background image

Comco Inc

2151 N. Lincoln St. Burbank, CA 91504 USA

[email protected] 

1‐818‐841‐5500

Содержание AccuFlo AF10-E

Страница 1: ...Comco Inc 2151 N Lincoln St Burbank CA 91504 USA Tech comcoinc com 1 818 841 5500 ...

Страница 2: ...0 lb 13 6 kg Height 10 5 in 26 7 cm 15 0 in 38 1 cm Width 17 5 in 44 5 cm 17 5 in 44 5 cm Depth 10 0 in 25 4 cm 10 0 in 25 4 cm Air Pressure 10 125 psi 0 7 8 6 bar 10 125 psi 0 7 8 6 bar Powder Capacity 1 liter 2 liters Nozzle Sizes Round 015 060 in Ø 38 mm 1 5 mm Other shapes sizes available Facility Requirements Inlet Air Pressure 70 145 psi 4 8 10 bar Air Volume Depending on nozzle size and air...

Страница 3: ...wderGate valve traveling out to the nozzle The strength of these modulated pulse and the diameter of the orifice determines the amount of abrasive that drops into the mixing chamber Three mechanisms enable you to change the amount of abrasive in the air stream the tank orifice abrasive blend and bypass tube Tank Orifice A larger orifice increases abrasive flow In most cases the orifice should be a...

Страница 4: ... accessory kit INLET AIR FITTING THE ABRASIVE HOSE FROM THE POWDERGATE VALVE RUNS DIRECTLY TO THE NOZZLE DO NOT ROUTE THIS HOSE THROUGH THE VENT PINCH Add Abrasive 1 Remove the tank cover 2 Fill the tank with powder Do not fill above the top of bypass tube 3 Replace the tank cover and secure only turn required VENT HOSE IS ROUTED THROUGH THE VENT PINCH TO NOZZLE S Always maintain a 10 psi buffer b...

Страница 5: ...bonded to PE do not use this pin Regulator Control The regulator must be powered by 24vdc through Pin 7 and ground through Pin 6 The regulator requires 60mA of current The blast pressure is set by providing a 0 10vdc signal at Pin 8 which corresponds to a pressure of 0 148psi The internal resistance of the regulator s input is 100ohms minimum AF10 E Cables and Controllers Cabling and control depen...

Страница 6: ...icher more abrasive by changing the tank orifice and bypass tube Contact a Comco Tech Support Specialist for information on additional options Change the tank orifice using a nut driver Unscrew the bypass tube and lift it out of the sleeve Using the chart below select the tube you desire and insert it in the sleeve Finger tighten only do not force Bypass Tube Chart TANK ORIFICE MB1409 BYPASS TUBE ...

Страница 7: ...w Nose Install the new Output Fitting Connect the tubing with the blue Quicknut Tune Up Kits ABRASIVE HOSE MB1233 POWDERGATE OUTPUT FITTING MB2560 x POWDERGATE NOSE MB1653 TUNE UP KIT MB2247 x MB2247 2 1 4 output fitting MB2247 3 3 8 output fitting PowderGate Output Fitting MB2560 3 MB2560 4 PowderGate Nose MB1653 O ring ST5650 242 In addition to the tune up kit we also recommend that you keep a b...

Страница 8: ...8 1 818 841 5500 AF10 E Components ...

Страница 9: ...aintenance The HRS counter records the number of blast hours i e actual time the modulator has operated Your maintenance requirements may vary with your application The modulator should be replaced after 5000 hours of operation To replace the AccuFlo AF10 E modulator Disconnect 3 colored tubes from the modulator and the electrical plug from front panel Remove the two screws holding the modulator t...

Страница 10: ... If not the modulator may need to be replaced For further details contact Technical Support If nothing happens when the blast is activated Is the nozzle plugged Remove and inspect Is the PowderGate valve failing to open Contact Technical Support If you suspect the PowderGate valve is not closing completely When the PowderGate valve closes place a finger over the end of the nozzle for 3 seconds Whe...

Страница 11: ...11 tech comcoinc com Electrical Schematic AF10 E Rev 12 7 21 ...

Страница 12: ...12 1 818 841 5500 Pneumatic Schematic AF10 E ...

Страница 13: ...ng but not limited to nozzles powders and attachments not manufactured or supplied by Comco The warranty also does not cover problems resulting from improper or inadequate facilities contaminated air improper power or items that should be expected to wear in normal operation such as nozzles abrasives tubing or fittings This is Comco s only warranty and is in lieu of all other warranties of merchan...

Страница 14: ...Dia MB2520 60 060 Dia MB2599 ComfortGrip handpiece Hi Performance AccuFlo Nozzle Options Fixtured Nozzle 8 32 Set Screw MB1483 3 Quicknut Hi Performance nozzle 375 Recommended 8 32 tapped hole to Ø 1885 hole set screw Abrasive hose Ø 1885 0005 000 MB2520 18 018 Dia MB2520 30 030 Dia The life of your nozzle will depend on the type of abrasive and air pressure you use Check the nozzle for wear on a ...

Отзывы: