V. Trouble Shooting 

Before operation, open terminal box of motor to ascertain the corrective wirings. 

Checking winch for smooth operation by pressing up and down button of push button 

switch. 

When winch fails to start after several attempts, or and defective operation to be 

happened, check followings. 

 

Observed anomaly 

Possible cause 

Solution 

No power 

Check power source 

Disconnection of the plug, power 

Replace or repair 

Burnt or communicated motor 

Replace 

Burnt diode ass’y 

Replace, clean motor 

 

 

No reaction 

Considerable voltage down 

Ascertain the corrective input 

Overload 

Reduce load 

Check voltage 

 

Lifting speed to be slow 

Considerable voltage down 

Check the section of power cable 

Burnt motor resulting from 

Replace motor 

Carbon brush worn down 

Replace it and clean powder left 

Dry 

 

 

Electricity leakage or shock 

Water invaded in motor or push 

button switch 

Replace 

Brake lining worn down 

Replace 

Burnt D type resistor 

Replace 

 

Breaking distance more the 1.5% 

 

Voltage too high 

Check power source 

Replace oil seal 

Insufficient oil resulting from oil 

leakage 

Fill with sufficient oil 

 

Large noise in gear box   

Distortion of gear box 

Repair 

 
 
 
 
 
 

 

Содержание CWL-301L

Страница 1: ......

Страница 2: ...ed to the drum Don t use unsuitable pulleys or accessories concerned Don t use unsuitable rope in construction strength or having any defects Pay attention to the grounding it provides a path of least...

Страница 3: ...D diameter mm 4 5 6 6 5 length M 24 71 30 55 46 Wire rope construction 6 x 19 6 x 19 6 x 19 6 x 19 6 x 19 General Safety Precaution Danger The following environmental conditions may result in the poss...

Страница 4: ......

Страница 5: ...Rope Replacement Insert the wire rope into the hole of drum and fix it with a P T screw then press the UP button of switch for rotate the drum in the lifting direction Wind the wire rope accurately a...

Страница 6: ...s SP 220 a viscosity cSt is 226 14 19 5 at 40 100 Consult your local lubricant distributor on the selection that best fits your climate and application The initial lubricant should be changed after th...

Страница 7: ...perating time and take into consideration so as to obtain the suitable time for intermediate inspection and arrangement Calculating Head Loads P Rope tension Sheave coefficient Angle W Load Friction f...

Страница 8: ...l To be free from exposure of conductive wire Attaching condition of earth line Visual Existence of abnormalities of connecting wires Control Switch Condition of insulation Measure with 500v insulatio...

Страница 9: ...g up of load Condition of rope winding in Visual To be free from irregular winding Condition of feed oil Visual To be not insufficient in feed out Wire Rope Confirming of dead turn of rope Visual Conf...

Страница 10: ...ss y Replace clean motor No reaction Considerable voltage down Ascertain the corrective input Overload Reduce load Check voltage Lifting speed to be slow Considerable voltage down Check the section of...

Страница 11: ...VI Replacement Parts List CWL 80...

Страница 12: ...Replacement Parts List CWL 200...

Страница 13: ...CWL 200L...

Страница 14: ...Replacement Parts List CWL 301 301L...

Отзывы: