Страница 1: ...d automatically cutoff in Cool mode if the temperature drops below 45 F 7 C 3 Compressor Protection This thermostat provides a 4 minute delay after shutting off the compressor before it can be restart...

Страница 2: ...or will flash as a reminder to check your system s filter After changing or cleaning the system filter press and hold the Filter key for 3 seconds The display will blink and the counter will be reset...

Страница 3: ...alkaline batteries even if you have recently replaced them Next Move the battery out hold any key then place the battery again You will need to reprogram your thermostat and confirm normal operation I...

Страница 4: ...erminal on your existing thermostat IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard After labeling wires disconnect them from the existing thermostat Remove existing w...

Страница 5: ...wallplate Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate See Figure 4 5 Ignore any wires which may be present but which were note connected to the old th...

Страница 6: ...in the HG position If the Fan does not come on within a minute of the thermostat calling for heating change the switch position to HE The system selector has no effect in the cooling mode NOTE HG posi...

Страница 7: ...ies Auto Fan Does Not Turn On Properly 1 Move HG HE selector to correct position 1 Check that the function switch is in the correct position HEAT or COOL 2 There may be as much as 4 mintue delay befor...