Comelit 1998A Скачать руководство пользователя страница 19

19

device positioned underneath the LPin-LPin line of 

switching device Art. 1424 as 

LP-IN

For the PARALLEL switchboard, switching to NIGHT 

and the DAY/NIGHT AUTOMATIC function is not 

possible (see 

”I3 - Day/night automatic mode”

 ). 

P

 should appear on the standby screen of the two 

switchboards, indicating that the switchboard is 

configured in parallel, in addition to the fixed icon  .

3-

  If there are 2 main or secondary switchboards serving the 

same riser, the SERIES configuration implies that only 1 

of the 2 can be operative (MASTER switchboard), while 

the other is deactivated (SLAVE switchboard) (see 

SBTOP 

audio/video system

).

 

f

 Configure both switchboards as SERIES and the 

active switchboard will, from time to time, be the one 

set as MASTER. To change a switchboard from 

MASTER to SLAVE and vice-versa, see “U21 How to 

ACTIVATE (MASTER) or DEACTIVATE (SLAVE) the main 

switchboards” page 13. 

An 

S

 should appear on the standby screen of the two 

switchboards, indicating that the switchboard is 

configured in series, in addition to the fixed icon   .

CAUTION! 

 

» if   flashes, it is indicating that the 2 switchboards are 

not communicating correctly.

 

» if the icon ! appears, there is a configuration problem 

with the 2 switchboards 

(e.g. both set as MASTER 

or SLAVE, LP-IN or LS-IN, or one is SERIES and the 

other PARALLEL).

 

»  If, in a Simplebus TOP system (with switching devices 

Art. 1424), both main and secondary switchboards are 

installed 

(see 

SBTOP audio/video system

); for correct 

system operation, it will be necessary to activate - on 

all switchboards - the setting 

”C8.7 - Function main 

cps+sec (available from R.I.006)”

.

How to configure a main switchboard

1.

  press the 

MENU

 key and use the  

 keys to view the 

8-ADVANCED OPTIONS

 menu, then press 

8

;

8-ADVANCED  

OPTIONS

2.

  use the 

 keys to display the 

3-TYPE OF 

SWITCHBOARD

 menu, then press 

3

;

3- TYPE OF

SWITCHBOARD

3.

 press 

2

;

1- SECONDARY

*

2- MAIN

The switchboard is configured as SINGLE CPS by default. 
It is now possible to configure it as PARALLEL CPS or 

SERIES CPS.

 

f

to configure it as

 2-PARALLEL CPS

, press 

2

1-SINGLE CPS

*

2- PARALLEL CPS

 

f

to configure it as 

LS-LN

, press 

1

,  

to configure it as 

LP-LN

, press 

2

1- LS-IN

2- LP-IN

 

f

to configure it as SERIES CPS, use the 

 keys to 

display the 

3-SERIES CPS

 menu, then press 

3

*

3- SERIES CPS

 

f

to configure it as 

MASTER

, press 

1

to configure it as 

SLAVE

, press 

2

1- MASTER

2- SLAVE

How to configure a secondarya switchboard

1.

  press the 

MENU

 key and use the  

 keys to view the 

8-ADVANCED OPTIONS

 menu, then press 

8

:

8-ADVANCED  

OPTIONS

2.

  use the 

 keys to display the 

3-TYPE OF 

SWITCHBOARD

 menu, then press 

3

;

3- TYPE OF

SWITCHBOARD

3.

  Press key 

1

;

*

1- SECONDARY

2- MAIN

The switchboard is configured as SINGLE CPS by default.
It is now possible to configure it as SERIES CPS, in fact 

the 

function 2-PARALLEL CPS IS NOT AVAILABLE;

*

1- SINGLE CPS

2- PARALLEL CPS

 

f

to configure it as SERIES CPS, use the 

 keys to 

display the

 3-SERIES CPS

 menu, then press 

3

*

3- SERIES CPS

 

f

to configure it as 

MASTER

, press 

1

; to configure it as 

SLAVE

, press 

2

1- MASTER

2- SLAVE

C8.4 -  Self-ignition on/off (available from R.I.006)

This is disabled by default.

This function is only available for non-TOP Simplebus 

systems and requires Art. 1259 for the cyclic displaying of 

images from remote cameras.
This function can be used to activate or deactivate the self-

ignition transmitted by the internal units with the switchboard 

in DAY mode.

 

To activate the function:

1.

  press the 

MENU

 key and use the  

 keys to view the 

8-ADVANCED OPTIONS

 menu, then press 

8

8-ADVANCED  

OPTIONS

2.

  use the  

 keys to view the 

4 SELF-IGNITION ON/OFF

 

menu; 

4-AUTO ACC.

INTERNA ON/OFF

3.

 press 

4

 to activate or deactivate the function;

SERVICE     

ACTIVE

 

SERVICE     

NON ACTIVE

Содержание 1998A

Страница 1: ...EN TECHNICAL MANUAL Porter switchboard Art 1998A Passion Technology Design...

Страница 2: ...s the power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using...

Страница 3: ...vailable from R I 006 11 U17 How to call a secondary switchboard from a main switchboard available from R I 006 12 U18 How to call a main switchboard from a secondary switchboard available from R I 00...

Страница 4: ...NABLE EXTERNAL MONITOR OUT OUT CNO output for remote camera control C NO Normally open contact for FOLLOW ME function TX RX GND Serial port RS232 for connection to the PC in order to download the name...

Страница 5: ...onfigured in parallel S indicates that the switchboard is configured in series 9 fixed indicates correct operation of the serial line flashing indicates malfunctioning of the serial line LM KO indicat...

Страница 6: ...ORY which can be programmed so as to identify the caller easily Technical features MAIN FEATURES Product height inch 9 06 Product width inch 6 3 Product depth inch 3 94 Operating temperature F 23 104...

Страница 7: ...AUTO 14 40 MER 12 03 10 24 T X R X 0 L M L M C H C H G N D L P 2 L P 1 O U T O U T N O C 1195 1 2 1 2 0 2 3 0 0 2 4 RS 232 FOR DOWNLOADING NAMES IN DIRECTORY VIA 1249 A Free contact for CALL REP or E...

Страница 8: ...call originating from the internal unit lift the handset within 30 seconds the switchboard begins communicating with the external unit the maximum duration of the conversation is 2 5 minutes COMMUNICA...

Страница 9: ...the conversation hang up the handset U5 How to set up communication between 2 internal units intercom function When the switchboard is communicating with an internal unit e g 002 which is trying to s...

Страница 10: ...ad if the indirect code calling mode has been activated see C8 2 Calling mode available from R I 006 7 to confirm code entry press OK 8 it will now be possible to enter a new name alternatively press...

Страница 11: ...peat the procedure so that the initial screen appears on the display A D _ _ 14 40 WED 12 03 10 Once a call has been made the switchboard will ring until the remote device begins communicating the cal...

Страница 12: ...ITCHBOARD f f to end the conversation hang up the handset If the call has not taken place correctly if the system is busy or if the main switchboard does not exist the display shows FUNCTION NOT AVAIL...

Страница 13: ...r 1 MASTER 2 SLAVE f f press 2 to deactivate it SLAVE The switchboard will switch off while the other switchboard will switch on automatically to become the MASTER or press ON OFF on the deactivated s...

Страница 14: ...directory etc Menu 1 7 screens tree diagram 1 CHANGE TIME SET TIME 00 00 2 CHANGE DATE SET DATE 00 00 00 3 DAY NIGHT AUTOMATIC 1 ON OFF SERVICE ACTIVE SERVICE NON ACTIVE 2 SET TIMES TIME 01 00 00 TIM...

Страница 15: ...2 determines the second mode switch from DAY mode to NIGHT mode TIME 3 determines the third mode switch from NIGHT mode to DAY mode TIME 4 determines the fourth mode switch from DAY mode to NIGHT mode...

Страница 16: ...ess 5 5 CHANGE LANGUAGE 2 use the keys to display the selected language and press the corresponding button e g 2 for English 1 ITALIAN 2 ENGLISH 3 press ESC repeatedly to return to the main screen I6...

Страница 17: ...ARY 1 SINGLE CPS 2 PARALLEL CPS function not available 3 SERIES CPS 1 MASTER 2 SLAVE 2 MAIN SIMPLEBUS TOP mode 1 SINGLE CPS 2 PARALLEL CPS 1 LS IN 2 LP IN 3 SERIES CPS 1 MASTER 2 SLAVE 4 SELF IGNITION...

Страница 18: ...name field is not compulsory In this mode FILTER OFF or FILTER ON will be requested if activated only named users will appear on the display however if the filter is deactivated all users will be disp...

Страница 19: ...IONS 2 use the keys to display the 3 TYPE OF SWITCHBOARD menu then press 3 3 TYPE OF SWITCHBOARD 3 press 2 1 SECONDARY 2 MAIN The switchboard is configured as SINGLE CPS by default It is now possible...

Страница 20: ...CH CONTACT menu then press 6 6 FUNCTION CH CH CONTACT 3 press 1 for the CALL REPLY function or 2 for the EXTERNAL MONITOR function 1 CALL REPLY 2 EXT MONITOR if key 1 has been selected the CONTACT TIM...

Страница 21: ...21...

Страница 22: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 5 edizione 09 2018 cod 2G40002108 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: