42
• WAIT TIME
This is the time interval (expressed in seconds) between the arrival
of a call and its diversion (in the case of no reply) to another ViP
device. Adjust by pressing "+" and "-".
The wait time value only applies when the ACTIVATE TIMED DIVERT
function is enabled (see below).
• ACTIVATE TIMED DIVERT
Selecting this function activates call divert in the event of no reply
or absence.
• ACTIVATE DIVERT WHEN BUSY
Selecting this function activates call divert if a call is received
when the device is already busy with another call.
If the CALL DIVERT function has been CONFIGURED, then the
Door entry system menu will display an icon for the rapid activation/
deactivation of the function.
10/04
16:35
______________________________
Alarms
Setup_Installer setup menu_Alarms
From this menu you can set and manage a series of previously
programmed emergency/alarm calls to a CPS.
Consult your installer for configuration of alarm calls!
Allarme
Panico
Incendio
Chiamata prioritaria 4
Alarm
Panic
Fire
Priority call 4
Press next to the required call type to open the corresponding
sub-menu.
• CONFIGURE VIP ADDRESS
Allows you to enter the address of the device to which the
emergency call is made.
See paragraph
“CONFIGURE VIP ADDRESS" on page 39
______________________________
Home automation
Setup_Installer setup menu_Home automation
This section can be used to set parameters for correct communication
with the home automation system via Comelit Hub.
Comelit Hub ViP address
User
Password
Enable home automation
Reset home automation server parameters
COMHUB01
admin
1.
2.
3.
4.
5.
1.
Enter the ViP address assigned to the Comelit Hub
2.
Enter the user name assigned to the Comelit Hub
3.
Enter the password assigned to the Comelit Hub
4.
Enable to allow communication between Maxi Manager and the
Comelit Hub
5.
Press to restore the factory settings for the menu parameters
______________________________
Ethernet reporting not connected
Setup-Installer setup menu-Ethernet reporting not connected
Enable the function to receive an alert in the event of a cable fault or
incorrect Ethernet connections.
Press to enable/disable the function.
______________________________
Master not connected signal
Setup-Installer setup menu-Master not connected signal
Enable this function to receive an alert if there is no communication
with the ViP master device.
Press to enable/disable the function.