Comfort Stat CP1717 Скачать руководство пользователя страница 7

The factory position for this switch is in the STD position. Leave it in this position if you have ANY system that uses gas, oil, electric, or hot water heating. If you have a 

single­stage Heat Pump (no auxiliary or emergency heat source), then slide the switch to the HP position. Be sure the reversing valve wire is connected to the correct 

terminal for your heat pump (Rc/O) or (Rh/B). 

Ÿ

 F˚ / C˚ selector (Fahrenheit / Celsius) 

Your thermostat is set for F˚ mode from the factory. In order to change to C˚ mode, slide the switch to C˚ and hold any key about 2 seconds without the battery, then 

place the battery again

NOTE: Unless press any key about 2 seconds without the battery, then place the battery again.

 

Figure 6 

TROUBLESHOOTING 

Problem 

Solution

 

1. Check battery connections and batteries. 

No Display 

2.  Move  the  battery  out  and  wait  for  about  1 

minutes then Replace Batteries.

Entire 

Display 

Dims. 

1. Replace Batteries. 

Auto Fan Does Not 

Turn On Properly. 

1. Move HG/HE selector to correct position. 

1. Check that the function switch is in the correct 

position (“HEAT” or “COOL”). 

2.  There  may  be  as  much  as  4­mintue  delay 

before  the  system  turns  On  –  wait  and  check. 

(Compressor protection delay.) 

3.  Check  your  circuit  breakers  and  switches  to 

ensure there is power to the system. 

4. Replace batteries. 

5. Make sure your furnace blower door is closed 

properly. 

6.  If  your  non­heat  pump  system  only  uses  4­ 

wires,  be  sure  the  jumper  wire  is  installed 

between the Rh/B and Rc/O terminals. 

7.  Check  the  position    of  the  Reversing  Valve 

selector switch: Standard or Heat Pump. 

Heating  or  Cooling 

Does Not Go On or 

Off. 

8.  If  you  have  single­stage  heat  pump,  be  sure 

the jumper wire is installed between the Y and 

W terminals. 

Erratic Display 

1. Move the battery  out hold  any  key then place 

the battery again. Then reprogram. 

If unit continues to 

operate in the Off 

position. 

1. Replace unit. 

Thermostat 

permanently reads 

“HI”, “LO”, or “Er”. 

1. Replace unit. 


Te mp era tur e 
Di spla y 

S ystem 
S e lecto r 

S TD 

HP 

F an  Op tion 

HG 

HE 

K3 

JP 2 

FA HRE NHE IT 

CE NTIG RA DE 

K5

Содержание CP1717

Страница 1: ...d automatically cutoff in Cool mode if the temperature drops below 45 F 7 C 3 Compressor Protection This thermostat provides a 4 minute delay after shutting off the compressor before it can be restart...

Страница 2: ...or will flash as a reminder to check your system s filter After changing or cleaning the system filter press and hold the Filter key for 3 seconds The display will blink and the counter will be reset...

Страница 3: ...alkaline batteries even if you have recently replaced them Next Move the battery out hold any key then place the battery again You will need to reprogram your thermostat and confirm normal operation I...

Страница 4: ...erminal on your existing thermostat IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard After labeling wires disconnect them from the existing thermostat Remove existing w...

Страница 5: ...wallplate Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate See Figure 4 5 Ignore any wires which may be present but which were note connected to the old th...

Страница 6: ...in the HG position If the Fan does not come on within a minute of the thermostat calling for heating change the switch position to HE The system selector has no effect in the cooling mode NOTE HG posi...

Страница 7: ...ies Auto Fan Does Not Turn On Properly 1 Move HG HE selector to correct position 1 Check that the function switch is in the correct position HEAT or COOL 2 There may be as much as 4 mintue delay befor...

Страница 8: ......

Отзывы: