Comfort Company BodiLink Basic Pad BL-HSP3-10W6L Скачать руководство пользователя страница 3

3

 SAFETY GUIDELINES

SAFETY GUIDELINES

SAFETY SYMBOLS

GENERAL SAFETY 

PLEASE NOTE

CARE SYMBOLS

Warning!

Prohibited! 

Wash Cover Only

 - 

Warm Cycle (Maximum Temperature)

Do Not Bleach

No Smoking 

Do Not Expose

 to sources of excessive heat such as open flame or spark.

Bleach Okay

Tumble Dry Low

Do Not Tumble Dry, Steam Clean or 
Autoclave

Air Dry Only
Hang to Dry

Do Not Iron

Antibacterial or Disinfectant Spray

Detailed cleaning instructions on page 21

Wipe with Water Only

 

Do Not Wash

Hand Wash

Do Not Cut 
or Puncture

Although this product meets flammability requirements, we do not 

recommend smoking while using this product. Damage from smoke and 

flame is not covered by the lifetime warranty. You must consider additional 

safety precautions when choosing to smoke while using this product. 

Avoid sharp objects. Do not modify the product. Doing so will void its 

warranty and may lead to personal injury or alter the effectiveness of the 

product by increasing the risk factors for skin breakdown and/or instability.

Indicates actions that should NOT be performed at any time under any 

circumstance. These actions could result in personal injury and/or damage 

to the product or equipment being used.

Without following the specified procedure, this indicates potentially 

hazardous conditions that could lead to personal injury, inadequate 

performance, product damage or malfunction.  

You must 

READ and FOLLOW

 all instructions, notes and warnings included in this 

manual. Understanding how to care for your product is the key to safe and proper 

use. Share this information with all caretakers to help them meet your healthcare 

needs and ensure your safety.

Check packaging and inspect all parts for damage before use. DO NOT USE if dam-

aged and contact 

Comfort Company

 immediately for further instruction. Check reg-

ularly for loose components and tighten as necessary. Contact 

Comfort Company

 if 

wear or damage is noted. 

During the first few hours of use, a healthcare professional should be available to 

observe skin condition and assess the likelihood of skin breakdown. 

During regular use, periodically check for skin discoloration and/or irritation. If discol-

oration should occur and not disappear after 30 minutes of non-use, discontinue use 

and consult with your healthcare provider immediately.

DO NOT place anything in between the user and the product. Additional materials 

may reduce the effectiveness of the product and increase risk factors for skin break-

down and instability.

Always use the cover and base with any inserts as a complete assembly. Never use a 

cover other than one intended for your specific product and size. 

Installing alternate parts to your wheelchair may change the intended structure and 

function of the equipment. Be sure to assess the need for additional safety features 

for your chair such as anti-tip bars or other available options in order to maintain 

stability during use. Use this manual in conjunction with the user manual that came 

with your chair to ensure safety guidelines are being met.

Comfort Company

 cannot be held responsible for damages or injury due to misuse 

of the product or failure to follow instructions provided in this manual. Please contact 

us if you require further assistance in understanding cautions, warnings or instructions 

for using or maintaining your product. 

The directions provided will help to maintain and extend the 

life of your product and ensure it is covered by the 

Comfort 

Company Lifetime Guarantee

. Please see complete warranty 

information on page 22.

The information in this manual was gathered and recorded with 

the latest specifications available at the time of publication. Due 

to our continued effort to reassess and improve our products, 

information found in this manual such as drawings and notes may 

vary slightly from the product that you purchased. We reserve the 

right to make changes to products as they are deemed neces-

sary. To check for the latest version of this manual please visit us 

at www.comfortcompany.com.

Содержание BodiLink Basic Pad BL-HSP3-10W6L

Страница 1: ...USER GUIDE MANUAL COMFORTCOMPANY COM BODILINK HEAD SUPPORT UM BODILINK HEAD SUPPORT REV0218 ...

Страница 2: ...Hardware 13 Adding a Link to the PT Hardware 14 Installing Tool Less Wing Lock on PT Hardware 15 Connecting Hardware to Support Pads any style 16 Adjustments 16 20 Support Pad Positioning any pad and hardware 16 GT Style Hardware 18 PT Style Hardware 19 Finishing Installation any hardware 20 CLEANING AND MAINTENANCE Cleaning 21 Inspection 22 Reuse 22 Storage 22 Disposal 22 WARRANTY AND REPLACEMENT...

Страница 3: ... is noted During the first few hours of use a healthcare professional should be available to observe skin condition and assess the likelihood of skin breakdown During regular use periodically check for skin discoloration and or irritation If discol oration should occur and not disappear after 30 minutes of non use discontinue use and consult with your healthcare provider immediately DO NOT place a...

Страница 4: ...comfort as well as durability This product passed crash testing However when possible do not use head support during transport Repeated or excessive force braking or crash could potentially change adjustment or cause extra wear shortening the life of the product Use after a crash is not recommended ATTENTION Always check that the gear teeth in each joint of are aligned for full tooth engagement be...

Страница 5: ...Relief HS Mounting Bracket Only Acta Relief HS Mounting Bracket with Mounting Block Tool Less Wing Lock Extra 2 Link Extra 3 Link Extra 4 Link Mid line Hardware BodiLink Head Support HS Hardware and Pads BodiLink HS Basic Pads 6 W x 5 L 8 W x 5 L 10 W x 6 L 12 W x 6 L 14 W x 6 L 18 W x 6 L BodiLink HS Premium Pads 6 W x 3 L 8 W x 4 L 10 W x 5 L 12 W x 5 L 14 W x 5 L 18 W x 5 L For Posterior Anteri...

Страница 6: ... of holes on back support shell G and double nuts F Note Use of spacer plate E is optional If not using shorter screws are provided to replace C 5 Replace screws C and washers D and tighten 6 Replace and secure back support cover 7 Insert hardware stem into mounting block B and turn knob A clockwise to secure Note Make sure at least of hardware stem is completely through the bottom of B at all tim...

Страница 7: ...holes on the back support shell G 5 Attach B and F with screws D and washers E from the front face of the back support shell G and tighten 6 Replace and secure back support cover 7 Insert hardware stem C into mounting block B and turn knob A clockwise to secure Note Make sure at least of stem C is completely through the bottom of B at all times See pages 16 20 for final adjustments 1 Loosen screws...

Страница 8: ... Align mounting block B and spacer plate E with desired set of holes on head support bracket H and double nuts F 5 Replace screws C and washers D and tighten 6 Insert hardware stem into mounting block B and turn knob A clockwise to secure Note Make sure at least of hardware stem is completely through the bottom of B at all times See pages 16 20 for final adjustments 1 Align holes on back support s...

Страница 9: ...B Note Use of spacer plate F is optional and may affect clearance in certain recline situations If not using the spacer plate shorter screws are provided to replace D 3 Align mounting block B with desired set of head support holes on power mount bracket H and double nuts G 4 Replace screws D and washers E and tighten 5 Insert hardware stem C into mounting block B and turn knob A clockwise to secur...

Страница 10: ...wise to release it and set aside 2 Using 5mm hex key loosen but not remove screws D to create a gap between double nuts E and mounting block B 3 Slide double nuts E into Uni Track System slots and move into position 4 Tighten screws D with 5mm hex key to secure 5 Insert hardware stem C into mounting bracket B and turn knob A clockwise to secure Note Make sure at least of stem C is completely throu...

Страница 11: ...ng bracket E with head support holes on back support shell G and double nuts F 5 Replace screws C and washers D and tighten 6 Replace and secure back support cover 7 Insert hardware stem into mounting block B and turn knob A clockwise to secure Note Make sure at least of hardware stem is completely through the bottom of B at all times See pages 16 20 for final adjustments 1 Remove screws G and was...

Страница 12: ...rt G with socket head screws E and tighten using 4mm allen wrench 3 Insert hardware stem into mounting bracket B and turn knob A clockwise to secure Note Make sure at least of stem is completely through the bottom of B at all times See pages 16 20 for final adjust ments E C Alternate option when using Quantum Mounting Block Instructions to be used in combination with images above Alternate Mountin...

Страница 13: ...ware stem C 180 so the visible gear teeth are facing the opposite direction 4 Insert hardware stem C into mounting bracket B and turn knob A clockwise to secure Note Make sure at least of stem C is completely through the bottom of B at all times 1 4 2 3 C A C E F D 5 Align extra link G with gear teeth on hardware stem C in the orientation shown below and fasten with safety washer H and screw J 6 A...

Страница 14: ...untersunk side of all taper inserts C should consistently face the same direction on hardware so that screws A are all on the same side 4 Insert screw A and safety washer B into countersunk side of taper insert C and tighten Hold the threaded side of taper insert C firmly while fastening 5 Align new link F joint with ball link E 6 Place new taper insert G halves countersunk side first in the end o...

Страница 15: ... D and the remaining countersunk half of C are aligned inside for a low profile fit in the joint 3 Insert wing lock E and safety washer F into taper lock C half and tighten Hold the taper lock D firmly while fastening 4 Align retainer clip G with tip of wing lock E and press on hard The convex side of the retainer clip must face out Note the retainer clip is very difficult to remove once installed...

Страница 16: ... 2 14W x 5L Premium Pad Without Cover and GT Hardware Shown Gear Tooth Alignment 1 Loosen all hardware adjustment point screws allowing for full articulation of the head support to a desired position Loose screws A around ring B will allow pad orientation adjustment Note Premium BodiLink head support pads are de signed to be used in any orientation including flipped 180º as shown 2 PREMIUM PADS To...

Страница 17: ...s also have lateral positioning features For GT Hardware see page 18 For PT hardware see page 19 Amount of height adjustment available is dependent on the stem length ordered GT Hardware Mid line Positioning Only Mid 6 Lat 6 Mid 8 Lat 8 Max 8 Mid line Positioning Only Lateral Positioning Available Lateral Positioning Available PT Hardware Lateral GT Hardware with Additional Link Shown Max 8 PT Har...

Страница 18: ...ffset D Depth H Height 1 Loosen all hardware adjustment point screws allowing for full articulation of the head support to a desired position 2 Hold hardware and pad in place while tightening each joint Note that adjustments may be affected by each other as gear teeth engage and require compensation from other joints before final tightening ATTENTION It is crucial that gear teeth in all joints are...

Страница 19: ...itioning adjustments A Angle Lateral Offset D Depth H Height Standard Taper Inserts Tool Less Wing Locks not pictured A D D H 1 Loosen all hardware adjustment point screws allowing for full articulation of the head support to a desired position 2 Hold hardware and pad in place while tightening each joint 1 Turn wing lock s counter clockwise to loosen hardware adjustment points allowing for articul...

Страница 20: ...A 2 Slide collar A on hardware stem C to meet the top of mounting bracket B 3 Tighten set screw D in the collar with 2mm hex key until contact is made with the hardware stem This allows for easy positioning of the hardware if it is removed and then replaced Note Collar A is retained in a track in stem C If the collar needs to be removed remove the set screw E located in the track at the bottom of ...

Страница 21: ...y thorough rinse Follow directions on bleach container Let dry completely before use Soiled foams should be replaced Remove cover dab foam with water only cloth and let dry completely before replacing cover Foam should not be exposed to light for any extended period of time Light will cause discoloration of the foam This only effects the appearance of the foam not the functional features There is ...

Страница 22: ...ompany com registration to activate Lifetime Guarantee If manufacturing defects should occur discontinue use immediately Wear from regular use is not considered a manufacturing defect Re placement parts are available by contacting Customer Service or your supplier distributor or retailer Any alterations made to the product or defects caused by irregular use voids the warranty We can only guarantee...

Страница 23: ...23 CLEANING MAINTENANCE THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 24: ...il is a registered trademark of Permobil Inc Quantum is a registered trademark of Pride Mobility Products Corporation GlideWear is a registered trademark of Tamarack Habilitation Technologies Inc Viscool is a registered trademark of American Excelsior Company BLOG Stay connected to related news and updates through these resources www comfortcompany com stay_connected www comfortcompany com UM BODI...

Отзывы: