Operator’s Manual

 

HP55 Pellet Stove

~  29  ~

 

SET

 

Blower

Select

 

th

“set

 

Blower”,

 

and

 

press

 

enter.

 

This will take you 

into the “Set Blower” screen. 

SEE

 

FIGURE

 

36.

 

Set Blower 

Blower :ON 

Figure 36 

You can set Blower off only when the pellet stove   

have dual convection constructions: natural convection 

and Blower convection. 

RESET

Select

 

th

“Reset”,

 

and

 

press

 

enter.

 

This will take you into the 

“Reset” screen. 

SEE

 

FIGURE

 

37.

Figure 37

 

If at any time you desire to return your controlled stove settings 
to their original state, (i.e. rest blower voltage levels or weekly 
schedules) your stove does have the ability to restore the 
default settings.   

 

SHUT

 D

O

WN P

ROCEDURE

Press  the   

button  on  the  control  pad  to  initiate  the 

shut  down  mode. 

  The  On/Off  indicator  on  the  screen  will 

read OFF.    The auger will stop feeding pellets, but the room air 

distribution  blower  and  exhaust  fan  will  continue  to  operate. 

Once the stove has cooled down, the screen light will turn off.     

Ala

rm Mess

ages

All alarm messages are showed as below. (figure 38). 

Display at the 
stove 

Action to be taken 

Lost connect 

Check if the plug of data cable is 
loose 

Ignite failure 

1.Check if Pellet fall into
burnpot
2.check if ignitor work properly
3.check if exhaust fan stop or
door is not close

Low Temperature 

Check if Hopper is empty 

High Temperature  Check if feeding is abnormal 

Figure 38

 

Reset 

Are you sure to reset? yes 

WARNING

 

NEVER

 

SHUT

 

THE

 

STOVE

 

DO

WN BY 

UNPLUGGING

 

I

FROM

 

THE

 

POWER

 

SOURCE.

NEVER

 

SHUT

 

THE

 

STOVE

 

DO

WN BY 

SWITCHING

 

OFF

 

THE

 

M

AIN 

POWER

 

SWIT

CH ON 

THE

 

REAR

 

OF

 

THE

 

STOVE.

 

Содержание HP55

Страница 1: ...O NOT DISCARD IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS INCLUDED SAVE THESE INSTRUCTIONS AND LEAVE THIS MANUAL WITH ANY PARTY RESPONSIBLE FOR USE AND OPERATION I M P O R T A N CAUTION CONTACT L...

Страница 2: ...RE HOT DURING OPERATION AND COOL DOWN KEEP CHILDREN AWAY CAREFULLY SUPERVISE CHILDREN IN SAME ROOM AS APPLIANCE DO NOT OPERATE WITH PROTECTIVE BARRIERS OPEN OR REMOVED KEEP CLOTHING FURNITURE DRAPERIE...

Страница 3: ...uses this stove must read the instructions and be familiar with the controls This symbol points out important safety instructions which if not followed could endanger your personal safety Read and fol...

Страница 4: ...230 volt power source is required DO NOT install a flue damper in the exhaust venting system of this unit DO NOT connect this unit to a chimney flue servicing another appliance DO NOT install in a sle...

Страница 5: ...pen while unattended CAUTION INSTALLATION AND REPAIR OF THIS PELLET STOVE SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ONCE A YEAR BY A QUALIF...

Страница 6: ...ombustibles 10 VENTING 11 Type of Vent 11 Pellet Vent Installation 11 Vent Termination Clearances 12 13 Outside Air Connection 14 Mobile Home 14 Venting Installation Examples 15 20 BECOMING FAMILIAR W...

Страница 7: ...ing these materials does not prohibit the use of fire starters made from paper cardboard saw dust wax and similar substances for the purpose of starting a fire in an affected wood heater Burning these...

Страница 8: ...is an serious clinker in the burnpot 2 If there are some leakages on the stove for example the glass door 3 The exhaust channel have been blocked partially The input voltage is abnormal SPECIFICATION...

Страница 9: ...earance is 2 from the back of the stove to the wall SEE FIGURE 2 The minimum floor protector material is 24 GA sheet metal Figures 1 Figures 2 Figures 1 and 2 Pellet stove floor pad clearances WARNING...

Страница 10: ...are minimum clearances to combustible walls NOTE When interior vent is installed vertically the clearance to the back wall is determined by the vent size used Install vent at clearance specified by th...

Страница 11: ...tem Total length of horizontal vent must not exceed 10 feet The maximum recommended vertical venting height is 18 feet All joints for pellet vent are required to be fastened with at least three screws...

Страница 12: ...me plugged by snow or other material Figure 7 Vent Termination A A Minimum4 clearance below or beside any door or window that opens This clearance may be reduced to18 if using out side air We recommen...

Страница 13: ...s you must use 4 venting pipes NOTE In order to achieve optimum performance it is recommended that you keep the vent as short as possible especially in regards to the horizontal run The vent must have...

Страница 14: ...llation instructions the following requirements are mandatory for installation in a mobile home 1 The stove must be permanently attached to the floor 2 Stove must have an outside air source 3 Stove mu...

Страница 15: ...Operator s Manual HP55 Pellet Stove 15 SIMPLE STOVE VENTILATION EXAMPLES...

Страница 16: ...Operator s Manual HP55 Pellet Stove 16 COMPLEX STOVE VENTILATION EXAMPLES INTERIOR VERTICAL INSTALLATION Figure 12 Interior Vertical Installation...

Страница 17: ...Operator s Manual HP55 Pellet Stove 17 CLASS A CHIMNEY RETROFIT Figure 13 Class A Chimney Retrofit...

Страница 18: ...Operator s Manual HP55 Pellet Stove 18 MASONRY FIREPLACE HEARTH STOVE Figure 14 Masonry Fireplace Hearth Stove...

Страница 19: ...Operator s Manual HP55 Pellet Stove 19 ZERO CLEARANCE METAL FIREPLACE HEARTH STOVE Figure 15 Zero Clearance Metal Fireplace Hearth Stove...

Страница 20: ...Operator s Manual HP55 Pellet Stove 20 FREESTANDING MASONRY CHIMNEY Figure 16 Freestanding Masonry Chimney...

Страница 21: ...complete an operation See the combination key function list below Key 6 Timer use scroll up and down to change value Key 11 Feeding Used for newly installed stoves to prime the auger Key 9 Stop Feedin...

Страница 22: ...e 5 Current Temperature Displays the temperature that is being read by the temp sensing wire Figure 18 Display Screen 6 Current Time Period In weekly mode this displays the current time setting 7 Day...

Страница 23: ...rm to the auger feed system SEE FIGURE 21 Also take care in making sure there is no pellet material in the hopper lid seating surfaces Close the lid This stove has a safety switch that will not allow...

Страница 24: ...is pushing out TEMPERATURE CONTROL MODE The Temperature Mode allows you to set the temperature of the room The stove will increase or decrease the level of heat it puts out automatically to keep the r...

Страница 25: ...WEEKLY Select Set Weekly Press ENTER This will take you into the Weekly Schedule screen Figure 25 Weekly MON ALL 1 NO 2 NO 3 NO 4 NO Figure 25 1 In the Weekly Schedule screen you can begin with selec...

Страница 26: ...n change to the level need to set Press again to exit highlight Note The level item has 8 options IG01 IG02 IG03 correspond to ignition stage H01 H02 H03 H04 H05 correspond to Heating stage 2 Move to...

Страница 27: ...he period between two lasting time is the Span Time It can be adjust from 30min to 60 min Smart Ash cleaning is an automatic Ash cleaning cycle It has 3 setting light medium heavy Set ECO Select the E...

Страница 28: ...ss these two components of your stove to see if they are properly working Note The option is just for serviceman Information Select the Information and press enter This will take you into the informat...

Страница 29: ...the control pad to initiate the shut down mode The On Off indicator on the screen will read OFF The auger will stop feeding pellets but the room air distribution blower and exhaust fan will continue...

Страница 30: ...ipe the glass clean with a dry or damp rag If this does not clean the glass use any non abrasive cleaner Using ceramic stove top cleaner can be helpful in removing soot from the glass Inspect gaskets...

Страница 31: ...gged venting will effect the quality of the fire Make sure to clean any screens in the venting regularly A plugged screen will shut of combustion air and cause the fire to die or burn poorly DAILY MAI...

Страница 32: ...burned IMPORTANT NOTE A HOLE CAN BE CUT IN THE GASKET USING A UTILITY KNIFE TO ACCESS THE housing THIS WILL ALLOW YOU TO REUSE THE GASKET Annually OR EVERY 3 4 TONS OF FUEL Remove and clean the exhaus...

Страница 33: ...NOT OPERATE UNIT WITH PANELS REMOVED OR OPEN HOT PARTS DO NOT OPERATE THE UNIT WITH PANEL OPEN RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT IN THE EVENT OF COMPONENT FAILURE REPLACE...

Страница 34: ...control Main door or ash pan not sealed No negative pressure in fire chamber Piping or stove may be plugged with ash The pressure sensor shuts off the feed auger when there is no negative pressure in...

Страница 35: ...safety switch if not operating properly PROBLEM CAUSE SOLUTION Fire burns lazy and smoky Stove is dirty Poor quality fuel Clean fire pot Clean ash pan Clean exhaust vent system Clean stove through cov...

Страница 36: ...ited to blowers wiring vacuum switches speed controls control boxes switches pilot assemblies thermostats and igniters are covered under SMG Hearth and Home LLC s one year warranty Our firepots and la...

Отзывы: