Comelit 1998A Скачать руководство пользователя страница 3

3

Table of contents

Warning ............................................................................................ 2

Description ....................................................................................... 4

Programming keys and display ...............................................................5
Alphanumeric keypad ..............................................................................5
General description ..................................................................................6

Technical features ........................................................................... 6

Connection ....................................................................................... 7

Operation .......................................................................................... 8

U1 How to answer a call from an internal unit ....................................8
U2 How to answer a call from an external unit ...................................8
U3 How to call an internal unit ............................................................8
U4 How to transfer a call from the external unit to an internal unit.....9
U5 How to set up communication between 2 internal units (intercom 
function) ..............................................................................................9
U6 How to call an internal unit listed in the call log ............................9
U7 How to use the directory .............................................................10
U8 How to enter a name in the directory ..........................................10
U9 How to find a name in the directory ............................................10
U10 How to delete a name in the directory ......................................10
U11 How to change a name in the directory ....................................10
U12 How to use the lock-release......................................................11
U13 Day/night operating mode .........................................................11
U14 How to activate the “Follow me” function (available from R.I.006) 11
U15 Alarm signalling (available from R.I.006) ...................................11
U16 How to activate an additional relay Art. 1256 (e.g. to activate the 
following independently and with a specific command: lights, CCTV 
alarm contacts, driveway gates, entrances without external units or 
other devices) (available from R.I.006) ..............................................11
U17 How to call a secondary switchboard from a main switchboard 
(available from R.I.006) .....................................................................12
U18 How to call a main switchboard from a secondary switchboard 
(available from R.I.006) .....................................................................12
U19 How to answer a call from the secondary switchboard to the main 
switchboard (available from R.I.006) .................................................12
U20 How to answer a call from the main switchboard to the secondary 
switchboard (available from R.I.006) .................................................12
U21 How to activate (MASTER) or deactivate (SLAVE) the main 
switchboards (available from R.I.006) ...............................................13

Settings .......................................................................................... 14

I1 - Change time ...............................................................................15
I2 - Change date ...............................................................................15
I3 - Day/night automatic mode .........................................................15
I3.1 - Activation/deactivation ............................................................15
I3.2 - Set times in auto mode ...........................................................15
I3.3 - Weekly programming ...............................................................15
I4 - Recording speed number ...........................................................16
I5 - Change language .......................................................................16
I6 - Downloard names from pc .........................................................16
I7 - All names delete .........................................................................16

Configurations ............................................................................... 17

C8.1 - Video mode configuration  .....................................................18
(available from R.I.006) .....................................................................18
C8.2 - Calling mode (available from R.I.006) ....................................18
C8.3 - Type of switchboard (Simplebus Top mode) (available from 
R.I.006)   ............................................................................................18

How to configure a main switchboard .......................................19
How to configure a secondarya switchboard ............................19

C8.4 -  Self-ignition on/off (available from R.I.006) ...........................19
C8.5 - Triple call on/off  (available from R.I.006) ...............................20
C8.6 - Function CH-CH contact (available from R.I.006) ..................20
C8.7 - Function main cps+sec (available from R.I.006) ....................20

System performance and layouts ................................................ 20

Содержание 1998A

Страница 1: ...EN TECHNICAL MANUAL Porter switchboard Art 1998A Passion Technology Design...

Страница 2: ...s the power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using...

Страница 3: ...vailable from R I 006 11 U17 How to call a secondary switchboard from a main switchboard available from R I 006 12 U18 How to call a main switchboard from a secondary switchboard available from R I 00...

Страница 4: ...NABLE EXTERNAL MONITOR OUT OUT CNO output for remote camera control C NO Normally open contact for FOLLOW ME function TX RX GND Serial port RS232 for connection to the PC in order to download the name...

Страница 5: ...onfigured in parallel S indicates that the switchboard is configured in series 9 fixed indicates correct operation of the serial line flashing indicates malfunctioning of the serial line LM KO indicat...

