Model
Capacity
Modulation Specs for Ground Water Installation
EER/COP
HTV/HTD/
HTH024
Full
Part
BTUH: 28,900 cooling/25,700 heating
BTUH: 22,200 cooling/18,600 heating
24.5/4.8
30.8/5.1
HTV/HTD/
HTH036
Full
Part
BTUH: 41,200 cooling/36,700 heating
BTUH: 30,200 cooling/24,800 heating
23.0/4.7
31.5/5.1
HTV/HTD/
HTH048
Full
Part
BTUH: 54,600 cooling/48,300 heating
BTUH: 40,700 cooling/35,400 heating
22.5/4.7
28.7/5.1
HTV/HTD/
HTH060
Full
Part
BTUH: 68,600 cooling, 59,600 heating
BTUH: 51,900 cooling, 41,800 heating
22.0/4.4
29.7/4.7
HTV/HTD/
HTH070
Full
Part
BTUH: 77,100 cooling, 70,200 heating
BTUH: 59,800 cooling, 51,700 heating
19.9/4.3
24.5/4.3
BTUH Ratings: Cooling at 59
o
F
entering water temp; heating at
50
o
F entering water temperature.
HTV upflow
above; HTD
downflow
left; HTH
horizontal
far left.
Exceptional efficiency
with variable speed
ECM blower motor
and two-stage scroll
compressor. Features
microprocessor
controls and per-
formance moni-
toring system.
Model
Capacity
Modulation Specs for Ground Water Installation
EER/COP
HTS024
Full
Part
BTUH: 28,600 cooling/25,600 heating
BTUH: 22,000 cooling/19,200 heating
23.2/4.7
29.4/4.6
HTS036
Full
Part
BTUH: 40,100 cooling/35,900 heating
BTUH: 28,000 cooling/24,400 heating
21.4/4.5
27.1/4.6
HTS048
Full
Part
BTUH: 53,900 cooling/47,700 heating
BTUH: 38,700 cooling/33,800 heating
20.9/4.6
26.8/4.7
HTS060
Full
Part
BTUH: 63,800 cooling, 58,800 heating
BTUH: 46,000 cooling, 42,300 heating
19.2/4.3
25.7/4.4
BTUH Ratings: Cooling at 59
o
F entering water temperature;
heating at 50
o
F entering water temperature.
Exceptional efficiency
with full/part load
shifting and two-stage
scroll compressor.
Features, micropro-
cessor controls, quiet
operation and perfor-
mance monitoring
system.
GeoMax2® Two Stage Geothermal
Heat Pump
(Split)
COMFORT-AIRE GEOTHERMAL/WATER SOURCE EQUIPMENT
Model
Specs for Ground Water Installation
EER/COP
HPV018
BTUH: 20,600 cooling/17,200 heating
24.2/4.4
HPV024
BTUH: 26,700 cooling/24,000 heating
20.9/4.1
HPV030
BTUH: 31,700 cooling/29,600 heating
20.1/4.1
HPV036
BTUH: 38,700 cooling/37,500 heating
20.7/4.0
HPV042
BTUH: 45,900 cooling/44,000 heating
19.6/3.8
HPV048
BTUH: 54,300 cooling/46,500 heating
20.5/4.1
HPV060
BTUH: 66,600 cooling/60,000 heating
19.9/3.9
HPV Geothermal
Heat Pump
Efficient, single stage heat
pump 1
1
/
2
to 5 tons. With
performance monitoring
system and microproces-
sor controls. Large filter
improves indoor air quality.
Vertical cabinet, top air dis-
charge, left or right return.
GeoMax2® Two Stage Geothermal
Heat Pump
(Package)
BTUH Ratings:
cooling at 86
o
F
entering water
temperature;
heating at 68
o
F
entering water
temperature.
For a wide range of residential and industrial applications including
radiant floors, ice melting, potable hot water, etc. Capable of ground
water, ground loop and water loop applications, with microprocessor
controls, scroll compressor, performance monitoring system.
HWW Series Water-to-Water Systems
Model
Specs for Water Loop Installation
EER/COP
HWW036A
BTUH: 33,000 cooling/44,000 heating
14.6/5.0
HWW060B
BTUH: 52,800 cooling/72,700 heating
14.3/4.7
HWW120B
BTUH: 105,600 cooling/145,400 heating
14.1/4.6
208/230-1-60
7
208/230-1-60
BTUH Ratings: Cooling at 59
o
F entering water tempera-
ture; heating at 50
o
F entering water temperature.
208/230-1-60
Содержание A-VMH18DC