Comfort Bilt HP22 Скачать руководство пользователя страница 32

Operator’s Manual                                                                                                             

HP22 Pellet Stove

 

~ 32 ~

 

 

TROUBLESHOOTING & REPAIR 

We build quality and durability into the design of our products; 
but no amount of careful design by us, and careful 
maintenance by you, can guarantee a repair-free life for your   
stove. Most repairs will be minor, and easily fixed by following 
the suggestions in the troubleshooting guide in this section. 
The  guide  will  help  you  pinpoint  the  causes  of  common 
problems and identify remedies. 
For more complicated repairs, you may want  to rely on your 
retailer. A parts catalog is included in this section. 

We will always be glad to answer any questions you have, or 
help you  find  suitable assistance. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  WARNING 

WHEN PERFORMING ANY INTERNAL 
MAINTENANCE.   

 

    MOVING PARTS INSIDE OF THE CABINET 

MAY CAUSE

 INJURY. DO NOT OPERATE UNIT WITH 

PANELS REMOVED OR OPEN.   

 

  HOT PARTS. DO NOT OPERATE THE UNIT 

WITH

 PANEL OPEN.   

 

  RISK OF ELECTRIC SHOCK. DISCONNECT 

POWER

 BEFORE SERVICING UNIT. 

 

 

IN THE EVENT OF COMPONENT FAILURE, 

REPLACE

 WITH THE ORIGINAL FACTORY EQUIPMENT 

 

CAUTION 

THIS IS A MINIMUM REQUIREMENT FOR SOOT 
AND 

FLY ASH REMOVAL. ASHES SHOULD BE PLACED IN A 

METAL  CONTAINER  WITH  A  TIGHT  FITTING  LID.  THE 
CONTAINER 

SHOULD 

BE 

PLACED 

ON 

NON-COMBUSTIBLE 

FLOOR, 

WELL 

AWAY 

FROM 

COMBUSTIBLE  MATERIALS,  PENDING  FINAL  DISPOSAL.  IF 
ASHES  ARE  DISPOSED  OF  BY  BURIAL  IN  SOIL  OR 
OTHERWISE  LOCALLY  DISPERSED,  THEY  SHOULD  BE 
RETAINED  IN  THE  CLOSED  CONTAINER  UNTIL  ALL 
CINDERS ARE NO THOROUGHLY COOL

 

    CAUTION 

DO  NOT  OPERATE  STOVE  WITH  BROKEN 
GLASS.   

DO NOT SLAM THE DOOR SHUT.   
DO NOT STRIKE GLASS.   
DO NOT USE ABRASIVE CLEANERS.   
DO NOT CLEAN HOT GLASS. 
REPLACE  CERAMIC  GLASS  WITH  FACTORY 
AUTHORIZED REPLACEMENT PARTS ONLY.   
THE  CLINKER  WILL  REMAIN  HOT  FOR  SEVERAL 
MINUTES AFTER IT IS PULLED OUT OF THE FIRE POT 

Содержание HP22

Страница 1: ...OR EVEN DEATH CAUTION DO NOT DISCARD IMPORTANT OPERATING AND AINTENANCE INSTRUCTIONS INCLUDED SAVE THESE INSTRUCTIONS AND LEAVE THIS MANUAL WITH ANY PARTY RESPONSIBLE FOR USE AND OPERATION I M P O R T...

Страница 2: ...NG AND MAINTENANCE IN STRUCTIONS INCLUDED READ UNDERSTAND AND FOLLOW THESE IN STRUCTIONS FOR SAFE INSTALLATION AND OP ERATION LEAVE THIS MANUAL WITH PARTY RESPONSIBLE FOR USE AND OPERATION CAUTION CHE...

Страница 3: ...uses this stove must read the instructions and be familiar with the controls This symbol points out important safety instructions which if not followed could endanger your personal safety Read and fo...

Страница 4: ...arranty DO NOT route power cord in high traffic areas A power surge protector plugged into a grounded 230 volt power source is required DO NOT install a flue damper in the exhaust venting system of th...

Страница 5: ...en while unattended CAUTION INSTALLATION AND REPAIR OF THIS PELLET STOVE SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ONCE A YEAR BY A QUALIFI...

Страница 6: ...ion Clearances 12 13 Outside Air Connection 14 Mobile Home 14 Venting Installation Examples 15 20 BECOMING FAMILIAR WITH YOU CONTROLLER 21 22 Controller Buttons 21 Screen Display 22 PRE OPERATION 23 O...

Страница 7: ...nce of the unit and will void the warranty The Pellet Fuel Institute PFI has established standards for wood pellet manufacturers Only use pellets that meet or exceed PFI standards for premium fuels CL...

Страница 8: ...sture content Consult your dealer for best results 2 Based on post 1982home construction requiring 35 BTU Hr per Sq Ft GLASS SPECIFICATIONS This stove is equipped with ceramic glass Replace glass only...

Страница 9: ...learance is 2 from the back of the stove to the wall SEE FIGURE 2 The minimum floor protector material is 24 GA sheet metal Figures 1 Figures 2 Figures 1 and 2 Pellet stove floor pad clearances WARNIN...

Страница 10: ...ation through the wall vents Figure 5 Straight installation interior vertical vents Figure 6 Corner installation interior vertical vents NOTE When interior vent is installed vertically the clearance t...

Страница 11: ...nuisance or hazard from exposure to high temperatures The installation must include a clean out tee to enable collection of fly ash andto permit periodic cleaning of the exhaust system Total length of...

Страница 12: ...must not be located where it will become plugged by snow or other material A A Minimum 4 clearance below or beside any door or window that opens This clearance may be reduced to 18 if using out side...

Страница 13: ...performance it is recommended that you keep the vent as short as possible especially in regards to the horizontal run The vent must have a support bracket every 5 of pellet vent when on the exterior o...

Страница 14: ...INSTALL IN A SLEEPING ROOM CAUTION THE OPERATION OF EXHAUST FANS SUCH AS BATHROOM FANS ATTIC FANS ETC MIGHT STARVE THE PELLET STOVE OF COMBUSTIBLE AIR CREATING A NEGATIVE PRESSURE IN THE ROOM PROVIDE...

Страница 15: ...Operator s Manual HP22 Pellet Stove 15...

Страница 16: ...Operator s Manual HP22 Pellet Stove 16...

Страница 17: ...Operator s Manual HP22 Pellet Stove 17...

Страница 18: ...Operator s Manual HP22 Pellet Stove 18...

Страница 19: ...Operator s Manual HP22 Pellet Stove 19...

Страница 20: ...Operator s Manual HP22 Pellet Stove 20...

Страница 21: ...n weekly mode after raising the Call To temperature will maintain that temperature until the button is pressed again or the stove is shut down 8 Scroll Up Button Allows you to scroll up to choose item...

Страница 22: ...g room 6 Additional Control Mode 7 Ignitor Indicator Indicates ignition cycle burning cycle is currently happening 8 Combustion Blower Indicator Indicates combustion blower is running 9 Auger Indicato...

Страница 23: ...ore actually starting your Stove you will need to determine in which mode you would like to run the stove This stove can operate in three modes 1 Manual Under thismode you can personally adjust and se...

Страница 24: ...room at the set temperature To increase or decrease the call to temperature use the SCROLL UP or SCROLL DOWN button The current room temperature will be displayed in the temperature display box on the...

Страница 25: ...Next Pressing Figure 23 ENTER again will take you to the following day Proceed with setting a schedule for the rest of the week using the preceding instructions NOTE Along with the Next option on the...

Страница 26: ...t without blowing cold air Increasing the blower voltage causes the convection motor to run faster extracting more heat from the unit NOTE If having issues with the stove overtemping in any setting in...

Страница 27: ...t will also assist in burning lower quality fuels that may otherwise cause unwanted buildup NOTE Be sure to visually watch the burn rate if the combustion voltage is decreased as to not cause pot over...

Страница 28: ...r stove to see if they are properly working By using the ENTER button you can highlight Fire Exhaust Blower or Feeder When one of these options is highlighted you can use the SCROLL UP or SCROLL DOWN...

Страница 29: ...ry or damp rag If this does not clean the glass use any non abrasive cleaner Using ceramic stove top cleaner can be helpful in removing soot from the glass Inspect gaskets around the door periodically...

Страница 30: ...will effect the quality of the fire Make sureto clean any screens in the venting regularly A plugged screen will shut of combustion air and cause the fire to die or burn poorly DAILY MAINTENANCE The s...

Страница 31: ...and vacuumed thoroughly SEE FIGURE 36 This may require a hose adapter to reach inside the chamber This should be done monthly or with every 2 3 tons of fuel burned IMPORTANT NOTE A HOLE SHOULD BE CUT...

Страница 32: ...NOT OPERATE UNIT WITH PANELS REMOVED OR OPEN HOT PARTS DO NOT OPERATE THE UNIT WITH PANEL OPEN RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT IN THE EVENT OF COMPONENT FAILURE REPLACE...

Страница 33: ...door or ash pan not sealed No negative pressure in fire chamber Piping or stove may be plugged with ash The pressure sensor shuts off the feed auger when there is no negative pressure in fire chamber...

Страница 34: ...y PROBLEM CAUSE SOLUTION Fire burns lazy and smoky Stove is dirty Poor quality fuel Clean fire pot Clean ash pan Clean exhaust vent system Clean stove through cover plate clean out hole Increase exhau...