SELECTION OF LOCATION
Select a convenient location where:
INDOOR UNIT
!
The cool air can reach every corner of the
area to be cooled.
!
The unit is away from any direct heat
source
!
Easy and short routing of the refrigerant
and drain pipes to the exterior.
!
There are no flammable gas, alkaline or
acid present in the air.
!
Air circulation is not obstructed, preventing
good air circulation.
!
The structure where the unit is installed
should be strong enough to support the
weight of the unit and also prevent any
vibration during operation of the unit.
!
Figure on the right shows the spacing to the
nearest wall.
OUTDOOR UNIT:
!
The condensing unit should be located as
close as possible to the fan coil.
!
The air inlet shall be located at least 4” from
the wall or other obstruction for unrestricted
airflow.
!
The air outlet shall be located so as to
direct discharged warm air away from the
building. (Avoid low overhanging roofs to
avoid re-circulation of condenser discharge
air on vertical discharge models.)
!
Mount the unit on a sturdy base.
!
Figure on the right shows the spacing to be
provided.