13
L1 Clamp N. 1
L2 Clamp N. 2
L3 Clamp N. 3
N Clamp N. 5
Clamp N. 6
ONCE THE ELECTRIC CONNECTION HAS BEEN PERFORMED, THE AUTHORIZED
TECHNICIAN (ELECTRICIAN) MUST ISSUE A DECLARATION CERTIFYING THE
MEASUREMENT OF THE CONTINUITY OF THE EQUIPOTENTIAL PROTECTION
CIRCUIT.
THE APPLIANCE IS TO BE SUPPLIED THROUGH A RESIBASIC CURRENT DEVICE
(RCD) HAVING A RATED RESIBASIC OPERATING CURRENT NOT EXCEEDING 30 MA
TERMINAL BOX
The terminal box is placed externally on the back of the oven.
Oven type
N. of cables
Section (mm²)
Single phase, one chamber
3
4
Single phase, two chambers and versions 9 single
phase
3
6
Three phase one chamber and two chambers
5
4
Three phase from versions 9 and up
5
6
EQUIPOTENTIAL
The equipment must be connected with an equi-potential system . the connection terminal is located near
the terminal box. The bonding wire must have a minimal section of 10 mm ².