INSTALLATION

 

It is recommended the stove be installed and serviced by

 

authorized professionals.

 

Proper  installation  of  this  stove  is  necessary  for  safe  and 

efficient  operation.  Installing  this  product  improperly  may 

result in a house fire and personal injury. All applicable building 

codes  for  your  location  must  be  followed.  In  areas  where 

building codes require additional steps to the installation of this 

product  not  included  in  this  manual,  the  building  codes  will 

take  precedent  and  must  be  followed.  Contact  your  local 

building  inspector  to  obtain  any  necessary  permits  or 

inspection guidelines before installing the product.

 

STOV

E PLA

CEMENT

 

Sketch out a plan for installing the stove including dimensions 

before  permanent  placement.  When  determining  the  location 

for  the  stove,  wall  stud  location  is  critical.  You  may  need  to 

adjust the location of the stove to avoid trying to vent through a 

wall stud. Before placing the pellet stove, connect the vent and 

allow for minimum clearance to combustible walls. 

FLOOR PROTECTION REQUIREMENTS 

The  stove must be installed on a noncombustible floor, 

with proper floor protection, or on a masonry hearth. 

When a clean out t-vent is installed in the inside of a 

home, the floor protector   

must extend 2 beyond rear of t-vent. 

SEE

 

FIGUR

E 1

 .   

When stove   

SEE FIGURE 1 When stove is vented straight through 

the wall and the clean out t-vent is on the exterior of 

the home, the minimum clearance is 2 from the back 

of  the  stove  to    the  wall. 

SEE 

FIGUR

2

.  The 

minimum  floor  protector  material  is  24  GA  sheet 

metal 

Figures 1

        Figures 2 

Figures 1 and 2:    Pellet stove floor pad clearances 

WARNING 

RE

AD 

THIS

 

ENTIRE

 

MANUAL

 

BEFORE

 

Y

OU 

INSTALL

 

AND

 

USE

 

THIS

 

STOVE.

 

FAILURE

  TO 

FOLL

OW 

THE

 

IN-

 

STRUCTIONS

 

M

AY 

RESULT

 

I

PROPERTY

 

DAMAGE,

 

BODILY

 

INJURY,

 

OR

 

EVE

DEATH.

   

DO  NOT 

INSTALL

 

A

 

FLUE

 

DAMPER

 

IN

 

THE

 

EXHAUST

 

VENTING

 

SYSTEM

 

OF

 

THIS

 

UNIT.

   

DO  NOT 

CONNE

CT 

THIS

 

U

NIT  TO  A 

CHIMNEY

 

FLUE

 

SERVING

 

ANOTHER

 

APPLIANCE.

 

 

CHILDRE

AND

 

ADULTS

 

SH

OULD BE 

ALERTED

 TO 

THE

 

HAZARDS

 

OF

 

HIGH

 

SURFACE

 

TEMPERATURES

 

AND

 

SHOUL

S

TAY  AWAY  TO 

AVOI

BUMPS

  TO 

SKI

AND/

 

OR

 

CLOTHING.

   

YOUNG

 

CHILDREN

 

SHOULD

 

BE

 

CAREFULLY

 

SUPER-

 

VISE

WHE

THEY

 

ARE

 

I

THE

 

SAME

 

ROOM

 

AS

 

THE

 

STOVE.

 

CLOTHING

 

AND

 

OTHER

 

FLAMMABLE

 

MATERIALS

 

SHOULD

 

NOT

 

BE

 

PLACED

 

ON

 

OR

 

NEAR

 

THIS

 

UNIT.

