www.fmiproducts.com
124978-01B
11
IMPORTANT:
When inishing your irebox,
combustible materials
WARNING: Do not allow any
combustible/noncombustible
materials to overlap the irebox
front facing.
WARNING: Do not allow
noncombustible materials to
cover any necessary openings
like louvered slots.
WARNING: If pre-wiring, do
not connect wiring to any electri
-
cal source at this time.
Install ireplace electrical outlet
and connect wiring to outlet
before connecting to electrical
source. The ireplace electri
-
cal outlet is included with the
GA3450TA blower accessory.
Only use the ireplace electrical
outlet supplied with the GA3450
-
TA blower accessory.
2. If installing GA3450TA blower accessory,
do so at this time. See
Installing Blower
Accessory GA3450TA,
page 13.
Note: If not installing blower accessory,
you may wish to run electrical wiring to
your ireplace for future blower installa
-
tion (see Accessories, page 29) Use only
approved three-wire electrical wiring.
Note: A qualiied installer should make all
electrical connections.
3. Install gas piping to ireplace location. This
installation includes an approved lexible
gas line (if allowed by local codes) after
the equipment shutoff valve. The lexible
gas line must be the last item installed on
the gas piping.
4. If you have not assembled irebox, follow
instructions on page 4.
5. Carefully set ireplace in front of rough
opening with back of ireplace inside wall
opening.
6. Attach lexible gas line to ireplace gas
regulator. See
Connecting to Gas Supply,
page 16.
7. Bend four nailing langes on outer casing
with pliers (see Figure 10).
8. Attach ireplace to wall studs using nails
or wood screws through holes in nailing
lange.
9. Check all gas connections for leaks. See
Checking Gas Connections
, page 18.
10. If using optional trim kit, install the trim
after inal inishing and/or painting of wall.
See instructions included with trim acces
-
sory for attaching trim.
INsTAllATIoN
Continued
36
5
/
8
"
25
7
/
8
"
51
3
/
4
"
26
7
/
8
"
Figure 9 - Rough Opening for Installing
in Corner
26
7
/
8
"
26
7
/
8
"
3/4" Off
The Floor
Minimum
10
1
/
2
"
Figure 8 - Rough Opening for Installing
in Wall
Figure 10 - Attaching Fireplace to Wall
Studs
Nails or
Wood
Screws
Nailing
Flanges