX IND HI Y 1 Y1 O 1 G O DEHUM R R IND N HUM ST5 ST4 HUM C FS Y 2 1 DE HUM Y2 10 W 1...

Страница 29: ...ference only Not all wiring is as shown above Refer to the appropriate wiring diagram for the unit being serviced Wiring is subject to change Always refer to the wiring diagram on the unit for the mos...