 

CAUTION 

THIS STOVE SHOULD NOT BE USED AS THE ONLY SOURCE 

OF HEAT IN THE HOUSE. POWER OUTAGES AND PERIODIC 

MAINTENANCE WILL RESULT IN A TOTAL LOSS OF HEAT. 
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT 

RESTRICTIONS AND INSTALLATION INSPECTION 

REQUIREMENTS IN YOUR AREA. 
CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL 

BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE 

PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED 

FOR A PERMIT. 
KEEP COMBUSTIBLE MATERIALS (SUCH AS GRASS, 
LEAVES, ETC.) AT LEAST 3 FEET AWAY FROM THE FLUE 
OUTLET ON THE OUTSIDE OF THE BUILDING. 
INSTALLATION AND REPAIR OF THIS 
PELLETSTOVE SHOULD BE DONE BY A QUALIFIED SERVICE 
PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE 
PERSON. IT IS IMPERATIVE THAT CONTROL 
COMPARTMENTS, FIRE BOX, AND CIRCULATING AIR 
PASSAGEWAYS OF THE STOVE BE KEPT CLEAN. 

 

 

 

 

 

 

 

 

Содержание HP55

Страница 1: ...O NOT DISCARD IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS INCLUDED SAVE THESE INSTRUCTIONS AND LEAVE THIS MANUAL WITH ANY PARTY RESPONSIBLE FOR USE AND OPERATION I M P O R T A N CAUTION CONTACT L...

Страница 2: ...RE HOT DURING OPERATION AND COOL DOWN KEEP CHILDREN AWAY CAREFULLY SUPERVISE CHILDREN IN SAME ROOM AS APPLIANCE DO NOT OPERATE WITH PROTECTIVE BARRIERS OPEN OR REMOVED KEEP CLOTHING FURNITURE DRAPERIE...

Страница 3: ...uses this stove must read the instructions and be familiar with the controls This symbol points out important safety instructions which if not followed could endanger your personal safety Read and fol...

Страница 4: ...230 volt power source is required DO NOT install a flue damper in the exhaust venting system of this unit DO NOT connect this unit to a chimney flue servicing another appliance DO NOT install in a sle...

Страница 5: ...pen while unattended CAUTION INSTALLATION AND REPAIR OF THIS PELLET STOVE SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ONCE A YEAR BY A QUALIF...

Страница 6: ...ombustibles 10 VENTING 11 Type of Vent 11 Pellet Vent Installation 11 Vent Termination Clearances 12 13 Outside Air Connection 14 Mobile Home 14 Venting Installation Examples 15 20 BECOMING FAMILIAR W...

Страница 7: ...ing these materials does not prohibit the use of fire starters made from paper cardboard saw dust wax and similar substances for the purpose of starting a fire in an affected wood heater Burning these...

Страница 8: ...is an serious clinker in the burnpot 2 If there are some leakages on the stove for example the glass door 3 The exhaust channel have been blocked partially The input voltage is abnormal SPECIFICATION...

Страница 9: ...earance is 2 from the back of the stove to the wall SEE FIGURE 2 The minimum floor protector material is 24 GA sheet metal Figures 1 Figures 2 Figures 1 and 2 Pellet stove floor pad clearances WARNING...

Страница 10: ...are minimum clearances to combustible walls NOTE When interior vent is installed vertically the clearance to the back wall is determined by the vent size used Install vent at clearance specified by th...

Страница 11: ...tem Total length of horizontal vent must not exceed 10 feet The maximum recommended vertical venting height is 18 feet All joints for pellet vent are required to be fastened with at least three screws...

Страница 12: ...me plugged by snow or other material Figure 7 Vent Termination A A Minimum4 clearance below or beside any door or window that opens This clearance may be reduced to18 if using out side air We recommen...

Страница 13: ...s you must use 4 venting pipes NOTE In order to achieve optimum performance it is recommended that you keep the vent as short as possible especially in regards to the horizontal run The vent must have...

Страница 14: ...llation instructions the following requirements are mandatory for installation in a mobile home 1 The stove must be permanently attached to the floor 2 Stove must have an outside air source 3 Stove mu...

Страница 15: ...Operator s Manual HP55 Pellet Stove 15 SIMPLE STOVE VENTILATION EXAMPLES...

Страница 16: ...Operator s Manual HP55 Pellet Stove 16 COMPLEX STOVE VENTILATION EXAMPLES INTERIOR VERTICAL INSTALLATION Figure 12 Interior Vertical Installation...

Страница 17: ...Operator s Manual HP55 Pellet Stove 17 CLASS A CHIMNEY RETROFIT Figure 13 Class A Chimney Retrofit...

Страница 18: ...Operator s Manual HP55 Pellet Stove 18 MASONRY FIREPLACE HEARTH STOVE Figure 14 Masonry Fireplace Hearth Stove...

Страница 19: ...Operator s Manual HP55 Pellet Stove 19 ZERO CLEARANCE METAL FIREPLACE HEARTH STOVE Figure 15 Zero Clearance Metal Fireplace Hearth Stove...

Страница 20: ...Operator s Manual HP55 Pellet Stove 20 FREESTANDING MASONRY CHIMNEY Figure 16 Freestanding Masonry Chimney...

Страница 21: ...complete an operation See the combination key function list below Key 6 Timer use scroll up and down to change value Key 11 Feeding Used for newly installed stoves to prime the auger Key 9 Stop Feedin...

Страница 22: ...e 5 Current Temperature Displays the temperature that is being read by the temp sensing wire Figure 18 Display Screen 6 Current Time Period In weekly mode this displays the current time setting 7 Day...

Страница 23: ...rm to the auger feed system SEE FIGURE 21 Also take care in making sure there is no pellet material in the hopper lid seating surfaces Close the lid This stove has a safety switch that will not allow...

Страница 24: ...is pushing out TEMPERATURE CONTROL MODE The Temperature Mode allows you to set the temperature of the room The stove will increase or decrease the level of heat it puts out automatically to keep the r...

Страница 25: ...WEEKLY Select Set Weekly Press ENTER This will take you into the Weekly Schedule screen Figure 25 Weekly MON ALL 1 NO 2 NO 3 NO 4 NO Figure 25 1 In the Weekly Schedule screen you can begin with selec...

Страница 26: ...n change to the level need to set Press again to exit highlight Note The level item has 8 options IG01 IG02 IG03 correspond to ignition stage H01 H02 H03 H04 H05 correspond to Heating stage 2 Move to...

Страница 27: ...he period between two lasting time is the Span Time It can be adjust from 30min to 60 min Smart Ash cleaning is an automatic Ash cleaning cycle It has 3 setting light medium heavy Set ECO Select the E...

Страница 28: ...ss these two components of your stove to see if they are properly working Note The option is just for serviceman Information Select the Information and press enter This will take you into the informat...

Страница 29: ...the control pad to initiate the shut down mode The On Off indicator on the screen will read OFF The auger will stop feeding pellets but the room air distribution blower and exhaust fan will continue...

Страница 30: ...ipe the glass clean with a dry or damp rag If this does not clean the glass use any non abrasive cleaner Using ceramic stove top cleaner can be helpful in removing soot from the glass Inspect gaskets...

Страница 31: ...gged venting will effect the quality of the fire Make sure to clean any screens in the venting regularly A plugged screen will shut of combustion air and cause the fire to die or burn poorly DAILY MAI...

Страница 32: ...burned IMPORTANT NOTE A HOLE CAN BE CUT IN THE GASKET USING A UTILITY KNIFE TO ACCESS THE housing THIS WILL ALLOW YOU TO REUSE THE GASKET Annually OR EVERY 3 4 TONS OF FUEL Remove and clean the exhaus...

Страница 33: ...NOT OPERATE UNIT WITH PANELS REMOVED OR OPEN HOT PARTS DO NOT OPERATE THE UNIT WITH PANEL OPEN RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT IN THE EVENT OF COMPONENT FAILURE REPLACE...

Страница 34: ...control Main door or ash pan not sealed No negative pressure in fire chamber Piping or stove may be plugged with ash The pressure sensor shuts off the feed auger when there is no negative pressure in...

Страница 35: ...safety switch if not operating properly PROBLEM CAUSE SOLUTION Fire burns lazy and smoky Stove is dirty Poor quality fuel Clean fire pot Clean ash pan Clean exhaust vent system Clean stove through cov...

Страница 36: ...ited to blowers wiring vacuum switches speed controls control boxes switches pilot assemblies thermostats and igniters are covered under SMG Hearth and Home LLC s one year warranty Our firepots and la...

Отзывы: