10

INSTALLATION

Continued 

Figure 11 - Installing Top Logs 

Figure 10 - Installing Middle Logs 

OPERATING APPLIANCE

FOR YOUR SAFETY

READ BEFORE LIGHTING

 WARNING: Keep flue open 

when operating unit.

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

BEFORE LIGHTING smell all around  the 

appliance area for gas. Be sure to smell next to 

the floor because some gas is heavier than air 

and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electric switch; do not use 

any phone in your building.

•  Immediately call your gas supplier from a 

neighbor’s phone. Follow the gas supplier’s 

instructions.

•  If you cannot reach your gas supplier, call 

the fire department.

LIGHTING 

 INSTRUCTIONS

1.  STOP! Read the safety information, above.

2.  Turn the gas shutoff valve to OFF.

3.  Wait five (5) minutes to clear out any gas. If 

you then smell gas STOP! Follow the safety 

information above. If you don't smell gas, 

go on to the next step.

4.  Light a match and lay it on top of the pan 

material about 2" from the end of the sup

-

ply side of the pan

5.  Slowly turn the gas shutoff valve ON until 

the burner ignites. If the burner doesn’t 

ignite within 10 seconds with the match 

burning, turn the shutoff valve OFF and 

repeat steps 1 through 4 again.

GAS SHUTOFF 

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning the gas 

shutoff valve counterclockwise 

 to open or 

clockwise 

 to close, as necessary.

Содержание Brentwood LCF18

Страница 1: ...o not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 2: ...must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufact...

Страница 3: ...micals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep flue open when operating unit IMPORTANT Read this owner s manual carefully and complete...

Страница 4: ...tion 5 3 Air for Combustion and Ventilation 7 Do not run log set where flammable liquids or vapors are used or stored under dusty conditions 8 Do not burn solid fuel in the fireplace after installing...

Страница 5: ...iance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 Installation CAUTION Donotremovethe dataplatesattachedtotheburner pan The dat...

Страница 6: ...Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into the room extinguish the flame and remove any obstruction until proper venting is achieved The...

Страница 7: ...em between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set controls I...

Страница 8: ...Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional GA905...

Страница 9: ...ifold and reaming the ports with a modified paper clip or other suitable tool 5 When finished testing turn the gas shutoff valve OFF to extinguish all flames Adding Pan Material 1 Open the bag of ash...

Страница 10: ...y call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department LIGHTING INSTRUCTIONS 1 STOP Read the safety info...

Страница 11: ...the first time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not pop up when rel...

Страница 12: ...have your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com Replacement Parts Note Use only original replacement parts This wi...

Страница 13: ...s to produce moderate levels of carbon soot where flames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner flame...

Страница 14: ...LEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but flame goes out when control knob is released GA9050A Only Burner does not light after pilot is...

Страница 15: ...person 1 Open flue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Страница 16: ...www desatech com 115043 01D 16 Illustrated Parts Breakdown Models LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Страница 17: ...Manifold 1 6 901137 01 Burner Pan 1 901137 02 Burner Pan 1 7 901242 01 Damper Clamp Std Assy 1 8 101628 01 Gas Line 10 Flex 1 9 901431 01 Grate Steps 2 10 901246 01 Log Grate 1 901246 02 Log Grate 1...

Страница 18: ...ve Pilot Kit GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion Individual Round Log GA9450A Not Shown For decorative purposes only No...

Страница 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 20: ...this warranty The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in o...

Отзывы: