25
EN
4.5 MONITOR RINGTONE SELECTION ART. EX-7000H
1.
Press and hold
for 6 sec.
» a confirmation tone will sound
» the Privacy LED will flash to indicate “programming” mode.
√
The procedure can only take place while the system is in standby; otherwise the Privacy LED will flash 4 times to inform the user that the
system is engaged.
2.
Press and release
:
Once
(1 confirmation tone is emitted) to change the ringtone for calls from the external unit.
Twice
(2 confirmation tones are emitted) to change the ringtone for calls from the switchboard.
3 times
(3 confirmation tones are emitted) to change the ringtone for intercom calls made from the internal unit.
4 times
(4 confirmation tones are emitted) to change the floor door call ringtone.
Any further pressing of the
key repeats the sequence described above.
3.
Press and release to scroll through the various available ringtones in sequence.
4.
Press to confirm selection of the last ringtone heard and to exit (at any time) change monitor ringtone mode.
» one confirmation tone is emitted
» the Privacy LED switches off
5.
Repeat steps 1 to 4 to change the other ringtones.
4.6 CONFIGURATION EX-DSME
4.6.1 External unit addressing
f
Set the
S1
DIP-switches corresponding to the address that you want to set as shown in the table below
EXTERNAL UNIT ADDRESSING
DIP 1
DIP 2
DIP 3
CODE
0
0
0
0 *
1
0
0
1
0
1
0
2
0
0
1
3
* Default
4.6.2 Function programming
f
Set the
S1
DIP-switches corresponding to the function that you want to programme as shown in the table below
DIP S1
FUNCTION
DIP 4
The lock-release relay and the second relay are controlled by 2 separate buttons (e.g. lock-release button and
actuator button)
*
The lock-release relay and the second relay are controlled by a single button (e.g. lock-release button)
DIP 5
Lock-release activation time and relay activation time: 8 sec
*
lock-release activation time and relay activation time: 2 sec
DIP 6
Confirmation tones (call, lock-release, relay, audio enabled): disabled
*
Confirmation tones (call, lock-release, relay, audio enabled): enabled
DIP 7
Camera lighting LED: disabled
*
Camera lighting LED: enabled
DIP 8
Reset wait time: 1 sec.
*
Reset wait time: 10 sec.
* Default