background image

OPERATION

After  you  have  chosen  the  desired  operation
mode for your stove, press the ON/OFF button 
to start the stove ignite cycle.

25

START-UP

When  the  stove  turns  on,  the  ignition  indicator
and the combustion blower indicator will appear
on the screen 

(#7 & 8 in Figure 19) 

 "Ignite"  will

also appear in the work stage box on the screen.
After  approximately  four  seconds,  the  vacuum
switch  indicator  will  appear.  Also  note  that  the
hopper lid open indicator "L" will appear anytime
the hopper lid is properly shut and sealed.
The  auger  indicator  will  flash  on  the  screen,
indicating that the auger is feeding pellets. Within
5-8 minutes, a fire should ignite. Once the fire is
lit, 

and 

the 

stove 

achieves 

operating

temperature,  the  work  stage  box  on  the  screen
will read "Heating", and the room blower fan will
engage.

WORKING IN THE DIFFERENT
OPERATION MODES

MANUAL MODE

The manual mode is the default mode setting if
no  other  mode  is  chosen  before  the  stove  is
turned  on.  In  the  manual  mode,  you  have  the
ability  to  change  the  heat  levels,  which  will
increase or decrease the amount of heat that the
stove puts out.
To change the power level in manual mode, use
the  "Scroll  Up"  or  "Scroll  Down"  buttons  on  the
control  pad. 

(See  #'s  8  and  10  on  Figure  17).

Pressing either of these buttons once will move
the power level up or down one level.

NOTE: This mode does not allow you to directly
adjust  specific  temperatures.  The  manual  mode
simply allows you to dictate the level of heat the
stove is outputting.

TEMPERATURE CONTROL MODE

The  Thermostat  Mode  allows  you  to  set  the
temperature of the room. The stove will increase or
decrease  the  level  of  heat  it  outputs  automatically
to  keep  the  room  at  the  set  temperature.  To
increase or decrease the "Call to" temperature, use
the "Scroll Up" or "Scroll Down" button. The current
room  temperature  will  be  displayed  in  the
temperature display box on the screen, as will the
"Call to" temperature. 
If  the  room  temperature  falls  below  the  "call  to"
temperature, the stove's heat power level indicator
will automatically rise to five. When the temperature
has  been  reached,  and  maintained  for  about  a
minute, the heat power level will return to one and it
will stay there until more heat is needed.

NOTE:  In  thermostat  mode,  the  stove  will  not  shut
off or go into standby. It will simply idle and continue
to  produce  a  fire  until  the  room  temperature  falls
below  the  "call  to"  temperature.  When  idling,  the
heat power level will read at level one in the power
level box on the display screen. 

WEEKLY MODE

The  Weekly  Mode  allows  a  user  to  control  and
schedule  the  stove  operation  during  set  times  and
days  throughout  the  week.  You  can  select  four
different operation times for each of the seven days
of the week.

IMPORTANT:    Remember  to  set  your  weekly
schedule  in  Weekly  Mode  before  igniting  a  fire.  If
you  attempt  to  set  a  weekly  schedule  while  the
stove  is  running  in  Manual  or  Temp  modes,  the
weekly  schedule  will  not  set,  and  the  screen  will
prompt you to wait until you have turned the stove
off  and  it  has  cooled  down  before  allowing  you  to
retry.

Содержание HP61

Страница 1: ...Operator s Manual HP61 Pellet Stove WWW COMFORTBILT NET...

Страница 2: ...loor Protection Requirements 10 Clearances to Combustibles 11 Stove Venting 12 14 Outside Air Connection 15 Mobile Home Installation 15 Stove Venting Examples 16 21 Controller Operations 22 23 Pre Ope...

Страница 3: ...y occur Glass and other surfaces are hot during operation and cool down Keep children away Carefully supervise children in same room as appliance Do not operate without protective barriers in place Ke...

Страница 4: ...xt Anyone who uses this stove must read the instructions and be familiar with the controls This symbol points out important safety instructions which if not followed could endanger your personal safet...

Страница 5: ...ling the product WARNING CAUTION Tested and approved for pellet fuel Burning any other type of fuel voids warranty 5 WARNING If the electrical power fails at any time when the stove is hot keep all st...

Страница 6: ...AUTION Installation and repair of this pellet stove should be done by a qualified service person The appliance should be inspected before use and at least once per year by a qualified service person I...

Страница 7: ...protected from direct exposure to moisture Water from sources such as condensation and humidity causes pellets to expand and break down into unusable fuel Keep fuel dry It is important to select and u...

Страница 8: ...hen turn and fall through another chute into the burn pot Your stove is equipped with an automatic ignition system that should ignite the fuel within 3 5 minutes of pressing the On Off button As pelle...

Страница 9: ...ING 1 Heat output will vary depending on the brand type and quality of fuel and the moisture content Consult your dealer for best results 2 Based on post 1982 home construction requiring 35 BTU Hr per...

Страница 10: ...ll and use this stove Failure to follow the instructions may result in property damage bodily injury or even death Do not install a flue damper in the exhaust venting system of this unit Do not connec...

Страница 11: ...ation through wall Figure 7 Straight Insallation interior vertical vents Figure 6 Corner Insallation interior vertical vents NOTE When Interior Vent is installed vertically the clearance to the back w...

Страница 12: ...rtical venting height is 18 feet All joints for pellet vent are required to be fastened with at least three screws and all connections including adapters elbows etc should be sealed airtight by inject...

Страница 13: ...ther material Figure 8 Vent Termination A Minimum 48 clearance below or beside any door or window that opens This clearance may be reduced to 18 if using outside air We recommend the door or window be...

Страница 14: ...ust use 4 venting pipe NOTE In order to achieve optimum performance it is recommended that you keep the vent as short as possible especially in regards to the horizontal run The vent must have a suppo...

Страница 15: ...ets are provided All vertical chimney vents must have wall supports All exhaust systems must have a spark arrestor Check with local building officials to see if other codes may apply Structural integr...

Страница 16: ...16 SIMPLE STOVE VENTILATION EXAMPLES...

Страница 17: ...COMPLEX STOVE VENTILATION EXAMPLES INTERIOR VERTICAL INSTALLATION 17...

Страница 18: ...18 CLASS A CHIMNEY RETROFIT...

Страница 19: ...19 MASONRY FIREPLACE HEARTH STOVE...

Страница 20: ...20 ZERO CLEARANCE METAL FIREPLACE HEARTH STOVE...

Страница 21: ...21 FREESTANDING MASONRY CHIMNEY...

Страница 22: ...is pressed again or stove is shut down Scroll up Button Allows you to scroll up to choose items in the menu Exit Button Take you out of current selection and returns to previous option and or screen...

Страница 23: ...ditional Control Mode Displays additional mode info such as holds and overrides 1 2 3 4 5 6 7 Igniter Indicator Indicates when the igniter is being fired 8 Combustion Blower Indicator Indicates when t...

Страница 24: ...al In this mode you can personally adjust and set the heating power level to control the heat level Thermostat Control Temp In this mode you can set the room temperature and the stove will automatical...

Страница 25: ...ou to dictate the level of heat the stove is outputting TEMPERATURE CONTROL MODE The Thermostat Mode allows you to set the temperature of the room The stove will increase or decrease the level of heat...

Страница 26: ...ected the stop time press Enter Next you will have the opportunity to set the desired temperature Use the Scroll Up or Scroll Down keys until you ve reached the appropriate temperature for the times y...

Страница 27: ...y repeating steps 2 5 as desired NOTE You must set your times in chronological order The first schedule slot of one day MUST be earlier in the day than the second schedule slot on your weekly schedule...

Страница 28: ...tage Press Enter again to move into the Set Exhaust Voltage screen See Figure 27 Select the stall or heating power level for the voltage you d like to change by scrolling up or down and pressing Enter...

Страница 29: ...Changing the stall will allow you to test the components in the various heating power levels Fire Tests whether the igniter is working properly Exhaust Tests whether the combustion motor and exhaust...

Страница 30: ...ses Incomplete combustion which occurs during startup and shutdown or incorrect operation of the stove will lead to some soot formation collecting in the exhaust venting system The exhaust venting sys...

Страница 31: ...ible floor or well away from any combustible materials If ashes are disposed of by burial or otherwise dispersed they should remain inside the enclosed container until all cinders have cooled The freq...

Страница 32: ...asket material around the perimeter it will provide a proper seal Using a slender hose attachment on your ash vac thoroughly vacuum out these chambers top to bottom These chambers extend all the way u...

Страница 33: ...d SMG will at their discretion furnish parts and labor to correct any defect caust by the faulty material or workmanship For other warranty repairs please read the One Year Warranty listed below ONE Y...

Страница 34: ...Chassis and Paneling may vary by model...

Страница 35: ......

Отзывы: