Comfortflame CGCFTNA Скачать руководство пользователя страница 13

www.fmiproducts.com

124978-01B

13

INsTAllATIoN

Continued

9.  Check all gas connections for leaks. See 

Checking Gas Connections,

 page 18.

10. Carefully  insert  fireplace  into  cabinet 

mantel (see Figure 13). Be careful not to 
scratch or damage hearth base or cabinet 
mantel. 

11. Place metal trim on shoulder screws locat

-

ed on the side and top of the ireplace (see 

Assembling Perimeter Trim

). Firmly snap 

trim over shoulder screws. Align ireplace 

in  mantel  assembly  so  the  trim  overlaps 
mantel evenly on all three sides.

12. Lower bottom louver door. Use 3" wood 

screws provided with mantel accessory 

to attach ireplace to base (see mantel 

instruction sheet).

Side 
Trim

Top Trim 

Mitered Edge

Figure 14 - Assembling Perimeter Trim 

Shim

Set Screws

Adjusting 

Plate 

Slot

Slot

Assembling Perimeter Trim

 

1.  Remove packaging from three remaining 

pieces of trim. 

2.  Locate  two  adjusting  plates  with  set 

screws, and two shims in the hardware 

packet.

3.  Align shim under adjusting plate as shown 

in Figure 14. 

Figure 15 - Removing Upper Louver 

Assembly

Upper Louver 
Assembly 

Black 

Screws

Blower Bracket 

Mounting Holes

Figure 13 - Installing Fireplace into 

Mantel Assembly

4.  Slide  one  end  of  adjusting  plate/shim 

in  slot  on  mitered  edge  of  top  trim  (see 
Figure 14).

5.  Slide  other  end  of  adjusting  plate/shim 

in slot on mitered edge of side trim (see 
Figure 14).

6.  While irmly holding edges of trim together, 

tighten both set screws on the adjusting 

plate with slotted screwdriver. 

7.  Repeat steps 1 through 6 for other corner.
8.  Set  trim  assembly  aside  for  later 

installation.

INSTALLING BLOWER ACCESSORY 

GA3450TA

Removing Upper Louver Assembly

To install the blower accessory, you must irst 

remove the upper louver assembly. 
1.  Lift screen off heater.

2.  Remove 4 screws from louver assembly 

(see Figure 15). Save these screws. 

3.  Pull louver assembly straight out from the 

cabinet. Be careful not to scratch the paint. 

Set louver assembly and screws aside.

Removing Valve Cover Shield 

1.  Open bottom louver assembly by swing

-

ing the assembly down (see Figure 16, 

page 14). 

2.  Using short Phillips screwdriver, remove 

the screw under the center of the branch 

support. Rotate valve cover shield clock-

wise and slide out.

 

IMPORTANT:

  Do  not  remove  shoulder 

screw on the left side of valve cover shield. 

Slide the valve cover shield off of the shoul-

der screw (see Figure 16, page 14). 

Содержание CGCFTNA

Страница 1: ...hone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the ire department Installation and service...

Страница 2: ...ot convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING Thisproductcon tainsand orgenerateschemicals known to the state of Califo...

Страница 3: ...gas indicated on rating plate This appli ance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors propane...

Страница 4: ...ause pilot outage 16 Do not operate fireplace if any log is broken Do not operate ireplace if a log is chipped dime sized or larger 17 To prevent performance problems do not use propane LP fuel tank o...

Страница 5: ...hardware packet 4 Check ireplace for any shipping damage If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 Please do not return product to the store WARNING Always have branch support and s...

Страница 6: ...t and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy eficient your home needs to breathe Fresh air must enter your...

Страница 7: ...h x 8 ft ceiling height 2560 cu ft volume of space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space 30 000...

Страница 8: ...CoMBUsTIoN ANd VeNTIlATIoN Continued Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling a...

Страница 9: ...y sup plied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection ground joint union sediment trap tee joint pipe wrench An equipment...

Страница 10: ...idth and depth of the ireplace CAUTION If you install the ireplace in a home garage ireplace pilot and burner must be at least 18 above loor locateireplacewheremoving vehicle will not hit it For conve...

Страница 11: ...d make all electrical connections 3 Install gas piping to ireplace location This installation includes an approved lexible gas line if allowed by local codes after the equipment shutoff valve The lexi...

Страница 12: ...r is installed install a properly grounded 120 volt three prong electrical outlet at ireplace location if an outlet is not there If possible locate outlet so cabinet mantel will cover it when installe...

Страница 13: ...r Bracket Mounting Holes Figure 13 Installing Fireplace into Mantel Assembly 4 Slide one end of adjusting plate shim in slot on mitered edge of top trim see Figure 14 5 Slide other end of adjusting pl...

Страница 14: ...casing see Figure 17 Plug fan kit into 120 Volt grounded power supply and test operation Installing Blower Assembly CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors c...

Страница 15: ...g found in hardware kit into the hole left by supply cord strain relief 4 A licensed electrician must follow the wir ing diagram to connect incoming electri cal supply to fan kit wiring harness see Fi...

Страница 16: ...ocal codes Use pipe of 1 2 or greater diameter to allow proper gas volume to ireplace If pipe is too small undue loss of volume will occur Propane LP Supply Tank External Regulator Figure 21 External...

Страница 17: ...eplace Branch Support Screen Screen Shipping Screw Shoulder Screw Flexible Gas Line CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL Installation Items Needed Phillips screwdriver sealant resistan...

Страница 18: ...TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply pipin...

Страница 19: ...t fol low these instructions exactly a ire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the...

Страница 20: ...he ireplace screen in place Make sure ire place screen is installed before running ireplace NOTICE Duringinitialoperation of new ireplace burning logs will give off a paper burning smell Orange lame w...

Страница 21: ...struction installation location room size open air temperatures etc Frequent use of your ireplace will let you determine your own comfort levels MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 un...

Страница 22: ...wn in Figure 34 turn ireplace off see To Turn Off Gas to Appliance page 21 see Troubleshooting page 24 Figure 33 Correct Burner Flame Pattern Figure 34 Incorrect Burner Flame Pattern INsPeCTING BURNeR...

Страница 23: ...an Inspect these areas of ireplace before each use Have ireplace inspected yearly by a qualiied service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding ma...

Страница 24: ...osition 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free ignitor cable if pinched by any metal or t...

Страница 25: ...rlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 Hand tighten until snug then tighten 1 4 turn more 6 A Contact local propane LP or natural gas com pany B Clean...

Страница 26: ...nd let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 12 4 Cl...

Страница 27: ...ly clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ventilation...

Страница 28: ...LLC at 1 866 328 4537 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When cal...

Страница 29: ...ERMOSTATICALLY CON TROLLED BLOWER KIT GA3450TA For all models Provides better heat distribu tion Makes ireplace more eficient Automati cally turns off and on as needed CORNER MANTEL WITH FULL HEARTH B...

Страница 30: ...ucts com 124978 01B 30 PARTs MODELS CGCFTPA SHOWN AND CGCFTNA 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 42 16 15 18 24 28 34 25 27 20 4 35 12 24 12 1 14 25 14 40 3 37 26...

Страница 31: ...098303 02 Regulator Screw 2 19 Outer Shell Base 1 20 102649 02 Branch Support 1 21 099415 09 Gas Regulator 1 099415 10 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Pie...

Страница 32: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic m...

Отзывы: