Thermocouple
Pilot Burner
Figure 31 - Correct Pilot Flame Pattern
(Propane/LP Shown)
Thermocouple
Pilot Burner
Figure 32 - Incorrect Pilot Flame Pattern
(Propane/LP Shown)
BURNER FLAME PATTERN
Figure 33 shows a correct burner lame pat
-
tern. Figure 34 shows an incorrect burner
lame pattern. The incorrect burner lame
pattern shows sporadic, irregular lame tip
-
ping. The lame should not be dark or have
an orange/reddish tinge.
Note: When using ireplace for the irst time,
lame will be orange for approximately 1 hour
until log cures.
If burner lame pattern is incorrect, as shown
in Figure 34
• turn ireplace off (see
To Turn Off Gas to
Appliance
, page 21)
• see
Troubleshooting
, page 24
Figure 33 - Correct Burner Flame Pattern
Figure 34 - Incorrect Burner Flame
Pattern
INsPeCTING BURNeR
Check pilot lame pattern and burner lame
pattern often.
PILOT FLAME PATTERN
Figure 31 shows a correct pilot lame pattern.
Figure 32 shows an incorrect pilot lame pat
-
tern. The incorrect pilot lame is not properly
heating the thermocouple. This will cause
thermocouple to cool. When thermocouple
cools, the ireplace will shut down.
If pilot lame pattern is incorrect, as shown
in Figure 32
• turn ireplace off (see
To Turn Off Gas to
Appliance,
page 21)
• see
Troubleshooting
, page 24
Note: The pilot lame on natural gas units will
have a slight curve, but lame should be blue
and have no yellow or orange color.