CLEANING AND 

MAINTENANCE

•  Keep the area around the log set clean and clear 

of debris.

•  Occasionally, you may use a soft bristle brush 

to clean logs.

•  Once every year a qualified agency or certified 

chimney sweep should examine and clean the 

venting system of the fireplace.

SERVICE HINTS

When Gas Pressure is Too Low

•  pilot will not stay lit

•  burners will have delayed ignition

•  appliance will not produce specified heat

You may feel your gas pressure is too low. If so, 

contact your local natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, 

operation, or troubleshooting. If so, contact DESA’s 

Technical Service Department at 1-866-672-6040. 

When calling please have your model and serial 

numbers of your appliance ready.

You can also visit DESA’s technical services web 

site at 

www.desatech.com

.

REPLACEMENT PARTS

Note

: Use only original replacement parts. This 

will protect your warranty  coverage for parts 

replaced under warranty. 

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they 

can’t supply original replacement part(s), call DESA’s 

Technical Service Department at 1-866-672-6040. 

When calling DESA, have ready

•  your name and address

•  model and serial numbers of your log set 

•  how log set was malfunctioning

•  type of gas used (propane/LP or natural gas)

•  purchase date

Usually, we will ask you to return the part to the 

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they 

can’t supply original replacement part(s), call 

DESA at 1-866-672-6040 for referral information. 

When calling DESA, have ready

•  model number of your log set 

•  the replacement part number

Содержание Sedona LSLR18

Страница 1: ...Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplie...

Страница 2: ...ntilation air must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently lo...

Страница 3: ...d understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its controls can be dangerous WARNING Donot...

Страница 4: ...ammable liquids or vapors are used or stored under dusty conditions 8 Do not burn solid fuel in the fireplace after installing the log set Do not use this log set to cook food or burn paper or other o...

Страница 5: ...al Information Charts The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2 Unpacking Continued 2 Remove all protective packaging applied to logs...

Страница 6: ...within reach for test gauge hook up NPT tap must be upstream from log set see Figure 4 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning o...

Страница 7: ...r Inlet Venturi Attached to Pan Bottom Gas Connector Tube Figure 6 Connecting Gas to Appliance Adapter Fitting Burner Inlet Fitting Factory Installed 3 Check all joints from gas meter to equipment shu...

Страница 8: ...ob serve the individual tongues of flame on the burner Make sure that all ports are clear and producing flame evenly across the burner If any ports appear blocked clear them by removing the burner man...

Страница 9: ...w the safety information column 1 If you don t smell gas go on to the next step 4 Light a match and lay it on top of the pan material about 2 from the end of the sup ply side of the pan 5 Slowly turn...

Страница 10: ...our model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com Replacement Parts Note Use only original replacement parts This will prot...

Страница 11: ...djust damper wide open and or have fireplace and vent ing professionally cleaned and checked 3 Separate the logs to allow more flame passage 4 Removeanyforeignitemsfrom the flame pattern and or check...

Страница 12: ...lace control valve 1 Locate and correct all leaks see Checking Gas Connec tions page 7 OBSERVED PROBLEM Log set produces a clicking tick ing noise just after burner is lit or shut off Log set produces...

Страница 13: ...3 pine cones per box Ash Bed Material Vermiculite GA9750A Not Shown For all models Use for firebox decoration only Glowing embers GA9950A Not Shown For all models Use for firebox decoration only Sili...

Страница 14: ...www desatech com 115006 01C 14 Illustrated Parts Breakdown Models LSLR18 and LSLR24 23 19 18 12 14 11 15 16 13 17 20 21 22 1 8 9 10 3 2 4 5 6 7...

Страница 15: ...242 01 Damper Clamp Std Assy 1 9 11209 Nut 10 24 2 10 114986 04 Log Grate 1 114986 05 Log Grate 1 11 901481 01 Bottom Log 1 109128 02 Bottom Log 1 12 114994 01 Lg Top Log 1 114994 02 Lg Top Log 1 13 1...

Страница 16: ...ed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear...

Отзывы: