AUTOMATIC SAFETY FEATURES

During  a  power  outage,  the  stove  will  shut  down
safely.  Do  not  open  the  main  door  or  ash  pan
door. During a power failure, the exhaust fan will
not  run.  Keeping  the  doors  sealed  will  allow  the
exhaust  vent  to  draft  out  naturally.  When  the
power is restored, the stove will not restart. If the
exhaust  temperature  is  still  120  degrees
Fahrenheit  when  power  is  restored,  the  exhaust
and  convection  fans  will  continue  to  run  until  the
stove  cools.  See  lighting  instructions  to  restart
stove.

POWER OUTAGE

OVERHEATING

Over Fire Protection:  If  the  stove  is  being  over
fired or burning too hot, the high limit switches will
automatically  shut  down  the  stove  to  avoid
damage  to  other  components.  If  the  temperature
on  the  hopper  reaches  200  degrees  Fahrenheit,
the auger will automatically stop and the stove will
shut  down.  The  exhaust  fan  will  continue  to  run
until the proof of fire switch cools. Allow the stove
to  cool  before  attempting  to  re-ignite.    See  Start-
Up.

UNDERSTANDING YOUR STOVE

Your stove utilizes a vertical auger fuel feed system
that  is  operated  by  a  microprocessor  controlled
digital circuit board. The digital circuit board allows
the  vertical  auger  fuel  system  to  run  in  a  timer
based,  non-continuous  cycle.  This  cycling  allows
the  auger  to  run  for  a  predetermined  amount  of
time. The auger pushes pellets up a chute located
in  the  hopper.  The  pellets  will  then  turn  and  fall
through another chute into the burn pot. Your stove
is  equipped  with  an  automatic  ignition  system  that
should ignite the fuel within 3-5 minutes of pressing
the  On/Off  button.  As  pellets  fill  the  burn  pot  and
ignite,  outside  air  is  drawn  across  the  fuel  and
heated  during  the  combustion  process  with  is  then
pulled  across  the  heat  exchange  tubes  by  the
exhaust  motor.  As  the  stove  reaches  operating
temperature, the room air is then circulated around
the  heat  exchange  tubes  by  a  room  air  blower,
distributing  warm  air  into  the  room.  The  amount  of
heat that is produced by the stove is proportional to
the  rate  of  fuel  that  is  burned.  Because  a  forced
draft  pressure  is  required  for  the  combustion
process  inside  the  stove,  it  is  extremely  important
that  the  exhaust  system  be  properly  installed  and
maintained.    Also,  the  doors  must  remain  closed
while in operation and the seals on the doors must
be properly maintained.

Install at least one smoke detector on each floor
of your home to ensure your safety. They should
be located away from the stove, and close to the
sleeping areas.
You should have separate CO monitors for areas
near the stove

8

OTHER STOVE FEATURES

Exchange Tube Scraper: Scrapes the carbon
buildup that can accumulate on the heat-transfer
tubes. 

Never touch while stove is Hot.

See Figure A

Glass Air Wash System: Allows the stove to
draw in air, through the lined up slots, to gently
wash against the interior of the glass to help
keep it free of soot buildup. To the right is open,
to the left is closed.  

See Figure B

Figure A: Scraper

Figure B: Glass Airwash

Содержание HP61

Страница 1: ...Operator s Manual HP61 Pellet Stove WWW COMFORTBILT NET...

Страница 2: ...loor Protection Requirements 10 Clearances to Combustibles 11 Stove Venting 12 14 Outside Air Connection 15 Mobile Home Installation 15 Stove Venting Examples 16 21 Controller Operations 22 23 Pre Ope...

Страница 3: ...y occur Glass and other surfaces are hot during operation and cool down Keep children away Carefully supervise children in same room as appliance Do not operate without protective barriers in place Ke...

Страница 4: ...xt Anyone who uses this stove must read the instructions and be familiar with the controls This symbol points out important safety instructions which if not followed could endanger your personal safet...

Страница 5: ...ling the product WARNING CAUTION Tested and approved for pellet fuel Burning any other type of fuel voids warranty 5 WARNING If the electrical power fails at any time when the stove is hot keep all st...

Страница 6: ...AUTION Installation and repair of this pellet stove should be done by a qualified service person The appliance should be inspected before use and at least once per year by a qualified service person I...

Страница 7: ...protected from direct exposure to moisture Water from sources such as condensation and humidity causes pellets to expand and break down into unusable fuel Keep fuel dry It is important to select and u...

Страница 8: ...hen turn and fall through another chute into the burn pot Your stove is equipped with an automatic ignition system that should ignite the fuel within 3 5 minutes of pressing the On Off button As pelle...

Страница 9: ...ING 1 Heat output will vary depending on the brand type and quality of fuel and the moisture content Consult your dealer for best results 2 Based on post 1982 home construction requiring 35 BTU Hr per...

Страница 10: ...ll and use this stove Failure to follow the instructions may result in property damage bodily injury or even death Do not install a flue damper in the exhaust venting system of this unit Do not connec...

Страница 11: ...ation through wall Figure 7 Straight Insallation interior vertical vents Figure 6 Corner Insallation interior vertical vents NOTE When Interior Vent is installed vertically the clearance to the back w...

Страница 12: ...rtical venting height is 18 feet All joints for pellet vent are required to be fastened with at least three screws and all connections including adapters elbows etc should be sealed airtight by inject...

Страница 13: ...ther material Figure 8 Vent Termination A Minimum 48 clearance below or beside any door or window that opens This clearance may be reduced to 18 if using outside air We recommend the door or window be...

Страница 14: ...ust use 4 venting pipe NOTE In order to achieve optimum performance it is recommended that you keep the vent as short as possible especially in regards to the horizontal run The vent must have a suppo...

Страница 15: ...ets are provided All vertical chimney vents must have wall supports All exhaust systems must have a spark arrestor Check with local building officials to see if other codes may apply Structural integr...

Страница 16: ...16 SIMPLE STOVE VENTILATION EXAMPLES...

Страница 17: ...COMPLEX STOVE VENTILATION EXAMPLES INTERIOR VERTICAL INSTALLATION 17...

Страница 18: ...18 CLASS A CHIMNEY RETROFIT...

Страница 19: ...19 MASONRY FIREPLACE HEARTH STOVE...

Страница 20: ...20 ZERO CLEARANCE METAL FIREPLACE HEARTH STOVE...

Страница 21: ...21 FREESTANDING MASONRY CHIMNEY...

Страница 22: ...is pressed again or stove is shut down Scroll up Button Allows you to scroll up to choose items in the menu Exit Button Take you out of current selection and returns to previous option and or screen...

Страница 23: ...ditional Control Mode Displays additional mode info such as holds and overrides 1 2 3 4 5 6 7 Igniter Indicator Indicates when the igniter is being fired 8 Combustion Blower Indicator Indicates when t...

Страница 24: ...al In this mode you can personally adjust and set the heating power level to control the heat level Thermostat Control Temp In this mode you can set the room temperature and the stove will automatical...

Страница 25: ...ou to dictate the level of heat the stove is outputting TEMPERATURE CONTROL MODE The Thermostat Mode allows you to set the temperature of the room The stove will increase or decrease the level of heat...

Страница 26: ...ected the stop time press Enter Next you will have the opportunity to set the desired temperature Use the Scroll Up or Scroll Down keys until you ve reached the appropriate temperature for the times y...

Страница 27: ...y repeating steps 2 5 as desired NOTE You must set your times in chronological order The first schedule slot of one day MUST be earlier in the day than the second schedule slot on your weekly schedule...

Страница 28: ...tage Press Enter again to move into the Set Exhaust Voltage screen See Figure 27 Select the stall or heating power level for the voltage you d like to change by scrolling up or down and pressing Enter...

Страница 29: ...Changing the stall will allow you to test the components in the various heating power levels Fire Tests whether the igniter is working properly Exhaust Tests whether the combustion motor and exhaust...

Страница 30: ...ses Incomplete combustion which occurs during startup and shutdown or incorrect operation of the stove will lead to some soot formation collecting in the exhaust venting system The exhaust venting sys...

Страница 31: ...ible floor or well away from any combustible materials If ashes are disposed of by burial or otherwise dispersed they should remain inside the enclosed container until all cinders have cooled The freq...

Страница 32: ...asket material around the perimeter it will provide a proper seal Using a slender hose attachment on your ash vac thoroughly vacuum out these chambers top to bottom These chambers extend all the way u...

Страница 33: ...d SMG will at their discretion furnish parts and labor to correct any defect caust by the faulty material or workmanship For other warranty repairs please read the One Year Warranty listed below ONE Y...

Страница 34: ...Chassis and Paneling may vary by model...

Страница 35: ......

Отзывы: