background image

Congratulations on purchasing your new HVAC equipment. It’s 

been designed for long life and reliable service, and is backed 

by one of the strongest warranties in the industry. Your unit 

automatically qualifies for the warranty coverage listed below, 

providing you keep your proof of purchase (receipt) for the 

equipment and meet the warranty conditions.
LIMITED ONE (1) YEAR EXPRESS WARRANTY

Comfort-Aire

 warrants this Room Air Conditioner to be free from 

defects in workmanship and materials for normal use and 

maintenance for one (1) year from the date of purchase by the 

original consumer. This Express Limited Warranty applies only when 

the Room Air Conditioner is installed and operated per 

Comfort-Aire

 

installation and operating instructions for normal use. 

EXCEPTIONS

The Limited Express Warranty does not cover normal maintenance 

Comfort-Aire

 recommends that regular inspection/maintenance be 

performed at least once a season. Additionally, labor charges  

diagnostic charges, transportation charges for replacement of 

refrigerant or filters, and any other service calls/repairs are not covered 

by this Limited Warranty. It also does not cover any portion or 

component of the system that is not supplied by 

Comfort-Aire

regardless of the cause of failure of such portion or component.

CONDITIONS FOR WARRANTY COVERAGE

Unit must be operated according to Comfort-Aire operating 

instructions 

included with the unit and cannot have been subjected 

to accident,

 

alteration, improper repair, neglect or misuse, or an act 

of God

 

(such as a flood)

• Serial numbers and/or rating plate have not been altered or

removed

Performance cannot be impaired by use of any product not

 

authorized by 

Comfort-Aire

, or by any adjustments or

 

adaptations

to

 

components

Damage has not been a result of inadequate wiring or voltage

 

conditions, use during brown-out conditions, or circuit interruptions

• Air flow around any section of the unit has not been restricted
• Unit remains in the original installation

DURATION OF WARRANTY & REGISTRATION

The warranty begins on the date of purchase by the original 

consumer. The consumer must retain a receipted bill of sale as proof 

of warranty period. Without this proof, the express warranty begins on 

the date of shipment from the factory.

REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY

The sole remedy under the Limited Warranty is replacement of the 

defective unit. Labor to diagnose and replace the defective unit is 

not covered by this Limited Express Warranty. If for any reason 

the replacement product is no longer available during the warranty 

period, 

Comfort-Aire

 shall have the right to allow a credit in the 

amount of the current suggested retail price of the product instead 

of providing replacement. 

LIMITATION OF LIABILITY

1.

There are no other express or implied warranties. 

Comfort-Aire

makes no warranty of merchantability. We do not warrant

 

that the

unit is suitable for any particular purpose or can be

used in buildings or rooms of any particular size or condition

 

except as specifically provided in this document. There are no

 

other warranties, express or implied, which extend beyond the

 

description in this document.

2.

All warranties implied by law are limited in duration to the one-term

of the warranty. 

We will not be liable for any consequential or

incidental damages caused by any defect in this unit.

3.

This warranty gives you specific legal rights and you may also have

 

other rights which vary from state to state. Some states do not allow

 

limitation on how long an implied warranty lasts or do not allow the

 

exclusion or limitation of incidental or consequential damages, so

 

the above limitations or exclusions may not apply to you.

4.

No warranties are made for units sold outside the continental

 

United States and Canada. Your distributor or final seller may

 

provide a warranty on units sold outside these areas.

5. Comfort-Aire

 will not be liable for damages if our

 

performance

regarding warranty resolution is delayed by events

 

beyond our

control including accident, alteration, abuse, war, government

restrictions, strikes, fire, flood, or other acts of God.

HOW TO SUBMIT A WARRANTY CLAIM

If you have a warranty claim, notify you installer or dealer promptly.  

KEEP THIS INFORMATION AS A RECORD OF YOUR PURCHASE

  PRODUCT IDENTIFICATION 

INSTALLATION

Model Number 

Installer Name (if used)

Serial Number 

Phone Number/Contact Information

Date of Purchase 

Date Installation Completed

Remember to retain your bill of sale as proof of warranty period.

LIMITED EXPRESS WARRANTY

Comfort-Aire

_

9

-2018

Please visit 

www.

marsdelivers

.com

 

to register your new product

Содержание PS-101D

Страница 1: ...www marsdelivers com Owner s Manual Installation Manual Portable Air Conditioner PS 81D PS 101D ...

Страница 2: ...Precautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation Kit Installation Troubleshooting Tips 03 11 11 12 12 12 12 13 13 14 16 18 19 19 21 21 21 21 22 ...

Страница 3: ...n the nameplate located on unit have a qualified electrician install the proper receptacle Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibration The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards Do not modify the length of the power cord or use an extension cord to power the unit Do not ...

Страница 4: ...the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the supply power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Prior to cleaning or other maintenance the appliance must be disconnected from the supply mains Do not remove any...

Страница 5: ...ontact a qualified person to carry out repairs If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired Hold the plug by the head of the power plug when taking it out Turn off the product when not in use WARNING for Using R32 R290 Refrigerant Do not use means to accelerate the defrosting process or to clean other than th...

Страница 6: ...nce of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Please follow the instructions carefully to handle install clear andservice the air conditioner to avoid any damage or hazard Flammable Refrigerant R32 is used within the air conditioner When maintaining or disposing of the air conditioner the refrigerant R32 shall...

Страница 7: ...e system 2 Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall b...

Страница 8: ...lly into the atmosphere 8 Checks to the refrigeration equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations using fl...

Страница 9: ...e the copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak Oxygen free nitrogen OFN shall then be purged through the system both before and during the brazing proc...

Страница 10: ...ractice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed refrigerant It is essential that electrical power is available before the task is commenced 15 Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedur...

Страница 11: ...tructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants In addition a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained...

Страница 12: ...ocedure not to the portable air conditioners themselves The energy rating and noise information for this unit is based on the standard installation using and un extended exhaust duct without window slider adapter as shown in the installation section of this manual At the same time the unit must operate on the COOL MODE and HIGH FAN SPEED by remote controller The unit with 10 feet extended exhaust ...

Страница 13: ...square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditioner s BTU British Thermal Unit rating which indicates the amount of heat it can remove from a room A higher Why is the cooling capacity lower on newer models than on older units number means more cooling power for a larger room Be sure you are comparing only newer models to...

Страница 14: ...Window Slider A Bolt 1 pc 1 set Unit Adaptor Security Bracket and 2 Screws 1 pc 1 pc Exhaust Hose Drain Hose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM E R O F F M O D E FA N S LE E P S W IN G LE D 1 pc Window Slider B Remote Controller and Battery only for remote control models 2 pc Foam Seal A Adhesive 2 pc Foam Seal B Adhesive 4 set Scr...

Страница 15: ...imes it needs to be cut short to meet the window size please take extra care to cut it properly 2 Use bolts to fasten the window sliders once they are adjusted to the Proper length Window slider A Window slider B Bolt Step Two Install the Exhaust hose assembly to the unit Push the Exhaust hose into the airoutlet opening of the unit along the arrow direction ...

Страница 16: ... sash and frame as shown Foam seal B Adhesive type shorter Foam seal A Adhesive type Or Or Window slider A Window slider B if required Foam seal C Non adhesive type 3 Cut the non adhesive foam seal C strip to match the width or height of the window Insert the seal between the glass and the window frame to prevent air and insects from getting into the room 2 Insert the window slider assembly into t...

Страница 17: ... range or bend the hose Make sure that there is no obstacle of 20 in in order to the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail Or 5 Insert the window slider adaptor into the hole of the window slider ...

Страница 18: ...e set temperature while on COOL HEAT or AUTO MODE While on DRY and FAN modes it shows the room temperature Shows Error codes E0 EEPROM error E1 Room temperature sensor error E2 Evaporator temperature sensor error E3 Condenser temperature sensor error on some models E4 Display panel communication error EC Refrigerant leakage detection malfunction on some models Shows protection code P1 Bottom tray ...

Страница 19: ...hows AP to indicate you can set wireless connection If connection router is successful within 8 minutes the unit will exit wireless connection mode automatically and the wireless indicator illuminates If connection has failed within 8 minutes the unit exits wireless connection mode automatically After Wireless connection is successful for some models you can press MODE and DOWN buttons at the same...

Страница 20: ... end of the hose is down to let the water flow smoothly When the continuous drain hose is not used ensure that the drain plug and knob are installed firmly to prevent leakage Continuous drain hose Remove the drain plug During heating pump mode remove the lower drain plug from the back of the unit install the drain connector 5 8 universal female mender with 3 4 hose locally purchased Carefully move...

Страница 21: ...the unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold Turn off the appliance and unplug it Clean the air filter according to the instructions in the previous section Reinstall th...

Страница 22: ...ician to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Double check the cooling area Turn off the unit disconnect the hose check for blockage and reconnect the hose Remove the heat sources if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surfa...

Страница 23: ... warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagnose and replace the defective unit is not covered by this Limited Express Warranty If for any reason the replacement product is no longer available during the warranty period Comfort Aire shall have t...

Страница 24: ... GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEOH UHJXODWLRQV LQ HIIHFW RQ GDWH RI PDQXIDFWXUH KRZHYHU FHUWLILFDWLRQV DUH QRW QHFHVVDULO JUDQWHG IRU WKH OLIH RI D SURGXFW 7KHUHIRUH LW LV WKH UHVSRQVLELOLW RI WKH DSSOLFDQW WR GHWHUPLQH ZKHWKHU D VS...

Отзывы: