heat 

off 

cool 

system 

on  auto 

fan

 

OPERATION 

Start­up

 

The  LCD  will  show  the  factory  default 

display of 70˚F (21˚C) when batteries are first installed,. The temperature will update 

after a few seconds.

 

System Selector Switch

 

The System Selector switch on the front of the thermostat determines the operating mode of the thermostat. You may select COOL, OFF, HEAT. 

NOTE: Anytime you install or remove the thermostat from the wallplate, slide the System Selector to the OFF position to prevent the possibility of a 

rapid system On – OFF.

 

Fan Switch

 

The Fan switch should normally be located in the AUTO position. The Fan will be turned on along with normal operation of your system. In a normal 

gas or oil furnace, the Fan will be turned on by your furnace after its warm­up delay. For electric heat, air conditioning, and heat pump operation, the 

Fan will turn on with the system. 

To run the Fan on continuously, slide the Fan switch to the ON position.

 

Review Current Set Temperature 

Ÿ

 Press either the up or down key once to see the Set Temperature. 

The factory default is 68˚F (20˚C) when started with the System Switch Off or Heat, and 78˚F (26˚C) when started with the System Switch on Cool.

 

Setting New Temperature 

Ÿ

  Press  either  the  up  or  down  once  and 

display the set temperature. 

Ÿ

 Press either up or down again to change 

to your desired Set Temperature. Hold the key down for  over 2 seconds  to fast  advance 

the Set Temperature. 

The display will return to the normal  room 

temperature after the keys have been released for 5 seconds.

 

Filter Monitor

 

The thermostat counts the number of hours 

your system’s filter has been in use. To maximize your system’s performance and 

energy  efficiency,  change  or  clean  your 

filter regularly. When the total system run time for heat and cool reaches 400 hours, the 

Filter  Change  Indicator  will  flash  as  a 

reminder to check your system’s filter. 

After changing or cleaning the system filter, 

press  and hold the Filter key  for 3 seconds. The  display will blink,  and the counter will 

be reset to zero. 

Note: Pressing the Filter key at any time for less than 3 seconds will cause the Filter Change Indicator to appear on the LCD. This is only to confirm key operation, and 

the counter is not affected unless the key is held for greater than 3 seconds.

 

SPAN Setting

 

Your thermostat is set  at the  factory to cycle  at 2˚F (1˚C)  above  and below the  set temperature. (Span =  2) This  setting  has been designed to provide  a comfortable 

room temperature under most all conditions. However, if you find your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time. 

Ÿ

 Press and hold BOTH up and down keys for three seconds. SPAN will be displayed on the LCD. 

Ÿ

 Press up to raise the Span to 3. This setting INCREASES to cycle time by allowing your system to run LONGER. 

Ÿ

 Press down to lower the Span to 1. This setting DECREASES the cycle time by causing your system to run SHORTER. 

The Span settings remain the same for both HEAT and COOL, and can be changed in any System Switch position. 

CO O L 

O F F 

HE AT 

O N 

AU TO 

SYST EM 

FA N 

Filter Change 
Indicator:Flashes 
when filter needs 
to be checked. 

LCD Display: 
Shows Room 
Temperature,Set 
Temperature,and 
other feature 
information as 
required. 

Light:Backlight 
display 
automatically 
with each key 
press for easy 
viewing. 

Low Battery 
Indicator: 
Flashes when 
batteries need 
to be replaced. 

Front Door: 

Battery cover 
Open with one 
finger from top. 

System 
Switch: 
Selector 
switch for 
Heat,Cool, 
and Off. 

Fan Switch: 
Fan switch 
for Automatic 
or Continuous 
fan operation. 

Filter Key: 
Resets the 
filter change 
counter to zero. 

Up and Down Keys: 
Keys for changing 
the Temperature 
setting. Also used 
for adjusting the 
Span. 

Battery 
Compartment: 
Front access allows 
easy insertion of 
two AA 1.5V 
batteries. 

Front Door: 
Cover keys Open with 
one finger from left or right.

Содержание CP1717

Страница 1: ...d automatically cutoff in Cool mode if the temperature drops below 45 F 7 C 3 Compressor Protection This thermostat provides a 4 minute delay after shutting off the compressor before it can be restart...

Страница 2: ...or will flash as a reminder to check your system s filter After changing or cleaning the system filter press and hold the Filter key for 3 seconds The display will blink and the counter will be reset...

Страница 3: ...alkaline batteries even if you have recently replaced them Next Move the battery out hold any key then place the battery again You will need to reprogram your thermostat and confirm normal operation I...

Страница 4: ...erminal on your existing thermostat IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard After labeling wires disconnect them from the existing thermostat Remove existing w...

Страница 5: ...wallplate Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate See Figure 4 5 Ignore any wires which may be present but which were note connected to the old th...

Страница 6: ...in the HG position If the Fan does not come on within a minute of the thermostat calling for heating change the switch position to HE The system selector has no effect in the cooling mode NOTE HG posi...

Страница 7: ...ies Auto Fan Does Not Turn On Properly 1 Move HG HE selector to correct position 1 Check that the function switch is in the correct position HEAT or COOL 2 There may be as much as 4 mintue delay befor...