background image

www.desatech.com

115006-01C

3

SAFETy INFORMATION

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

 WARNING: Keep flue open 

when operating unit.

IMPORTANT:  Read  this  owner’s 

manual carefully and completely 

before trying to assemble, operate 

or service this log set. Improper use 

of this log set can cause serious 

injury  or  death  from  burns,  fire, 

explosion,  electrical  shock  and 

carbon monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon Monoxide Poisoning:

 Early signs of carbon 

monoxide poisoning resemble the flu, with head

-

aches, dizziness or nausea. If you have these signs, 

the log set may not be working properly. 

Get fresh 

air at once!

 Have log set serviced. Some people 

are more affected by carbon monoxide than others. 

These include pregnant women, people with heart 

or lung disease or anemia, those under the influence 

of alcohol and those at high altitudes.

Natural  Gas:

 Natural gas is odorless. An odor-

making agent is added to the gas. The odor helps 

you detect a gas leak. However, the odor added to 

the gas can fade. Gas may be present even though 

no odor exists.

Make certain you read and understand all warnings. 

Keep this manual for reference. It is your guide to 

safe and proper operation of this log set.

  WARNING:  Any  change  to 

this log set or its controls can 

be dangerous.

 WARNING: Do not use a blow-

er insert, heat exchanger insert or 

other accessory not approved for 

use with this appliance.

 WARNING: This appliance is 

equipped for natural gas. An op-

tional propane/LP conversion kit 

model GA9200 must be installed 

for use with propane/LP gas.

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns.

 WARNING: Installed decora-

tive glass door enclosures must 

be fully opened when operating 

this gas appliance.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects on the appliance.

Log set becomes very hot when 

in use. Keep children and adults 

away  from  hot  surface  to  avoid 

burns or clothing ignition. Appli-

ance will remain hot for a time after 

shutdown. Allow surface to cool 

before touching.

Carefully supervise young chil-

dren when they are in the room 

with appliance.

You must operate this appliance 

with a fireplace screen in place. 

Make  sure  fireplace  screen  is 

closed before running appliance.

Keep  the  appliance  area  clear 

and free from combustible ma-

terials, gasoline and other flam-

mable vapors and liquids.

Содержание Sedona LSLR18

Страница 1: ...Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplie...

Страница 2: ...ntilation air must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently lo...

Страница 3: ...d understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its controls can be dangerous WARNING Donot...

Страница 4: ...ammable liquids or vapors are used or stored under dusty conditions 8 Do not burn solid fuel in the fireplace after installing the log set Do not use this log set to cook food or burn paper or other o...

Страница 5: ...al Information Charts The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2 Unpacking Continued 2 Remove all protective packaging applied to logs...

Страница 6: ...within reach for test gauge hook up NPT tap must be upstream from log set see Figure 4 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning o...

Страница 7: ...r Inlet Venturi Attached to Pan Bottom Gas Connector Tube Figure 6 Connecting Gas to Appliance Adapter Fitting Burner Inlet Fitting Factory Installed 3 Check all joints from gas meter to equipment shu...

Страница 8: ...ob serve the individual tongues of flame on the burner Make sure that all ports are clear and producing flame evenly across the burner If any ports appear blocked clear them by removing the burner man...

Страница 9: ...w the safety information column 1 If you don t smell gas go on to the next step 4 Light a match and lay it on top of the pan material about 2 from the end of the sup ply side of the pan 5 Slowly turn...

Страница 10: ...our model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com Replacement Parts Note Use only original replacement parts This will prot...

Страница 11: ...djust damper wide open and or have fireplace and vent ing professionally cleaned and checked 3 Separate the logs to allow more flame passage 4 Removeanyforeignitemsfrom the flame pattern and or check...

Страница 12: ...lace control valve 1 Locate and correct all leaks see Checking Gas Connec tions page 7 OBSERVED PROBLEM Log set produces a clicking tick ing noise just after burner is lit or shut off Log set produces...

Страница 13: ...3 pine cones per box Ash Bed Material Vermiculite GA9750A Not Shown For all models Use for firebox decoration only Glowing embers GA9950A Not Shown For all models Use for firebox decoration only Sili...

Страница 14: ...www desatech com 115006 01C 14 Illustrated Parts Breakdown Models LSLR18 and LSLR24 23 19 18 12 14 11 15 16 13 17 20 21 22 1 8 9 10 3 2 4 5 6 7...

Страница 15: ...242 01 Damper Clamp Std Assy 1 9 11209 Nut 10 24 2 10 114986 04 Log Grate 1 114986 05 Log Grate 1 11 901481 01 Bottom Log 1 109128 02 Bottom Log 1 12 114994 01 Lg Top Log 1 114994 02 Lg Top Log 1 13 1...

Страница 16: ...ed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear...

Отзывы: