Comfort Glow Brentwood LCF18 Скачать руководство пользователя страница 11

www.desatech.com

115043-01D

11

Shutting Off Appliance

Turn gas shutoff valve clockwise 

 to the 

OFF position.

CURING 

LOGS

During the 2-3 hour appliance break-in period, 

you may detect an odor from the appliance 

as the various paints and compounds used in 

the manufacturing of this log set cure. This is 

a normal and temporary situation that is not 

cause for alarm. However, you may want to 

provide extra ventilation to the room during 

this time.

To ensure proper curing of the logs:

•  Ignite  a  2"  flame  and  maintain  it  for  1 

hour.

•  Burn the logs in consecutive 1 hour periods 

raising the flame an additional 2" to full 

flame height for a total of three hours.

OPERATING 

INSTRUCTIONS  

FOR GA9050A

Note:

 Operation instructions for GA9150A 

Remote Ready Valve/Pilot Kit will be included 

with the kit.

1.  STOP! Read the safety information, page 10.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Press in and turn control knob clockwise  

 to the OFF position.

4.  Wait five (5) minutes to clear out any gas. 

Then smell for gas around log set and near 

floor. If you smell gas, STOP! Refer to the 

National Fuel Gas Codes, ANSI Z233.1/

NFPA 54, Section 5.3, Air for Combustion 

and Ventilation.

 If you don’t smell gas, go 

to the next step.

5.   Turn control knob counterclockwise 

  

to the PILOT position and press in. Keep 

control knob pressed in for five (5) seconds.

 

Note:

 You may be running this log set for 

the first time after hooking up to gas sup

-

ply. If so, the control knob may need to be 

pressed in for 30 seconds. This will allow 

air to bleed from the gas system.

• If control knob does not pop up when 

released, contact a qualified service person 

or gas supplier for repairs.

OPERATING APPLIANCE

Continued

6.  With control knob pressed in, push down 

and release ignitor button. This will light 

pilot. The pilot is attached to the rear of 

the front burner. If needed, keep pressing 

ignitor button until pilot lights.

 

Note:

 If pilot does not stay lit, contact a 

qualified service person or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. 

7.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

 

Note:

  If  pilot  goes  out,  repeat  steps  3 

through 7.

8.  Turn control knob counterclockwise  

  

to 

the

 ON position. Burner should light. If 

burner does not light, call a qualified service 

person.

9.  To leave pilot lit and shut off burners only, 

turn control knob clockwise 

 to the 

PILOT position.

ignitor

Control Knob

Pilot

FROM "PiLOT" POsiTiOn

sLiGHT PUsH TO 

TURn OFF 

PULL PUsH 

TO LiGHT

On

O

n

FROM "P

iLOT" PO

si

T

iO

n

s

LiGHT
 PU
s

T

TUR

n

 OFF 

PULL

 PU
s

T

O L
iGHT

FROM "P

iLOT" PO

si

T

iO

n

s

Li

GHT

 PU

s

T

TUR

n

 OFF 

PULL

 PU

s

T

O L

iGHT

O

n

OFF

On

Off

OFF

OFF

Figure 12 - Ignitor and Control Knob

Figure 13 - Thermocouple and Pilot

Pilot 
Burner

Thermocouple

TO TURN OFF GAS 

TO APPLIANCE

Shutting Off Appliance

1.  Turn control knob clockwise 

 to the 

PILOT position.

2.  Press in and turn control clockwise 

 

to the OFF position. 

3.  Close equipment shutoff valve.

Содержание Brentwood LCF18

Страница 1: ...o not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 2: ...must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufact...

Страница 3: ...micals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep flue open when operating unit IMPORTANT Read this owner s manual carefully and complete...

Страница 4: ...tion 5 3 Air for Combustion and Ventilation 7 Do not run log set where flammable liquids or vapors are used or stored under dusty conditions 8 Do not burn solid fuel in the fireplace after installing...

Страница 5: ...iance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 Installation CAUTION Donotremovethe dataplatesattachedtotheburner pan The dat...

Страница 6: ...Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into the room extinguish the flame and remove any obstruction until proper venting is achieved The...

Страница 7: ...em between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set controls I...

Страница 8: ...Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional GA905...

Страница 9: ...ifold and reaming the ports with a modified paper clip or other suitable tool 5 When finished testing turn the gas shutoff valve OFF to extinguish all flames Adding Pan Material 1 Open the bag of ash...

Страница 10: ...y call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department LIGHTING INSTRUCTIONS 1 STOP Read the safety info...

Страница 11: ...the first time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not pop up when rel...

Страница 12: ...have your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com Replacement Parts Note Use only original replacement parts This wi...

Страница 13: ...s to produce moderate levels of carbon soot where flames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner flame...

Страница 14: ...LEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but flame goes out when control knob is released GA9050A Only Burner does not light after pilot is...

Страница 15: ...person 1 Open flue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Страница 16: ...www desatech com 115043 01D 16 Illustrated Parts Breakdown Models LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Страница 17: ...Manifold 1 6 901137 01 Burner Pan 1 901137 02 Burner Pan 1 7 901242 01 Damper Clamp Std Assy 1 8 101628 01 Gas Line 10 Flex 1 9 901431 01 Grate Steps 2 10 901246 01 Log Grate 1 901246 02 Log Grate 1...

Страница 18: ...ve Pilot Kit GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion Individual Round Log GA9450A Not Shown For decorative purposes only No...

Страница 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 20: ...this warranty The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in o...

Отзывы: