background image

3

Programming and operation

There is a timeout for programming procedures after which the operation is cancelled (around 40” between successive 

keystrokes); we recommend familiarising yourself with the procedure before starting it.

Entering the supercode

Example
To enter supercode 12345, proceed as follows:

• 

move the jumper to the ON programming position;

• 

connect the module to the corresponding wired and powered terminal;

• 

enter in sequence 1 2 3 4 5 E;

• 

wait for 10 seconds or for the confirm tone to sound;

• 

move the programming jumper to its previous OFF position.

Description

Art. 3348B / 3348BM for mounting in iKall modular keypads for mixed access control - entry panel - video entry panel 

installations or stand-alone applications.

Programming the supercode is the first operation, because all subsequent steps depend on it. 

We recommend using a short, easy to remember supercode, or noting it down on a sheet of paper.

Procedura di inserimento del supercodice
 1.

 Move jumper to the ON position (see figure).

 2.

 Connect the module to the corresponding wired and powered terminal.

 3.

 Check that the red LED has lit up.

 4.

 Enter the supercode (1 to 8 digits).

 5.

 Press “

E

” to store the code.

 6.

 Wait for 10 seconds or for the confirm tone to sound.

 7.

 Move jumper to the OFF position (see figure).

3

1

OFF ON

2

 1. 

Jumper for entering supercode

 2.

 Connector to be used for connection to Simplebus system.

 3.

 Switch for selecting the LED lighting colour. Leave the switch set to OFF for Simplebus systems

TERMINAL BLOCK - DESCRIPTION

~ –  ~ +

power supply 12V DC/AC

CK

“key” button enable input

AL+

alarm and anti-coercion output, max. 100 mA

NO2 – C2– NC2 

relay 2

NO1 – C1– NC1 

relay 1

negative

RK

remote key input

D+ D–

RS 485 line connection

Содержание 3348B

Страница 1: ...EN PROGRAMMING MANUAL Digital electronic key module Art 3348B 3348BM Passion Technology Design...

Страница 2: ...first programming 4 Using relay codes 4 Cancelling relay codes 4 Bistable Monostable operation 5 Anti coercion function 5 Programming the allowed errors number 6 Programming the relay 1 activation del...

Страница 3: ...supercode is the first operation because all subsequent steps depend on it We recommend using a short easy to remember supercode or noting it down on a sheet of paper Procedura di inserimento del supe...

Страница 4: ...entering 55127 E In this example the operating mode has been set to 0 in other words bistable on off To activate monostable operation see Bistable Monostable operation Up to 400 codes can be set rela...

Страница 5: ...off Example To set an anti coercion code of 3 enter in sequence 0 E start procedure 12345 E supercode 4 E anti coercion function 3 E anti coercion code Example If relay 1 was activated with code 55127...

Страница 6: ...9 but DO NOT enter E 6 Enter 1 E to send an alarm when the key is locked 0 E if you do not wish to send an alarm 7 The LED should now turn off Example To set the activation time to 10 seconds enter i...

Страница 7: ...uiting terminals CK and for example via a timer makes it possible to activate relay 1 without entering the relay code but by simply pressing the key button REMOTE KEY INPUT RK Closing this contact wit...

Страница 8: ...Yes Contact capacity 24V AC DC MAX Service output max 100 mA Switch Switch C on the back of the module for selecting the LED lighting colour Leave the switch set to OFF for Simplebus systems Operatin...

Страница 9: ...9...

Страница 10: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 1 ST edition 07 2017 code 2G40001935 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: