C4000-C5000XL O&S Manual
4-11
C4000-OM-EN-08
Suction Filter: (service Interval = 500Hours)
The suction filter, located on the back of the tank as shown in the diagram
below, must be replaced initially after 100 hours and then at intervals of every
500 hours (or 8 months depending on which occurs first)
To replace the Suction Filter:
1. Raise mast before removing suction filter.
2. Loosen and remove the old filter cartridge.
3. Fill the new filter cartridge with hydraulic oil of the same grade as that
already in the tank.
4. Smear some of the oil on the O-ring seal on the top of the filter cartridge
5. Install the new filter cartridge onto the filter housing. Hand tighten the
cartridge into position.
6. Only use a genuine Combilift component
Return Filter: (service Interval = 500 Hours)
The return filter, located on the top of the tank, must be replaced at intervals of
every 500 hours (or 8 months depending on which occurs first).
To replace the Return Filter:
1. Remove the four bolts from the lid of the filter housing in order to gain
access to the filter element.
2. Remove the retaining spring from the top of the filter element
3. Remove the old filter element and replace with the new filter element.
Only use a genuine Combilift component.
4. Fit the retaining spring into the top of the filter element and refit the
housing lid.
Filler Cap
Suction Filter Housing
Suction Filter
Cartridge
Return Filter housing
Hydraulic Oil Level
Gauge
Access panel
In Tank Strainer filter
Cartridge
https://www.forkliftpdfmanuals.com/