www.fmiproducts.com
124978-01B
25
POSSIBLE CAUSE
1. Control knob not fully
pressed in
2. Control knob not pressed in
long enough
3. Safety interlock system has
been triggered
4. Equipment shutoff valve not
fully open
5. Thermocouple connection
loose at control valve
6. Pilot flame not touching
thermocouple, which al
-
lows thermocouple to cool,
causing pilot lame to go
out. This problem could be
caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
7. Thermocouple damaged
8. Control valve damaged
1. Burner oriice is clogged
2. Inlet gas pressure too low
1. Manifold pressure too low
2. Burner oriice is clogged
1. Burner oriice is clogged or
damaged
2. Burner damaged
3. Low inlet gas pressure
4. Gas regulator defective
1. Not enough air
2. Gas regulator defective
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds
3. Wait one minute for safety
interlock system to reset.
Repeat ignition operation
4. Fully open equipment shut
-
off valve
5. Hand tighten until snug,
then tighten 1/4 turn more
6. A) Contact local propane/
LP or natural gas com-
pany
B) Clean ODS/pilot (see
Cleaning and Maintenance
,
page 23) or replace ODS/
pilot assembly
7. Replace pilot assembly
8. Replace control valve
1. Clean burner (see
Cleaning
and Maintenance
, page 23)
or replace burner oriice
2. Contact local propane/LP
or natural gas company
1. Contact local propane/LP
or natural gas company
2. Clean burner (see
Cleaning
and Maintenance
, page 23)
or replace burner oriice
1. Clean burner (see
Cleaning
and Maintenance
, page 23)
or replace burner oriice
2. Replace burner pressure
3. Contact local propane/LP
or natural gas company
4. Replace gas regulator
1. Check burner for dirt and
debris. If found, clean
burner (see
Cleaning and
Maintenance
, page 23)
2. Replace gas regulator
OBSERVED PROBLEM
ODS/pilot lights but lame
goes out when control knob
is released
Burner does not light after
ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during
combustion
Yellow lame during burner
combustion
TRoUBlesHooTING
Continued