Comfort Glow Brentwood LCF18 Скачать руководство пользователя страница 9

www.desatech.com

115043-01D

9

INSTALLATION

Continued 

OPTIONAL GA9050A ON/OFF 
SAFETY VALVE/PILOT KIT 

For  additional  convenience  and  safety,  or  for 

propane/LP  conversion,  an  optional  ON/OFF 

safety valve/pilot kit is available. See 

Accessories

page 18.

 WARNING: You must use a 

ON/OFF safety valve/pilot kit for 

propane/LP conversion.

TESTING BURNER FOR LEAKS

1.  Generously apply noncorrosive leak detec-

tion fluid to all connections.

 WARNING: Never check for 

gas leaks with open flame.

2.  Light the burner with the shutoff valve no 

more than half open and holding a match 

slightly  in  front  of  the  pan  (see 

Lighting 

Instructions

, page 10).

3.  Inspect all connections for bubbles, raw gas 

odor, or flame from any area other than the 

burner (leaks). If leaks are detected, shut off 

the gas valve immediately. Tighten, or reas-

semble the loose connection(s) using pipe joint 

compound until burner system is leak free.

4.  When  the  burner  is  tested  and  leak  free, 

observe the individual tongues of flame on 

the burner. 

Note:

 The burner design includes 

more ports on the outside of the bar. Make 

sure that all ports are clear and producing 

flame evenly across the burner. If any ports 

appear blocked, clear them by removing the 

burner manifold and reaming the ports with a 

modified paper clip or other suitable tool.

5.  When finished testing, turn the gas shutoff 

valve OFF to extinguish all flames.

ADDING PAN MATERIAL

1.  Open the bag of ash bed material (vermiculite) 

and spread it evenly across the burner pan 

to the top. You may overflow the front and 

sides of the pan to cover the entire pan and 

connecting hardware. Do not cover GA9050A 

or GA9150A valve.

2.  Open the glowing embers and evenly cover the 

ash bed material (vermiculite) in the burner pan.

INSTALLING THE GRATE AND LOGS

1.  Place the grate over the burner pan where the 

two outer horizontal supports on the grate fit 

into the two pan positioning notches in the 

rear vertical edge of the pan.

2.  Slide the two rear log grate steps over the 

two outer horizontal supports on the grate as 

shown in Figure 8.

3.  Place the back log onto the grate steps (see 

Figure 9).

4.  Place the front log(s) on the grate and slide 

forward against the front bars on the grate 

(see Figure 9).

5.  Place three middle logs on top of bottom logs 

(see Figure 10, page 10). 

6.  Place the smaller top logs onto the bottom logs 

(see Figure 11, page 10). Leave as much open 

space between logs as possible to minimize 

flame impingement and sooting. 

Note:

 Logs 

may chip if they are handled roughly or if hit 

together while being placed.

Figure 8 - Installing Grate (Pan Material 

Not Shown) 

Grate

Grate steps

Figure 9 - Installing Bottom Logs 

Содержание Brentwood LCF18

Страница 1: ...o not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 2: ...must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufact...

Страница 3: ...micals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep flue open when operating unit IMPORTANT Read this owner s manual carefully and complete...

Страница 4: ...tion 5 3 Air for Combustion and Ventilation 7 Do not run log set where flammable liquids or vapors are used or stored under dusty conditions 8 Do not burn solid fuel in the fireplace after installing...

Страница 5: ...iance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 Installation CAUTION Donotremovethe dataplatesattachedtotheburner pan The dat...

Страница 6: ...Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into the room extinguish the flame and remove any obstruction until proper venting is achieved The...

Страница 7: ...em between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set controls I...

Страница 8: ...Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional GA905...

Страница 9: ...ifold and reaming the ports with a modified paper clip or other suitable tool 5 When finished testing turn the gas shutoff valve OFF to extinguish all flames Adding Pan Material 1 Open the bag of ash...

Страница 10: ...y call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department LIGHTING INSTRUCTIONS 1 STOP Read the safety info...

Страница 11: ...the first time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not pop up when rel...

Страница 12: ...have your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com Replacement Parts Note Use only original replacement parts This wi...

Страница 13: ...s to produce moderate levels of carbon soot where flames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner flame...

Страница 14: ...LEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but flame goes out when control knob is released GA9050A Only Burner does not light after pilot is...

Страница 15: ...person 1 Open flue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Страница 16: ...www desatech com 115043 01D 16 Illustrated Parts Breakdown Models LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Страница 17: ...Manifold 1 6 901137 01 Burner Pan 1 901137 02 Burner Pan 1 7 901242 01 Damper Clamp Std Assy 1 8 101628 01 Gas Line 10 Flex 1 9 901431 01 Grate Steps 2 10 901246 01 Log Grate 1 901246 02 Log Grate 1...

Страница 18: ...ve Pilot Kit GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion Individual Round Log GA9450A Not Shown For decorative purposes only No...

Страница 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 20: ...this warranty The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in o...

Отзывы: