• Each fault is displayed one time with the top right hand segment of the dual 7-
segment display activated between faults.
• Each fault is displayed with the most recent fault displayed first.
• A maximum of six individual faults can be stored
• A maximum of three consecutive identical faults are stored.
• A “0” will be displayed with no faults are stored
• The ICC will automatically exit the F
FA
AU
UL
LT
T R
RE
EC
CA
AL
LL
L mode after displaying stored
faults
IIM
MP
PO
OR
RT
TA
AN
NT
T:: The ICC stores the previous six history faults. The complete stored
fault history cannot be displayed using a conventional thermostat.
C
Clle
ea
arr F
Fa
au
ulltt H
Hiis
stto
orry
y ((T
TE
ES
ST
T a
an
nd
d S
SW
W2
2 B
Bu
utttto
on
ns
s))
• Clear FAULT HISTORY by pressing both TEST and SW2 button for five (5) sec-
onds with insulated probes and release.
• The top and bottom segments of the dual 7-segment LEDs flash to indicate the
history has been cleared.
Fault history is cleared with the top and bottom LED
segments flash
8
Fault Recall Mode (TEST and SW2 Buttons)
•
Enter
FAULT RECALL
mode by pressing the
TEST
and
SW2
buttons at the same time
with insulated probes for one (1) second and release.
•
When entering and exiting FAULT RECALL mode the top and bottom segments of the 7-
segment LEDs will illuminate.
Fault Recall Mode – the top and bottom segments illuminated
•
When entering
FAULT RECALL
mode, the ICC will automatically scroll through stored
faults on the 7-segment LEDs.
•
Each fault is displayed one time with the top segment of the 7-segment display activated
between faults.
•
Each fault is displayed with the most recent fault displayed first.
•
A maximum of six individual faults can be stored
•
A maximum of three consecutive identical faults are stored.
•
A “0” will be displayed with no faults are stored
•
The ICC will automatically exit the
FAULT RECALL
mode after displaying stored faults
IMPORTANT:
The ICC stores the previous two weeks of history faults. The complete stored
fault history cannot be displayed using a conventional thermostat.
Clear Fault History (TEST and SW2 Buttons)
•
Clear FAULT HISTORY by pressing both TEST and SW2 button for five (5) seconds with
insulated probes and release.
•
The top and bottom segments of the 7-segment LEDs flash to indicate the history has been
cleared.
Fault history is cleared with the top and bottom LED segments flash
C
O
N
V
E
N
T
IO
N
A
L
T
H
E
R
M
O
S
T
A
T
W
IR
IN
G
36