Figure 1 

Wiring Labeling 

Ÿ

 Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a 

code latter as shown in Table A below. 

Ÿ

 Note that this thermostat has multiple  function terminals that  allow Single­Stage Heat Pump capability. Standard  systems use: Rh, Rc, G, Y, W. [Single­Stage Heat 

Pumps use: R, Y, G, and O or B.] Table A below shows 

the multiple functions of the terminals. Use the terminals that match your system. 

Ÿ

 The number of wires in your system can be as few as two (for heat only systems), as many as eight, or any number in between. If you follow the labeling procedures 

correctly, you do not have to be concerned about how many wires there are. 

Ÿ

 There is  often no terminal marking  on the  existing thermostat of two wire, heat  only  systems. Just connect  either  of the wires to the  RH terminal, then connect the 

other wire to the W terminal to complete the circuit. 

Ÿ

 IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE SELFADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A BELOW. (For 

example, attach the label marked W to the wire that toes to the W or H terminal on your existing thermostat.) IGNORE THE COLOR OF THE WIRES since these do 

not always comply with the standard. 

Ÿ

After labeling wires, disconnect them from the existing thermostat. 

Ÿ

 Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall. 

Ÿ

 If hole in wall is larger than necessary  for wires, seal this hole with insulating material so that  no hot  or cold  air can  enter the back  of the thermostat from the wall. 

This air could cause a false thermostat reading.

 

Table A 

If the code letter on 

your existing 

Thermostat is 

then mark the wire 

with label shown 

and connect to 

thermostat terminal 

shown

 

NOTE: Do not connect a “Common” wire (sometimes 

labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non­battery 
powered thermostats. 

Mount wallplate and Thermostat 

Ÿ

 Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2. 

RH,R,VR or 4 
24 Volt 
­ or­ 

Reversing Valve operating in Heat mode. 
(Single Stage Heat Pumps ONLY.) 

Reversing Valve operating in Cool mode. 
(Single Stage Heat Pumps ONLY.) 

­ or­ 

24 Volt Cool 

RC,VC 

G or F 
Fan 

Y,Y1,C or M 
Air Conditioning Compressor 

­ or­ 

Single Stage Heat Pump 

Compressor 

W or H 

Heating 


24 Volt 

(Single Stage Heat Pumps ONLY.) 

Rh/B

 

R

 

Rc

/O

 

Rh/B 

Rc/O 

R

Содержание CP1717

Страница 1: ...d automatically cutoff in Cool mode if the temperature drops below 45 F 7 C 3 Compressor Protection This thermostat provides a 4 minute delay after shutting off the compressor before it can be restart...

Страница 2: ...or will flash as a reminder to check your system s filter After changing or cleaning the system filter press and hold the Filter key for 3 seconds The display will blink and the counter will be reset...

Страница 3: ...alkaline batteries even if you have recently replaced them Next Move the battery out hold any key then place the battery again You will need to reprogram your thermostat and confirm normal operation I...

Страница 4: ...erminal on your existing thermostat IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard After labeling wires disconnect them from the existing thermostat Remove existing w...

Страница 5: ...wallplate Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate See Figure 4 5 Ignore any wires which may be present but which were note connected to the old th...

Страница 6: ...in the HG position If the Fan does not come on within a minute of the thermostat calling for heating change the switch position to HE The system selector has no effect in the cooling mode NOTE HG posi...

Страница 7: ...ies Auto Fan Does Not Turn On Properly 1 Move HG HE selector to correct position 1 Check that the function switch is in the correct position HEAT or COOL 2 There may be as much as 4 mintue delay befor...

Страница 8: ......

Отзывы: