Starting up the unit
Requirements
✓
Coolant hoses connected, see "Connecting the coolant hoses".
✓
Cooling water hoses connected, see "Connecting the cooling water hoses".
✓
Coolant added, see "Adding coolant".
✓
Unit connected electrically, see "Connecting the unit electrically".
Procedure
•
Start the unit using the controls of the device to be cooled.
•
Let the unit run for approximately 10 minutes with coolant filler plug mounted.
•
Switch off the unit using the controls of the device to be cooled.
•
Dismount the coolant filler plug.
•
Check coolant level and top up, if necessary, see "Adding coolant".
•
Mount the coolant filler plug.
•
Restart the unit.
•
Check whether the operating specifications are met; see "Technical specifications".
The unit is operational.