7
Cancelling the actuator function:
1.
Enter “
0
” and “
E
” (start programming procedure code).
2.
Check that the LED has lit up.
3.
Enter the supercode (see
"Entering the supercode"
), then da “
E
”.
4.
Enter the number “
7
” ("actuator" function) followed by “
E
”.
5.
Enter “
0
” and “
E
”
6.
The LED should now turn off.
ENABLING THE “KEY” BUTTON
Short-circuiting terminals
CK
and -, for example via a timer, makes it possible to activate relay 1 without entering the relay
code but by simply pressing the “key” button
REMOTE KEY INPUT (RK)
Closing this contact with ground activates relay 1 for the set time (see
"Programming the relay 1 activation delay for a
remote key input"
). The contact can be connected remotely up to 20 m max.
Example
Programming the actuator function:
•
0 E
start procedure
•
12345 E supercode
•
7 E
actuator function
•
1 E
relay number
•
10 E
relay closure time