Model
Hi Fire Input Lo Fire Input
AFUE*
GTUV45-E3B
45,000
31,500
95.0%
GTUV60-E3B
60,000
42,000
95.0%
GTUV75-E3B
75,000
52,500
95.0%
GTUV75-E4B
75,000
52,500
95.0%
GTUV90-E5B
90,000
63,000
95.0%
GTUV105-E5B
105,000
73,500
95.0%
GTUV120-E5A
120,000
84,000
93.3%
95% Two Stage Gas Furnace
ECM variable speed blower motor
provides even temperatures and
improved indoor air quality. Two stage
design operates at low speed most of
the time to save energy, automatically
ramps up to second stage when there’s
demand. Upflow only.
115V-1-60
All models except -120 are Energy Star® rated.
Upflow
Down/Horiz
Input BTUH
AFUE*
GLUB45-E3A
GLDB45-E3A
45,000
95.0%
GLUB60-E3A
GLDB60-E3A
60,000
95.0%
GLUB75-E3A
—
75,000
95.0%
GLUB75-E4A
GLDB75-E4A
75,000
95.0%
GLUB90-E5A
GLDB90-E5A
90,000
95.0%
GLUB105-E5A
GLDB105-E5A
105,000
95.0%
95% Single Stage Gas Furnace
Two heat exchangers for efficiency,
electronic ignition, integrated
furnace control with on-board
diagnostics, and easy-change filter.
Low profile cabinet is ideal
for replacements.
115V-1-60
*AFUE=Annual Fuel Utilization Efficiency
Upflow
AFUE*
Input BTUH
Down/Horiz
AFUE*
GLUA45-E3B
93.5%
45,000
GLDH45-E3B
92.0%
GLUA60-E3B
92.5%
60,000
GLDH60-E3B
92.4%
GLUA75-E3C
92.8%
75,000
GLDH75-E3B
92.0%
GLUA75-E4C
92.0%
75,000
GLDH75-E4B
92.3%
GLUA90-E4B
93.5%
90,000
GLDH90-E4B
92.4%
GLUA105-E5B
92.0%
105,000
GLDH105-E5B
92.0%
GLUA120-E5B
93.5%
120,000
GLDH120-E5B
92.1%
92% Single Stage
Gas Furnace
Two heat exchangers, direct
spark ignition for reliability,
integrated furnace control
with on-board diagnostics,
and easy-change filter. Low
profile cabinet is ideal for
replacements.
115V-1-60
2
Down/Horiz = Downflow/Horizontal Configuration
Upflow/Horiz.
AFUE GMUH Input BTUH
Downflow
AFUE GMDA
GMUH50-E3A
81.4%
50,000
GMDA50-E3A
82.2%
GMUH75-E3A
80.6%
75,000
GMDA75-E3A
80.5%
GMUH75-E4A
80.5%
75,000
GMDA75-E4A
81.1%
GMUH100-E3A
80.0%
100,000
GMDA100-E3A
80.2%
GMUH100-E5A
80.0%
100,000
GMDA100-E5A
80.0%
GMUH125-E5A
80.0%
125,000
GMDA125-E5A
80.0%
GMUH150-E5A
80.0%
150,000
GMDA150-E5A
80.0%
80% Gas Furnace
Non-condensing 80%
gas furnace features
direct spark ignition,
in-shot burner and
tubular heat exchanger.
Low profile cabinet
fits virtually any space.
LP conversion kits are
available.
115V-1-60
Uncased Coils
Upflow/counter-
flow, 1
1
/
2
to 5 ton
capacities.
CSG Series
Cased Coils
Upflow/counterflow,
1
1
/
2
to 5 ton capa-
cities. Durable cabi-
net.
VHG Series
Cased Coils
Multi-position,
1
1
/
2
to 5 ton
capacities.
Durable cabinet.
MHG Series
Full range of coils for split system A/C installations—all with TXV
Minimum 13 SEER with RSG13 units, 14 SEER with RSG14 units; 13 SEER with HRG13 heat pumps
Содержание A-VMH18DC