background image

5

INSTALLATION

 & USE

PARTS DETAIL

GT Removable Hardware

PT Removable Hardware - 

with either 7” or 3” Hardware Stem

Mounting Hardware

Additional Hardware

Support Pads 

Posterior Mounting 

Block

Anterior Mounting 

Block

Permobil A Mounting 

Block

Permobil B Mounting 

Block

Quantum A Mounting 

Block

¼

“ Spacer Plate

Lateral Hardware

Mid-6 Hardware

Lat-6 Hardware

Mid-8 Hardware

Lat-8 Hardware

Max-8 Hardware

Acta-Relief

 HS Mounting Bracket Only

Acta-Relief

 HS Mounting Bracket 

with Mounting Block

Tool-Less Wing Lock

Extra 2” Link

Extra 3” Link

Extra 4” Link

Mid-line Hardware

BodiLink

®

 Head Support (HS) Hardware and Pads

BodiLink

®

 HS Basic Pads

6”W x 5”L

8”W x 5”L

10”W x 6”L

12”W x 6”L

14”W x 6”L

18”W x 6”L

BodiLink

®

 HS Premium Pads

6”W x 3”L

8”W x 4”L

10”W x 5”L

12”W x 5”L

14”W x 5”L

18”W x 5”L

For Posterior & Anterior 
Mounting Blocks

For PT Hardware Only

For PT Hardware Only

Corpus Back Supports 
23” - 28”H

Corpus Back Supports 20”H

For PT Hardware Only

For PT Hardware Only

TRU-Comfort

2

 Back Supports

7” Stem

3” Stem

Содержание BodiLink Basic Pad BL-HSP3-10W6L

Страница 1: ...USER GUIDE MANUAL COMFORTCOMPANY COM BODILINK HEAD SUPPORT UM BODILINK HEAD SUPPORT REV0218 ...

Страница 2: ...Hardware 13 Adding a Link to the PT Hardware 14 Installing Tool Less Wing Lock on PT Hardware 15 Connecting Hardware to Support Pads any style 16 Adjustments 16 20 Support Pad Positioning any pad and hardware 16 GT Style Hardware 18 PT Style Hardware 19 Finishing Installation any hardware 20 CLEANING AND MAINTENANCE Cleaning 21 Inspection 22 Reuse 22 Storage 22 Disposal 22 WARRANTY AND REPLACEMENT...

Страница 3: ... is noted During the first few hours of use a healthcare professional should be available to observe skin condition and assess the likelihood of skin breakdown During regular use periodically check for skin discoloration and or irritation If discol oration should occur and not disappear after 30 minutes of non use discontinue use and consult with your healthcare provider immediately DO NOT place a...

Страница 4: ...comfort as well as durability This product passed crash testing However when possible do not use head support during transport Repeated or excessive force braking or crash could potentially change adjustment or cause extra wear shortening the life of the product Use after a crash is not recommended ATTENTION Always check that the gear teeth in each joint of are aligned for full tooth engagement be...

Страница 5: ...Relief HS Mounting Bracket Only Acta Relief HS Mounting Bracket with Mounting Block Tool Less Wing Lock Extra 2 Link Extra 3 Link Extra 4 Link Mid line Hardware BodiLink Head Support HS Hardware and Pads BodiLink HS Basic Pads 6 W x 5 L 8 W x 5 L 10 W x 6 L 12 W x 6 L 14 W x 6 L 18 W x 6 L BodiLink HS Premium Pads 6 W x 3 L 8 W x 4 L 10 W x 5 L 12 W x 5 L 14 W x 5 L 18 W x 5 L For Posterior Anteri...

Страница 6: ... of holes on back support shell G and double nuts F Note Use of spacer plate E is optional If not using shorter screws are provided to replace C 5 Replace screws C and washers D and tighten 6 Replace and secure back support cover 7 Insert hardware stem into mounting block B and turn knob A clockwise to secure Note Make sure at least of hardware stem is completely through the bottom of B at all tim...

Страница 7: ...holes on the back support shell G 5 Attach B and F with screws D and washers E from the front face of the back support shell G and tighten 6 Replace and secure back support cover 7 Insert hardware stem C into mounting block B and turn knob A clockwise to secure Note Make sure at least of stem C is completely through the bottom of B at all times See pages 16 20 for final adjustments 1 Loosen screws...

Страница 8: ... Align mounting block B and spacer plate E with desired set of holes on head support bracket H and double nuts F 5 Replace screws C and washers D and tighten 6 Insert hardware stem into mounting block B and turn knob A clockwise to secure Note Make sure at least of hardware stem is completely through the bottom of B at all times See pages 16 20 for final adjustments 1 Align holes on back support s...

Страница 9: ...B Note Use of spacer plate F is optional and may affect clearance in certain recline situations If not using the spacer plate shorter screws are provided to replace D 3 Align mounting block B with desired set of head support holes on power mount bracket H and double nuts G 4 Replace screws D and washers E and tighten 5 Insert hardware stem C into mounting block B and turn knob A clockwise to secur...

Страница 10: ...wise to release it and set aside 2 Using 5mm hex key loosen but not remove screws D to create a gap between double nuts E and mounting block B 3 Slide double nuts E into Uni Track System slots and move into position 4 Tighten screws D with 5mm hex key to secure 5 Insert hardware stem C into mounting bracket B and turn knob A clockwise to secure Note Make sure at least of stem C is completely throu...

Страница 11: ...ng bracket E with head support holes on back support shell G and double nuts F 5 Replace screws C and washers D and tighten 6 Replace and secure back support cover 7 Insert hardware stem into mounting block B and turn knob A clockwise to secure Note Make sure at least of hardware stem is completely through the bottom of B at all times See pages 16 20 for final adjustments 1 Remove screws G and was...

Страница 12: ...rt G with socket head screws E and tighten using 4mm allen wrench 3 Insert hardware stem into mounting bracket B and turn knob A clockwise to secure Note Make sure at least of stem is completely through the bottom of B at all times See pages 16 20 for final adjust ments E C Alternate option when using Quantum Mounting Block Instructions to be used in combination with images above Alternate Mountin...

Страница 13: ...ware stem C 180 so the visible gear teeth are facing the opposite direction 4 Insert hardware stem C into mounting bracket B and turn knob A clockwise to secure Note Make sure at least of stem C is completely through the bottom of B at all times 1 4 2 3 C A C E F D 5 Align extra link G with gear teeth on hardware stem C in the orientation shown below and fasten with safety washer H and screw J 6 A...

Страница 14: ...untersunk side of all taper inserts C should consistently face the same direction on hardware so that screws A are all on the same side 4 Insert screw A and safety washer B into countersunk side of taper insert C and tighten Hold the threaded side of taper insert C firmly while fastening 5 Align new link F joint with ball link E 6 Place new taper insert G halves countersunk side first in the end o...

Страница 15: ... D and the remaining countersunk half of C are aligned inside for a low profile fit in the joint 3 Insert wing lock E and safety washer F into taper lock C half and tighten Hold the taper lock D firmly while fastening 4 Align retainer clip G with tip of wing lock E and press on hard The convex side of the retainer clip must face out Note the retainer clip is very difficult to remove once installed...

Страница 16: ... 2 14W x 5L Premium Pad Without Cover and GT Hardware Shown Gear Tooth Alignment 1 Loosen all hardware adjustment point screws allowing for full articulation of the head support to a desired position Loose screws A around ring B will allow pad orientation adjustment Note Premium BodiLink head support pads are de signed to be used in any orientation including flipped 180º as shown 2 PREMIUM PADS To...

Страница 17: ...s also have lateral positioning features For GT Hardware see page 18 For PT hardware see page 19 Amount of height adjustment available is dependent on the stem length ordered GT Hardware Mid line Positioning Only Mid 6 Lat 6 Mid 8 Lat 8 Max 8 Mid line Positioning Only Lateral Positioning Available Lateral Positioning Available PT Hardware Lateral GT Hardware with Additional Link Shown Max 8 PT Har...

Страница 18: ...ffset D Depth H Height 1 Loosen all hardware adjustment point screws allowing for full articulation of the head support to a desired position 2 Hold hardware and pad in place while tightening each joint Note that adjustments may be affected by each other as gear teeth engage and require compensation from other joints before final tightening ATTENTION It is crucial that gear teeth in all joints are...

Страница 19: ...itioning adjustments A Angle Lateral Offset D Depth H Height Standard Taper Inserts Tool Less Wing Locks not pictured A D D H 1 Loosen all hardware adjustment point screws allowing for full articulation of the head support to a desired position 2 Hold hardware and pad in place while tightening each joint 1 Turn wing lock s counter clockwise to loosen hardware adjustment points allowing for articul...

Страница 20: ...A 2 Slide collar A on hardware stem C to meet the top of mounting bracket B 3 Tighten set screw D in the collar with 2mm hex key until contact is made with the hardware stem This allows for easy positioning of the hardware if it is removed and then replaced Note Collar A is retained in a track in stem C If the collar needs to be removed remove the set screw E located in the track at the bottom of ...

Страница 21: ...y thorough rinse Follow directions on bleach container Let dry completely before use Soiled foams should be replaced Remove cover dab foam with water only cloth and let dry completely before replacing cover Foam should not be exposed to light for any extended period of time Light will cause discoloration of the foam This only effects the appearance of the foam not the functional features There is ...

Страница 22: ...ompany com registration to activate Lifetime Guarantee If manufacturing defects should occur discontinue use immediately Wear from regular use is not considered a manufacturing defect Re placement parts are available by contacting Customer Service or your supplier distributor or retailer Any alterations made to the product or defects caused by irregular use voids the warranty We can only guarantee...

Страница 23: ...23 CLEANING MAINTENANCE THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 24: ...il is a registered trademark of Permobil Inc Quantum is a registered trademark of Pride Mobility Products Corporation GlideWear is a registered trademark of Tamarack Habilitation Technologies Inc Viscool is a registered trademark of American Excelsior Company BLOG Stay connected to related news and updates through these resources www comfortcompany com stay_connected www comfortcompany com UM BODI...