Страница 6: ...ORY which can be programmed so as to identify the caller easily Technical features MAIN FEATURES Product height inch 9 06 Product width inch 6 3 Product depth inch 3 94 Operating temperature F 23 104...

Страница 7: ...AUTO 14 40 MER 12 03 10 24 T X R X 0 L M L M C H C H G N D L P 2 L P 1 O U T O U T N O C 1195 1 2 1 2 0 2 3 0 0 2 4 RS 232 FOR DOWNLOADING NAMES IN DIRECTORY VIA 1249 A Free contact for CALL REP or E...

Страница 8: ...call originating from the internal unit lift the handset within 30 seconds the switchboard begins communicating with the external unit the maximum duration of the conversation is 2 5 minutes COMMUNICA...

Страница 9: ...the conversation hang up the handset U5 How to set up communication between 2 internal units intercom function When the switchboard is communicating with an internal unit e g 002 which is trying to s...

Страница 10: ...ad if the indirect code calling mode has been activated see C8 2 Calling mode available from R I 006 7 to confirm code entry press OK 8 it will now be possible to enter a new name alternatively press...

Страница 11: ...peat the procedure so that the initial screen appears on the display A D _ _ 14 40 WED 12 03 10 Once a call has been made the switchboard will ring until the remote device begins communicating the cal...

Страница 12: ...ITCHBOARD f f to end the conversation hang up the handset If the call has not taken place correctly if the system is busy or if the main switchboard does not exist the display shows FUNCTION NOT AVAIL...

Страница 13: ...r 1 MASTER 2 SLAVE f f press 2 to deactivate it SLAVE The switchboard will switch off while the other switchboard will switch on automatically to become the MASTER or press ON OFF on the deactivated s...

Страница 14: ...directory etc Menu 1 7 screens tree diagram 1 CHANGE TIME SET TIME 00 00 2 CHANGE DATE SET DATE 00 00 00 3 DAY NIGHT AUTOMATIC 1 ON OFF SERVICE ACTIVE SERVICE NON ACTIVE 2 SET TIMES TIME 01 00 00 TIM...

Страница 15: ...2 determines the second mode switch from DAY mode to NIGHT mode TIME 3 determines the third mode switch from NIGHT mode to DAY mode TIME 4 determines the fourth mode switch from DAY mode to NIGHT mode...

Страница 16: ...ess 5 5 CHANGE LANGUAGE 2 use the keys to display the selected language and press the corresponding button e g 2 for English 1 ITALIAN 2 ENGLISH 3 press ESC repeatedly to return to the main screen I6...

Страница 17: ...ARY 1 SINGLE CPS 2 PARALLEL CPS function not available 3 SERIES CPS 1 MASTER 2 SLAVE 2 MAIN SIMPLEBUS TOP mode 1 SINGLE CPS 2 PARALLEL CPS 1 LS IN 2 LP IN 3 SERIES CPS 1 MASTER 2 SLAVE 4 SELF IGNITION...

Страница 18: ...name field is not compulsory In this mode FILTER OFF or FILTER ON will be requested if activated only named users will appear on the display however if the filter is deactivated all users will be disp...

Страница 19: ...IONS 2 use the keys to display the 3 TYPE OF SWITCHBOARD menu then press 3 3 TYPE OF SWITCHBOARD 3 press 2 1 SECONDARY 2 MAIN The switchboard is configured as SINGLE CPS by default It is now possible...

Страница 20: ...CH CONTACT menu then press 6 6 FUNCTION CH CH CONTACT 3 press 1 for the CALL REPLY function or 2 for the EXTERNAL MONITOR function 1 CALL REPLY 2 EXT MONITOR if key 1 has been selected the CONTACT TIM...

Страница 21: ...21...

Страница 22: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 5 edizione 09 2018 cod 2G40002108 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: