Combilift Ltd.
C4000-C5000XL O&S Manual
3-6
C4000-OM-EN-08
Loading in Sideward Mode
Retract the mast fully.
Drive the front of the machine as close to the load as possible.
Drive until the machine is at the centre of the load.
Apply parking brake.
Lower/raise the forks to the required height.
Extend mast.
Lift load.
Double fork load if necessary until load is tight against face of forks. (See
section on “double forking”)
Tilt rearward to secure the load.
Raise load above platform height.
Retract mast fully.
Lower forks until load is just above platform height. Rest the load on the
platforms where possible.
Placing a Load in Sideward Mode
Drive the front of the machine as close to the
placing area as possible.
Apply parking brake.
Lower/raise the forks to the required height.
Extend mast.
Lower load.
Tilt forward.
Retract mast fully.
Release parking brake.
Continue to drive in the sideward direction.
Stacking
Slowly approach stack with load
retracted and tilted backwards.
Stop at face of stack, select neutral and
apply parking brake.
Elevate load until clear of stack top.
Operate accelerator pedal to ensure
that engine speed is sufficient to
prevent stalling and to give the required
lifting speed.
Extend mast until load is above the
stack.
Tilt mast to vertical position and lower
load onto stack.
Retract mast fully and lower forks to
150mm (6”) above ground before
moving off.
https://www.forkliftpdfmanuals.com/